Vermont Casting DVRT41 manual Installation Precautions, Conversion Procedure, Logs may be hot

Page 36

DVRT41 Direct Vent Gas Fireplace

4.Remove air shutters from burner pan by removing shutter retaining screw then air shutter. (Fig. 61)

5.For DVRT41 replace only rear air shutter. Natural Gas: Rear air shutter, close half.

Front air shutter, fully open.

LP: Rear air shutter fully open. Front air shutter fully open.

Shutter

Burner Pan

 

Retaining

 

 

 

Screw

 

 

Air

 

 

Shutter

Front View

 

 

CO103

 

 

Fig. 61 Remove air shutter from burner pan.

 

6.Re-install manifold to burner pan.

NOTE: It is not necessary to remove the pilot tube for conversion.

7.Remove pilot hood by lifting up. (Fig. 62)

8.Remove pilot orifice with allen wrench. (Fig. 63)

9.Install conversion pilot orifice.

10.Re-install pilot hood and be sure to align with index tab. Installation is complete.

Pilot Hood

Pilot Bracket

 

 

CO105a

Fig. 62

Remove pilot hood.

 

Index Tab

Allen

 

 

Wrench

Snap Ring

 

 

 

CO106a

Fig. 63

Remove pilot orifice.

 

Fuel Conversion Instructions

Honeywell Comfort Control Valve ONLY

WARNING: The conversion must only be undertaken by a qualified, certified gas appliance installer.

Installation Precautions

Before proceeding, turn control knob on valve to OFF and turn gas supply OFF. Turn OFF any electricity that may be going to the appliance. CAUTION: Logs may be hot!

Conversion Procedure

1.Open bottom grille to gain access to valve. Remove glass door. (Refer to “Window Frame Assembly Removal Section” Page 23, Fig. 46)

2.Remove logs if previously installed. CAUTION:

Logs may be hot!

3.Remove and replace plug on lower right hand side of the valve; Red for LP and blue for NG. (Fig. 64)

 

Motor Top Cap

Piezo Ignitor

 

 

 

 

 

 

 

 

PILOT

OFF

 

 

 

 

 

¥

 

 

 

 

N

 

 

 

 

 

O ¥

 

 

 

LOCAL

REMOTE

 

LED

 

 

 

 

 

 

 

 

 

LED

 

Local/

 

Pilotstat

 

Plug

 

Remote Switch

Knob

 

Antenna

 

 

 

 

 

FP1037

Fig. 64

Comfort control valve.

 

 

 

4.Remove motor top cap. Depress and turn center plunger until arrow points to correct screw. Red for LP and Blue for NG. NOTE: Plunger will “snap” into NG position when arrow is close to blue screw. It will not “snap” at LP (Red) position. (Fig. 65)

5.Remove manifold mounting screw. (Fig. 66)

6.Remove burner orifice from manifold assembly using 7/16” wrench. (Fig. 67)

7.Install conversion orifice in place of orifice just removed. Refer to Table 2.

8.Remove both air shutters from burner pan by removing air shutter retaining screw then air shutter. (Fig. 68)

9.Install conversion air shutters on burner pan. Re- place air shutter retaining screw. Adjust both air shutters. Refer to Table 3 for proper air shutter adjustment. Secure air shutter retaining screw.

36

10006740

Image 36
Contents Direct Vent Model DVRT41 Table of Contents Installation & Operating Instructions Locating Your FireplaceFireplace Dimensions Installed as Top Vent Framing DimensionsFireplace Dimensions Installed as Rear Vent Mantel Chart Clearance to CombustiblesMantels HearthGas Specifications Gas Line InstallationFraming And Finishing Gas Inlet and Manifold PressuresAlternate Switch Location Remote ON/OFF Switch InstallationEB-1 Electrical Box Optional Top Vent Application EB-1 receptacleGeneral Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationCanadian Installations USA InstallationsGeneral Information Assembling Vent Pipes Flex Vent PipesHow to Use the Vent Graph Twist Lock PipesRear Wall Vent Application Rear Wall Vent Installation StepRear Wall Vent Installations Flex Vent Pipe Vertical Sidewall ApplicationTotal angular variation 270 Maximum vent run with elbowsVertical Sidewall Installation Twist Lock Pipe Always install horizontal venting on a level planeVertical Sidewall Installation Flex Vent Pipe StepBelow Grade Installation Vertical Through-the-Roof ApplicationVertical Through-the-Roof Installation Place firestop spacers and secureTypical Roof SupportTypical Ceiling ApplicationSupport Venting Components Operating Instructions Installation of Logs Log Identification ChartBurner Lava Rock Placement Flame & Temperature AdjustmentFlame Characteristics Inspecting the Venting SystemSIT 820 Valve Lighting and Operating Instructions To Turn Off Gas To HeaterLighting & Operating Instructions Lighting InstructionsTurning Off the Gas to the Appliance Shut Off Procedure Transmitter Operation Off ModeOn Manual Mode Instructions for RF Comfort Control ValveDelay Timer Mode Auto ModeFan Override During Auto Mode Change Between F/C Temperature UnitsLED Count Service Action Auto PathLocal Path On PathTroubleshooting Honeywell VS8421 Window Frame Assembly to be Removed Before Service WorkTrouble Shooting the Gas Control System SIT Nova 820 Millivolt ValveTroubleshooting the Gas Control System SIT 822 Valve with a Honeywell Electronic IgniterBurner and Pilot Orifice Conversion Nova SIT820 ValveInstallation Precautions Conversion ProcedureLogs may be hot Depressd and turn center plunger Maintenance Cleaning the Standing Pilot Control SystemLogs May Be HOT Burner and Burner CompartmentDVRT41 DVRT41 DescriptionDVRT41 Fuel Conversion Kits Natural Gas to LP LP to Natural GasOptional Accessories Available FK12 Fan AssemblyFK24 Fan Assembly Hard Direct Wire Hook UpRemote Controls Ceramic Refractory PanelsDecorative Bay Windows Decorative Frame TrimFor Use in Mobile Homes Model DVRT41RMH Conversion Instructions9b.Units with Honeywell valve Limited Lifetime Warranty Efficiency Ratings Model EnerGuide RatingsState % Fireplace Efficiency % Fan-OFF Fan-ON

DVRT41 specifications

The Vermont Casting DVRT41 is a remarkable gas fireplace that harmoniously combines contemporary aesthetics with advanced heating technology. Designed to enhance any living space, the DVRT41 stands out with its impressive features and functionality, making it a popular choice for those looking to elevate their home environment.

One of the most notable features of the DVRT41 is its efficient heat output. With an impressive BTU range, this fireplace can warm spaces effectively while maintaining low emissions. This efficiency is complemented by Vermont Castings' commitment to sustainability, ensuring that the DVRT41 aligns with environmental considerations.

Aesthetically, the DVRT41 offers a customizable experience. Consumers can choose from various faceplate designs, glass door styles, and finishes to match any décor. The fireplace’s large viewing area provides an unobstructed view of the flames, creating a cozy atmosphere that’s perfect for gatherings or quiet evenings.

The DVRT41 incorporates advanced technologies aimed at maximizing user experience. The fireplace features an intuitive remote control for convenience, allowing users to adjust flame height and heat output easily. This adaptability ensures that homeowners can create the perfect ambiance at any time. The ignition system is designed for reliability and ease, ensuring that starting the fireplace is hassle-free, even in challenging conditions.

Safety is a top priority with the DVRT41. The unit includes features such as a safety shut-off system and a tempered glass front to prevent accidental burns. Additionally, the design allows for efficient venting, minimizing the risk of backdraft or buildup of harmful gases.

Maintenance is straightforward, thanks to the unit's design. The DVRT41 is constructed with durable materials that resist corrosion and wear, ensuring longevity and reduced upkeep costs. Regular cleaning is simple, ensuring that the fireplace remains functional and beautiful for years to come.

Overall, the Vermont Casting DVRT41 gas fireplace is not only a source of warmth but also a stunning focal point within any home. Its blend of efficiency, safety, and design flexibility make it a top choice for homeowners seeking an effective heating solution that doesn’t compromise on style or substance. The DVRT41 exemplifies Vermont Castings' commitment to quality, ensuring that every unit delivers exceptional performance and aesthetic appeal.