Vermont Casting DVRT41 manual Lighting and Operating Instructions, To Turn Off Gas To Heater

Page 26

DVRT41 Direct Vent Gas Fireplace

Lighting and Operating Instructions

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING:If you do not follow these instructions exactly, a fire or explosion

may result causing property damage, personal injury or loss of life.

A.This heater has a pilot which must be lit manually. When lighting the pilot follow these instructions exactly.

B.BEFORE LIGHTING smell all around the heater area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any fireplace

Do not touch any electric switch

Do not use any phone in your building

Immediately call your gas supplier from a

neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the Fire Department

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explosion.

D.Do not use this fireplace if any part has been under water. Immediately call a qualified service techni- cian to inspect the heater and to replace any part of the control system and any gas control which has been under water.

Lighting Instructions

1.STOP! Read the safety information above.

2.Turn off all electrical power to the fireplace.

3.For MN/MP/TN/TP appliances ONLY, go on to Step 4. For RN/RP appliances turn the On/Off switch to “OFF” position or set thermostat to lowest level.

4.Open control access panel.

5.Push in gas control knob slightly and turn

clockwise to "OFF".

 

 

 

 

PILOT

OFF

 

 

 

 

PILOT

 

 

1

 

 

t

 

F

 

 

 

 

 

 

o

 

 

ON

ON

P

 

 

F

 

 

F

l

 

 

 

 

 

i

 

2

 

 

 

O

 

O

 

 

F

 

 

 

 

 

5

 

3

 

FFO

 

4

 

 

 

 

 

 

 

 

Euro SIT

SIT NOVA

Honeywell

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you do not smell gas, go to the next step.

7.Remove glass door before lighting pilot. (See Glass Frame Removal section).

8.Visibly locate pilot by the main burner.

9.Turn knob on gas control counterclockwise

to "PILOT".

10.Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depress- ing the piezo spark ignitor until a flame appears. Continue to hold the control knob in for about one

(1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

3/8" - 1/2"

If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If after several tries, the pilot will not stay lit, turn the gas control knob to "OFF" and call your service technician or gas supplier.

11.Replace glass door.

12.Turn gas control knob to “ON” position.

13.For RN/RP appliances turn the On/Off switch to “ON” position or set thermostat to desired setting.

14.Turn on all electrical power to the fireplace.

To Turn Off Gas To Heater

1.

Turn the On/Off switch to Off position or set the

3.

Open louvre assembly bottom.

 

thermostat to lowest setting.

4.

Push in gas control knob slightly and turn

2.

Turn off all electric power to the fireplace if

 

clockwise

to "OFF". Do not force.

 

service is to be performed.

5.

Close control access panel.

26

10006740

Image 26
Contents Direct Vent Model DVRT41 Table of Contents Installation & Operating Instructions Locating Your FireplaceFireplace Dimensions Installed as Top Vent Framing DimensionsFireplace Dimensions Installed as Rear Vent Mantels Mantel ChartClearance to Combustibles HearthFraming And Finishing Gas SpecificationsGas Line Installation Gas Inlet and Manifold PressuresEB-1 Electrical Box Alternate Switch LocationRemote ON/OFF Switch Installation Optional Top Vent Application EB-1 receptacleGeneral Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationGeneral Information Assembling Vent Pipes Canadian InstallationsUSA Installations Flex Vent PipesRear Wall Vent Application How to Use the Vent GraphTwist Lock Pipes Rear Wall Vent Installation StepRear Wall Vent Installations Flex Vent Pipe Vertical Sidewall ApplicationTotal angular variation 270 Maximum vent run with elbowsVertical Sidewall Installation Twist Lock Pipe Always install horizontal venting on a level planeVertical Sidewall Installation Flex Vent Pipe StepBelow Grade Installation Vertical Through-the-Roof ApplicationVertical Through-the-Roof Installation Place firestop spacers and secureTypical Roof SupportTypical Ceiling ApplicationSupport Venting Components Operating Instructions Burner Lava Rock Placement Installation of LogsLog Identification Chart Flame & Temperature AdjustmentSIT 820 Valve Flame CharacteristicsInspecting the Venting System Lighting and Operating Instructions To Turn Off Gas To HeaterTurning Off the Gas to the Appliance Lighting & Operating InstructionsLighting Instructions On Manual Mode Shut Off ProcedureTransmitter Operation Off Mode Instructions for RF Comfort Control ValveFan Override During Auto Mode Delay Timer ModeAuto Mode Change Between F/C Temperature UnitsLED Count Service Action Auto PathLocal Path On PathTroubleshooting Honeywell VS8421 Window Frame Assembly to be Removed Before Service WorkTrouble Shooting the Gas Control System SIT Nova 820 Millivolt ValveTroubleshooting the Gas Control System SIT 822 Valve with a Honeywell Electronic IgniterBurner and Pilot Orifice Conversion Nova SIT820 ValveLogs may be hot Installation PrecautionsConversion Procedure Depressd and turn center plunger Logs May Be HOT MaintenanceCleaning the Standing Pilot Control System Burner and Burner CompartmentDVRT41 DVRT41 DescriptionDVRT41 Fuel Conversion Kits Natural Gas to LP LP to Natural GasFK24 Fan Assembly Optional Accessories AvailableFK12 Fan Assembly Hard Direct Wire Hook UpDecorative Bay Windows Remote ControlsCeramic Refractory Panels Decorative Frame TrimFor Use in Mobile Homes Model DVRT41RMH Conversion Instructions9b.Units with Honeywell valve Limited Lifetime Warranty State % Fireplace Efficiency % Fan-OFF Fan-ON Efficiency RatingsModel EnerGuide Ratings

DVRT41 specifications

The Vermont Casting DVRT41 is a remarkable gas fireplace that harmoniously combines contemporary aesthetics with advanced heating technology. Designed to enhance any living space, the DVRT41 stands out with its impressive features and functionality, making it a popular choice for those looking to elevate their home environment.

One of the most notable features of the DVRT41 is its efficient heat output. With an impressive BTU range, this fireplace can warm spaces effectively while maintaining low emissions. This efficiency is complemented by Vermont Castings' commitment to sustainability, ensuring that the DVRT41 aligns with environmental considerations.

Aesthetically, the DVRT41 offers a customizable experience. Consumers can choose from various faceplate designs, glass door styles, and finishes to match any décor. The fireplace’s large viewing area provides an unobstructed view of the flames, creating a cozy atmosphere that’s perfect for gatherings or quiet evenings.

The DVRT41 incorporates advanced technologies aimed at maximizing user experience. The fireplace features an intuitive remote control for convenience, allowing users to adjust flame height and heat output easily. This adaptability ensures that homeowners can create the perfect ambiance at any time. The ignition system is designed for reliability and ease, ensuring that starting the fireplace is hassle-free, even in challenging conditions.

Safety is a top priority with the DVRT41. The unit includes features such as a safety shut-off system and a tempered glass front to prevent accidental burns. Additionally, the design allows for efficient venting, minimizing the risk of backdraft or buildup of harmful gases.

Maintenance is straightforward, thanks to the unit's design. The DVRT41 is constructed with durable materials that resist corrosion and wear, ensuring longevity and reduced upkeep costs. Regular cleaning is simple, ensuring that the fireplace remains functional and beautiful for years to come.

Overall, the Vermont Casting DVRT41 gas fireplace is not only a source of warmth but also a stunning focal point within any home. Its blend of efficiency, safety, and design flexibility make it a top choice for homeowners seeking an effective heating solution that doesn’t compromise on style or substance. The DVRT41 exemplifies Vermont Castings' commitment to quality, ensuring that every unit delivers exceptional performance and aesthetic appeal.