Initial Installation

QUALIFIED INSTALLERS ONLY

10.Apply a bead of Mill-Pac Black sealant to the top section of the Ø4” (10 cm) by 5” (12.5 cm) flue collar adaptor previously installed into the fireplace flue outlet. Slide the Ø4” (10 cm) flex vent over the flue collar and secure with three (3) sheet metal screws evenly spaced.

11.Place a bead of high temperature silicone on the intake collar of the fireplace, slide the Ø65⁄8” (16.25 cm) flex intake liner over the collar, secure the flex liner with three (3) sheet metal screws evenly spaced.

12.On the outside of the exterior wall, apply a bead of Mill-Pac Black sealant to the Ø4” (10 cm) pipe of the vent terminal. Slide the flex liner onto the vent terminal and secure with three (3) sheet metal screws evenly spaced.

13.Place a bead of high temperature silicone on the intake collar of the vent terminal, slide the Ø65⁄8” (16.25 cm) flex intake liner over the collar, secure the flex liner with three (3) sheet metal screws evenly spaced.

Horizontal Vent Termination

Wall Thimble

Wall Framing

 

Fire Stop

 

Exhaust 4" Flex Pipe

 

Wire Spacers

 

Combusion Air 6 5/8" Flex Pipe

 

Flue Pipe Adaptor

 

Figure 18: Installation of Fireplace Horizontal Vent Kit.

14.Attach the vent terminal to the outside of the house using four (4) wood screws provided.

15.Light the appliance and ensure proper operation.

OTHER APPROVED VENT PARTS:

Table 3: Approved Vent Manufacturers

Manufacturer

Trade Name

Nominal Sizes

 

 

 

American Metal Products

AmeriVent Direct

4” - 6 5/8”

 

 

 

Security Chimneys International LTD

Secure Vent

4” - 6 5/8”

 

 

 

Selkirk Metalbestos

Direct-Temp

4” - 6 5/8”

 

 

 

Simpson Dura-Vent

Direct Vent GS

4” - 6 5/8”

 

 

 

The Ascot fireplace has been tested and certified for use with AMERICAN METAL PRODUCTS “AMERIVENT DIRECT”, SIMPSON DURAVENT TYPE GS PIPE FOR GAS STOVES. SECURITY CHIMNEY’S “SECURE VENT DIRECT VENT SYSTEM” and SELKIRK “DIRECT-TEMP VENT SYSTEM” kits are available for horizontal and vertical venting. When using Simpson Duravent, it is recommended that, before installation, a bead of RTV High Temperature Silicone should be applied to each outer vent joint, and Mil-Pac to each inner joint. When planning an installation, it will be necessary to select the proper length of vent pipe for the particular requirements.

WARNING: Do not mix parts from different vent manufacturers’ systems.

16

Image 16
Contents Installer ConsumerSafety Precautions GeneralTable of Contents Vented GAS Fireplace Heater Ascot DV NG/LPG Codes And ApprovalsThis Enviro Ascot Fireplace Specifications Dimensions of the AscotFor Your Safety Read Completely Before Operating Operating InstructionsComponent Sound & Reason Pilot flameMaintenance And Service SIT Valve on AscotFirebox Removing inner glass doorKit Parts List Conversion Kit InstallationRemoving valve screw Initial Installation Qualified Installers onlyRound Support Vent Termination Restrictions Installation Instructions KIT ComponentsInstallation of Fireplace Horizontal Vent Kit Manufacturer Trade Name Nominal Sizes4DSC Vent Restrictor Setting Cm at top, 11⁄2 3.8 cm at sides, 11⁄2 3.8 cm at bottom Twist-Lock ConnectionInstalling Vent Cap with Vinyl Siding Stand-Off Straight Through Wall Installation Support straps outwards, and push Sections until the height Multi-Story Vent Pipe Installation Installation Wiring DiagramCanadian Installations A. InstallationsVenting of a Fireplace Fitted with the Drafthood Adaptor Spillage TestSpill Switch Replacement Automatic Safety Shut DownOptional Finishing Seal Plate GAS Line Connection To Test Valve PressuresRecommended Thermostat Wire Size Secondary Installation Ascot Burner TrayEmber Placement Installation of Optional Blower Trouble Shooting Problem Possible Cause SolutionParts List Reference Description Part NumberCast Description Reference Cast Description Part Number DiagramParts Warranty To the DealerWarranty Warranty Installation Data Sheet