Enviro VENTED GAS FIREPLACE HEATER owner manual Support straps outwards, and push

Page 22

Initial Installation

QUALIFIED INSTALLERS ONLY

VERTICAL INSTALLATION:

1.Check the instructions for required clearances (air spaces) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, or other nearby combustible surfaces. Do not pack air spaces with insulation.

2. Set the gas appliance in the desired location. Drop a plumb bob down from the ceiling to the position of the appliance flue exit, and mark the location where the vent will penetrate the ceiling. Drill a small hole at this point. Next, drop a plumb bob from the roof to the hole previously drilled in the ceiling, mark the spot where the vent will penetrate the roof. Determine if ceiling joists, roof rafters, or other framing will obstruct the venting system. You may

wish to relocate the appliance, or to offset, to avoid cutting load bearing members.

3.To install the Round Support Box/Wall Thimble in a flat ceiling, cut a 10 inch (25.4 cm) square hole in the ceiling, centered in the hole drilled in Step 2. Frame the hole as shown in Figure 29.

4. Assemble the desired lengths of black pipe and

Vertical

Vent Cap

Storm

Roof

Collar

Truss

Insulation

Ceiling

Rafter

Insulation

Guard

Support

Collar

Minimum

Clearance to

Combustibles

If installed on a carpeted surfacea hearth

is required

Roof Flashing

15 feet (4.57m)

Maximum

Interior Wall Vertical

Surface Venting

Insulation

Exterior

Wall Surface

Figure 28: Wall Framing Hole for Vertical Installation.

elbows necessary to reach from the appliance adapter up through the Round Support Box. Insure that all pipe and elbow connections are in their fully twist-locked position.

5. Cut hole in the roof centered on the small

hole placed in the roof from Step 2. The hole

should be of sufficient size to meet minimum

requirements for Clearance to Combustibles,

as specified. Continue to assemble lengths of

pipe and elbows necessary to reach from the

ceiling support box up through the roof line.

Galvanized pipe and elbows may be utilized in

the attic, as well as above the roof line. The

galvanized finish is desirable above the roof

line, due to the higher corrosion resistance.

6. Once the pipe sections have been joined, and

run up through the hole in the roof, slip an

elbow strap over the exposed sections, bend

Figure 29: Vertical Installation.

the support straps outwards, and push the

22

Image 22
Contents Installer ConsumerSafety Precautions GeneralTable of Contents Vented GAS Fireplace Heater Ascot DV NG/LPG Codes And ApprovalsThis Enviro Ascot Fireplace Specifications Dimensions of the AscotFor Your Safety Read Completely Before Operating Operating InstructionsComponent Sound & Reason Pilot flameMaintenance And Service SIT Valve on AscotFirebox Removing inner glass doorKit Parts List Conversion Kit InstallationRemoving valve screw Initial Installation Qualified Installers onlyRound Support Vent Termination Restrictions Installation Instructions KIT ComponentsInstallation of Fireplace Horizontal Vent Kit Manufacturer Trade Name Nominal Sizes4DSC Vent Restrictor Setting Cm at top, 11⁄2 3.8 cm at sides, 11⁄2 3.8 cm at bottom Twist-Lock ConnectionInstalling Vent Cap with Vinyl Siding Stand-Off Straight Through Wall Installation Support straps outwards, and push Sections until the height Multi-Story Vent Pipe Installation Canadian Installations InstallationWiring Diagram A. InstallationsVenting of a Fireplace Fitted with the Drafthood Adaptor Spillage TestSpill Switch Replacement Automatic Safety Shut DownOptional Finishing Seal Plate GAS Line Connection To Test Valve PressuresRecommended Thermostat Wire Size Secondary Installation Ascot Burner TrayEmber Placement Installation of Optional Blower Trouble Shooting Problem Possible Cause SolutionParts List Reference Description Part NumberCast Description Reference Cast Description Part Number DiagramParts Warranty To the DealerWarranty Warranty Installation Data Sheet