Enviro EG31-118 owner manual Natural Gas Propane Venturi Setting Rear, Component Sound & Reason

Page 7

Operating Instructions

ADJUSTING VENTURI AIR SETTINGS:

There is only one (1) venturi and one (1) air shutter to be adjusted.

When installing the burner top, ensure that the venturi tube is engaged to the air shutter adjustment rod.

Use this small venturi adjustment rod to achieve a proper and efficient flame, shown in Figure 5.

Adjust rod until the flame pattern is similar to Figure #.

Table 1: Venturi Setting.

 

Natural Gas

Propane

 

 

 

Venturi Setting Rear

1/16” min.

3/16” min.

Move the rod located behind the

piezo ignitor to increase or decrease

primary air at the venturi tube.

Figure 5: Venturi Air Setting Rod

BLOWER SPEED:

The blower will come on only when the fireplace is up to temperature (approximately 20 minutes). The speed of the fan can be changed by turning the fan control knob. To turn the blower off, turn the knob COUNTER CLOCKWISE until it “clicks” off.

It is advisable not to operate the blower below 1/3 speed as it puts a strain on the windings of the blower and running the blower at lower speeds could also cause premature fan failure.

NORMAL SOUNDS DURING OPERATION:

 

Table 2: Normal Sounds.

 

 

Component

Sound & Reason

Focus & Fascia

Creaking when heating up or cooling down.

 

 

Burner

Light pop or poof when turned off; this is more common with LP units.

 

 

Temperature Sensor

Clinking when it senses to turn the blower on or off.

 

 

Pilot Flame

Quiet whisper while the pilot flame in on.

 

 

Blower / Fan

Air movement that increase and decreases with the speed of the blower. The

 

blower is pushing the heat from the fireplace into the room.

 

 

Gas Control Valve

Dull click when turning on or off, this is the valve opening and closing.

 

 

7

Image 7
Contents Focus General Safety PrecautionsTable of Contents This Enviro Focus Fireplace Codes And ApprovalsDimensions SpecificationsOperating Instructions For Your Safety Read Before OperatingComponent Sound & Reason Natural Gas Propane Venturi Setting RearTop bolts for glass door Maintenance And ServiceEnsuring that wires and gas lines are Conversion Kit Installation Kit Parts ListWay, and snap into place Removing valve Screw Minimum fireplace size Width 34 86.36 cm Height 21 53.3 cm Initial InstallationQualified Installers only Installation of Leveling Legs Option 2 Standard Surround Panel Surround Panel installationConverting To a BV Fireplace Parts required for conversionVenting Fireplace Inserts Electrical Requirements To Test Valve Pressures Gas Line ConnectionFocus burner Secondary InstallationBrick Panel Installation Problem Possible Cause Solution Trouble ShootingReference Number Part Description Part Number Parts List ComponentsParts List Components Body Reference Number Part Description Part Number Parts List Surrounds & FasciaParts Diagram Surrounds & Fascia Parts List Cast Parts List Cast Parts Diagram- Cast Bay Front To the Distributor WarrantyInstallation Data Sheet