Enviro EG31-118 owner manual Venting Fireplace Inserts

Page 17

Initial Installation

QUALIFIED INSTALLERS ONLY

VENTING FIREPLACE INSERTS:

The ENVIRO FOCUS may be installed and vented into any solid fuel fireplace that has been installed in accordance with the National, Provincial/State and local building codes and has been constructed of non-combustible materials.

An approved chimney liner and rain cap must be used. A throat connector or flashing must be installed to ensure a tight seal, top performance, safety and efficiency. Carefully follow the manufacturer’s instructions which accompany the chimney liner kit.

Remove the vent collar plate from the top of the insert and connect it securely with sheet metal screws and/or hose clamps. Check for any tears in the liner at this point.

IMPORTANT: The screws that hold the vent collar plate in its approved position must be installed.

Install sealed throat connector or flashing to prevent leakage of room air up through chimney.

DV Only: Before installing vent

liners, mark each liner on both

ends to designate which is the intake and the exhaust.

Measure the height of the chimney before hand and purchase the appropriate kit. Never attempt to over-stretch a flexible liner to accommodate the height of the chimney.

 

Any flue damper must be removed

 

or blocked permanently in the open

 

position.

 

The chimney must be clean, in

 

good working order and constructed

 

of non-combustible materials.

 

Make sure that all chimney

 

cleanouts are tightly fitting and will

 

not permit air to leak into the

�� �����

chimney

�� �����

Figure 23: Installation of Focus DV and BV.

17

Image 17
Contents Focus General Safety PrecautionsTable of Contents This Enviro Focus Fireplace Codes And ApprovalsDimensions SpecificationsOperating Instructions For Your Safety Read Before OperatingComponent Sound & Reason Natural Gas Propane Venturi Setting RearTop bolts for glass door Maintenance And ServiceEnsuring that wires and gas lines are Way, and snap into place Kit Parts ListConversion Kit Installation Removing valve Screw Minimum fireplace size Width 34 86.36 cm Height 21 53.3 cm Initial InstallationQualified Installers only Installation of Leveling Legs Option 2 Standard Surround Panel Surround Panel installationConverting To a BV Fireplace Parts required for conversionVenting Fireplace Inserts Electrical Requirements To Test Valve Pressures Gas Line ConnectionFocus burner Secondary InstallationBrick Panel Installation Problem Possible Cause Solution Trouble ShootingReference Number Part Description Part Number Parts List ComponentsParts List Components Body Reference Number Part Description Part Number Parts List Surrounds & FasciaParts Diagram Surrounds & Fascia Parts List Cast Parts List Cast Parts Diagram- Cast Bay Front To the Distributor WarrantyInstallation Data Sheet