Avalon Stoves 21 DV Fireplace Gas Line Requirements, Gas Line Location, Fuel, Gas Line Connection

Page 12

12

Installation (for qualified installers only)

Gas Line Requirements

MASSACHUSETTS INSTALLATIONS - WARNING:

THIS PRODUCT MUST BE INSTALLED BY A LICENSED PLUYMBER OR GAS FITTER WHEN INSTALLED WITHIN THE COMMONWEALTH OF MASSACHUSETTS.

OTHER MASSACHUSETTS CODE REQUIREMENTS:

Flexible connector must not be longer than 36 inches.

Shutoff valve must be a “T” handle gas cock.

Only direct vent sealed combustion products are approved for bedrooms or bathrooms.

Fireplace dampers must be removed or welded in the open position prior to the installation of a fireplace insert or gas log.

The gas line must be installed in accordance with all local codes, if any; if not, follow ANSI 223.1 and the requirements listed below.

The fireplace and gas control valve must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1/2 psig. For pressures under 1/2 psig, isolate the gas supply piping by closing the manual shutoff valve.

Leak test all gas line joints and the gas control valve prior to and after starting the fireplace.

Gas Line Location

The gas inlet is located on the left side. Line Location” on the following page).

The left side gas inlet is located 2-3/4" above the base of the fireplace.

4"

It may be re-located to the base of the fireplace (see “Optional Gas

 

Gas Line

The base mount gas

(1/2" M.P.T.)

1/2" F.P.T.

inlet is flush with the

 

base of the fireplace.

 

4-1/4"

8-1/4"

 

NOTE: a 3" diameter hole is required to provide

1/2" F.P.T.

clearance for the gas inlet screws.

 

Gas Line (1/2" M.P.T.)

Fuel

This fireplace is designed either for natural gas or for propane (but not for both). Check the sticker on the top of the gas control valve to make sure the correct fuel is used (see illustration on page 4).

Gas Line Connection

Installation must be performed by a qualified installer, service agency or the gas supplier (In Massachusetts a licensed plumber/gasfitter).

Gas Inlet Pressure

 

Standard Input Pressure

 

 

Natural Gas

7" W.C. (1.74 kPA)

Propane

13" W.C. (2.73 kPA)

If the pressure is not sufficient, make sure the piping used is large enough, the supply regulator is adequately adjusted, and the total gas load for the residence does not exceed the amount supplied.

The supply regulator (the regulator that attaches directly to the residence inlet or to the propane tank) should supply gas at the suggested input pressure listed above. Contact the local gas supplier if the regulator is at an improper pressure.

© Travis Industries

4040830

100-01143

Image 12
Contents DV Fireplace 2Introduction Introduction Important InformationTable of Contents Safety Precautions If YOU Smell GASDo not place anything inside Features Installation Options Heating SpecificationsDimensions Installation for qualified installers only Installation WarningsPacking List Additional Items RequiredInstallation Overview Recommended Installation ProcedureFireplace Placement Requirements Minimum Framing DimensionsClearances Nailing Brackets To 1 FacingCorner Installations Raised FireplacesGas Line Requirements Gas Line LocationFuel Gas Line ConnectionElectrical Connection Optional Gas Line LocationElectrical Line Location Electrical Line Connection Optional Electrical Line LocationVent Requirements Vent ClearancesAltitude Considerations Approved VentVent Installation Vertical Vent RequirementsApproved Vent Configurations Restrictor PositionMeasuring Vent Lengths Vent Configurations with Vertical Termination Feet Min 5 feet 5feet 10feetVent Configurations with Horizontal Terminations Termination Requirements Hearth Requirements Floor Mounted FireplacesFace Dimensions Facing RequirementsFacing Under 1 Thick Facing Over 1 ThickFacing Fireplace Details Facing Detail Drywall Facing Top View Drywall FacingFacing Detail Tile Facing View Tile FacingFacing Detail -Facing Over 1 Thick Brick Arched Face Thick Facing Template 225-20040Mantel Requirements Finalizing the Installation Glass Frame Removal and InstallationFinalizing the Installation Log Set Installation Step a Rear Log InstallationStep B Twig, Vertical Log, and Ember Installation Preparing the Rock WoolSteps for Finalizing the Installation Air Shutter AdjustmentPilot Flame Inspection Fine Tuning the EMBER-FYRE Burner Face Installation and Removal Plated SurfacesOperation35 Before You BeginLocation of Controls 36Operation Starting The Pilot FlameAdjusting the Flame Height Operation37Starting the Fireplace for the First Time Turning the Fireplace On and OffAdjusting the Blower Speed 38OperationNormal Operating Sounds Normal Operating OdorsMaintenance39 Yearly Service ProcedureMaintaining Your Fireplaces Appearance 40Maintenance Troubleshooting TableMaintenance41 How this Fireplace WorksWhat Turns the Main Burners On and Off What Prevents Gas Buildup42Maintenance Wiring DiagramReplacement Parts List Safety Label Listing Label44Warranty Years 1 & 2 Coverage Parts & LaborOptional Equipment for qualified installers only LP Conversion InstructionsOptional Equipment for qualified installers only Unscrewed gas will come out of this port. Clockwise Firebox Liner Optional Equipment for qualified installers only Index

21 DV Fireplace specifications

The Avalon Stoves 21 DV Fireplace is a standout fixture in modern heating solutions, blending style and functionality seamlessly. Designed to provide both warmth and aesthetic appeal, this fireplace is perfect for contemporary living spaces.

One of the main features of the Avalon 21 DV is its direct vent technology, which allows for efficient heating while ensuring optimal air quality. The direct vent system utilizes outside air for combustion, minimizing indoor air pollution. This technology not only enhances safety but also improves the overall efficiency of the fireplace, allowing it to produce more heat with less fuel.

Another impressive characteristic of the Avalon 21 DV is its impressive heat output. The unit can deliver up to 25,000 BTUs, effectively warming spaces of up to 1,200 square feet. This makes it an ideal choice for both small and medium-sized rooms. The adjustable flame control allows users to customize their heating experience, providing the flexibility to create a cozy ambiance or a more intense fire as needed.

The design of the Avalon Stoves 21 DV is equally remarkable. With its sleek, modern lines and various finishing options, it easily complements any decor. The large viewing window provides an unobstructed view of the flames, allowing for an inviting atmosphere. Available in several finishes, including black, bronze, and pewter, homeowners can choose a look that best fits their style.

In addition to its aesthetic appeal, the Avalon 21 DV includes several innovative features aimed at enhancing user convenience. The fireplace comes equipped with a programmable remote control, allowing users to adjust settings without leaving their seat. Additionally, the easy-to-use touchscreen interface provides intuitive controls for adjusting heat, flame height, and fan speed.

The Avalon Stoves 21 DV also prioritizes easy maintenance. The unit's design minimizes creosote build-up, simplifying the cleaning process. The external venting system allows for straightforward installation, which can expand the possible locations for placement in a home.

In conclusion, the Avalon Stoves 21 DV Fireplace merges modern design with advanced technology, making it an excellent choice for those seeking an efficient heating solution that doesn't compromise on style. With its direct vent technology, impressive heat output, and user-friendly features, this fireplace not only enhances comfort but also elevates the overall aesthetic of any room.