Avalon Stoves 21 DV Fireplace manual Termination Requirements

Page 20

20

Installation (for qualified installers only)

Termination Requirements

NOTE: Measure all clearances from the nearest edge of the exhaust hood.

A

Minimum 9" clearance from any door or window

Roof

Surface

B

Minimum 12" above any grade, veranda, porch, deck or balcony

 

C

Minimum 3-3/8" from outside corner walls

11” Min.

Roof

D

Minimum 0" from inside corner walls

6” Min. Eaves

 

EMinimum 11" clearance below unventilated soffits or roof surfaces

Minimum 18" clearance below ventilated soffits

Minimum 6" clearance from roof eaves

NOTE: Vinyl surfaces require 24"

FMinimum 18" clearance below a veranda, porch, deck or balcony (must have two open sides)

GMinimum 48" clearance from any adjacent building

HMinimum 84" clearance above any grade when adjacent to public walkways or driveways NOTE: may not be used over a walkway or driveway shared by an adjacent building

IMinimum 48" clearance from any mechanical air supply inlet

JMinimum 36" clearance above and 48” below and to the sides of non-mechanical air supply inlet

KMinimum 36" from the area above the meter/regulator (vent outlet)

L Minimum 36" from the meter/regulator (vent outlet)

M Minimum 12” above the roof line (for vertical terminations)

NMinimum 24” horizontal clearance to any surface (such as an exterior wall) – for vertical terminations

E

N

M

E

A

K

G A

F

D C I

L

B

NOTE: Measure clearances to the nearest edge of the exhaust hood.

E

J

H

Use the vinyl siding standoff (#950) when installing on an exterior with vinyl siding.

Vent termination must not be located where it will become plugged by snow or other material.

Venting termination shall not be recessed into a wall or siding.

These clearances meet UMC-1994 code standards.

© Travis Industries

4040830

100-01143

Image 20
Contents DV Fireplace 2Introduction Introduction Important InformationTable of Contents Safety Precautions If YOU Smell GASDo not place anything inside Dimensions Features Installation OptionsHeating Specifications Installation for qualified installers only Installation WarningsPacking List Additional Items RequiredInstallation Overview Recommended Installation ProcedureClearances Fireplace Placement RequirementsMinimum Framing Dimensions Nailing Brackets To 1 FacingCorner Installations Raised FireplacesGas Line Requirements Gas Line LocationFuel Gas Line ConnectionElectrical Line Location Electrical ConnectionOptional Gas Line Location Electrical Line Connection Optional Electrical Line LocationVent Requirements Vent ClearancesAltitude Considerations Approved VentVent Installation Vertical Vent RequirementsMeasuring Vent Lengths Approved Vent ConfigurationsRestrictor Position Vent Configurations with Vertical Termination Feet Min 5 feet 5feet 10feetVent Configurations with Horizontal Terminations Termination Requirements Hearth Requirements Floor Mounted FireplacesFace Dimensions Facing RequirementsFacing Under 1 Thick Facing Over 1 ThickFacing Fireplace Details Facing Detail Drywall Facing Top View Drywall FacingFacing Detail Tile Facing View Tile FacingFacing Detail -Facing Over 1 Thick Brick Arched Face Thick Facing Template 225-20040Mantel Requirements Finalizing the Installation Glass Frame Removal and InstallationFinalizing the Installation Log Set Installation Step a Rear Log InstallationStep B Twig, Vertical Log, and Ember Installation Preparing the Rock WoolPilot Flame Inspection Steps for Finalizing the InstallationAir Shutter Adjustment Fine Tuning the EMBER-FYRE Burner Face Installation and Removal Plated SurfacesLocation of Controls Operation35Before You Begin 36Operation Starting The Pilot FlameAdjusting the Flame Height Operation37Starting the Fireplace for the First Time Turning the Fireplace On and OffAdjusting the Blower Speed 38OperationNormal Operating Sounds Normal Operating OdorsMaintaining Your Fireplaces Appearance Maintenance39Yearly Service Procedure 40Maintenance Troubleshooting TableMaintenance41 How this Fireplace WorksWhat Turns the Main Burners On and Off What Prevents Gas BuildupReplacement Parts List 42MaintenanceWiring Diagram Safety Label Listing Label44Warranty Years 1 & 2 Coverage Parts & LaborOptional Equipment for qualified installers only LP Conversion InstructionsOptional Equipment for qualified installers only Unscrewed gas will come out of this port. Clockwise Firebox Liner Optional Equipment for qualified installers only Index

21 DV Fireplace specifications

The Avalon Stoves 21 DV Fireplace is a standout fixture in modern heating solutions, blending style and functionality seamlessly. Designed to provide both warmth and aesthetic appeal, this fireplace is perfect for contemporary living spaces.

One of the main features of the Avalon 21 DV is its direct vent technology, which allows for efficient heating while ensuring optimal air quality. The direct vent system utilizes outside air for combustion, minimizing indoor air pollution. This technology not only enhances safety but also improves the overall efficiency of the fireplace, allowing it to produce more heat with less fuel.

Another impressive characteristic of the Avalon 21 DV is its impressive heat output. The unit can deliver up to 25,000 BTUs, effectively warming spaces of up to 1,200 square feet. This makes it an ideal choice for both small and medium-sized rooms. The adjustable flame control allows users to customize their heating experience, providing the flexibility to create a cozy ambiance or a more intense fire as needed.

The design of the Avalon Stoves 21 DV is equally remarkable. With its sleek, modern lines and various finishing options, it easily complements any decor. The large viewing window provides an unobstructed view of the flames, allowing for an inviting atmosphere. Available in several finishes, including black, bronze, and pewter, homeowners can choose a look that best fits their style.

In addition to its aesthetic appeal, the Avalon 21 DV includes several innovative features aimed at enhancing user convenience. The fireplace comes equipped with a programmable remote control, allowing users to adjust settings without leaving their seat. Additionally, the easy-to-use touchscreen interface provides intuitive controls for adjusting heat, flame height, and fan speed.

The Avalon Stoves 21 DV also prioritizes easy maintenance. The unit's design minimizes creosote build-up, simplifying the cleaning process. The external venting system allows for straightforward installation, which can expand the possible locations for placement in a home.

In conclusion, the Avalon Stoves 21 DV Fireplace merges modern design with advanced technology, making it an excellent choice for those seeking an efficient heating solution that doesn't compromise on style. With its direct vent technology, impressive heat output, and user-friendly features, this fireplace not only enhances comfort but also elevates the overall aesthetic of any room.