Installation (for qualified installers only)

Installation Overview

All requirements below must be met.

See the section "Termination Requirements"

See the section "Vent Requirements"

Thermostat Wire (either side)

Gas Line

(left side or beneath)

Drywall

See the section "Minimum Framing Dimensions"

See the section "Mantel Requirements"

Non-combustible facing (see the section "Facing Requirements")

See the section "Electrical Connection"

Insulation or drywall must not fill the 1/2" gap around the sides of the fireplace.

See the section "Hearth Requirements"

1" Min. Clearance from Face to Side Wall

Recommended Installation Procedure

1.Frame the opening for the fireplace. Make sure to allow for vent installation.

2.If the facing is 1/2" or 7/8" thick (most common), secure the fireplace to the framing with the nailing brackets (see "Nailing Brackets" for details).

NOTE: If the facing is not 1/2" or 7/8" thick, follow the directions below:

Place a strip of facing material to both sides of the fireplace opening (NOTE: the strips will be removed after the fireplace is secured). The facing thickness must represent the total thickness of the finished facing (e.g.: If tile is to be used, include the thickness of the backboard, tile, and tile adhesive). Insert the fireplace into the framing. Slide it back until the front edge of the nailing brackets are flush with the facing material. Secure the fireplace using the plates located along the base of the fireplace.

3.Complete the gas line installation.

4.Complete the electrical hook-up.

5.Complete the vent installation.

6.Install the hearth (if applicable).

7.Install the facing.

8.Install the mantel (if applicable).

© Travis Industries

4040830

100-01143

Image 8
Contents DV Fireplace 2Introduction Introduction Important InformationTable of Contents Safety Precautions If YOU Smell GASDo not place anything inside Dimensions Features Installation OptionsHeating Specifications Installation for qualified installers only Installation WarningsPacking List Additional Items RequiredInstallation Overview Recommended Installation ProcedureClearances Fireplace Placement RequirementsMinimum Framing Dimensions Nailing Brackets To 1 FacingCorner Installations Raised FireplacesGas Line Requirements Gas Line LocationFuel Gas Line ConnectionElectrical Line Location Electrical ConnectionOptional Gas Line Location Electrical Line Connection Optional Electrical Line LocationVent Requirements Vent ClearancesAltitude Considerations Approved VentVent Installation Vertical Vent RequirementsMeasuring Vent Lengths Approved Vent ConfigurationsRestrictor Position Vent Configurations with Vertical Termination Feet Min 5 feet 5feet 10feetVent Configurations with Horizontal Terminations Termination Requirements Hearth Requirements Floor Mounted FireplacesFace Dimensions Facing RequirementsFacing Under 1 Thick Facing Over 1 ThickFacing Fireplace Details Facing Detail Drywall Facing Top View Drywall FacingFacing Detail Tile Facing View Tile FacingFacing Detail -Facing Over 1 Thick Brick Arched Face Thick Facing Template 225-20040Mantel Requirements Finalizing the Installation Glass Frame Removal and InstallationFinalizing the Installation Log Set Installation Step a Rear Log InstallationStep B Twig, Vertical Log, and Ember Installation Preparing the Rock WoolPilot Flame Inspection Steps for Finalizing the InstallationAir Shutter Adjustment Fine Tuning the EMBER-FYRE Burner Face Installation and Removal Plated SurfacesLocation of Controls Operation35Before You Begin 36Operation Starting The Pilot FlameAdjusting the Flame Height Operation37Starting the Fireplace for the First Time Turning the Fireplace On and OffAdjusting the Blower Speed 38OperationNormal Operating Sounds Normal Operating OdorsMaintaining Your Fireplaces Appearance Maintenance39Yearly Service Procedure 40Maintenance Troubleshooting TableMaintenance41 How this Fireplace WorksWhat Turns the Main Burners On and Off What Prevents Gas BuildupReplacement Parts List 42MaintenanceWiring Diagram Safety Label Listing Label44Warranty Years 1 & 2 Coverage Parts & LaborOptional Equipment for qualified installers only LP Conversion InstructionsOptional Equipment for qualified installers only Unscrewed gas will come out of this port. Clockwise Firebox Liner Optional Equipment for qualified installers only Index

21 DV Fireplace specifications

The Avalon Stoves 21 DV Fireplace is a standout fixture in modern heating solutions, blending style and functionality seamlessly. Designed to provide both warmth and aesthetic appeal, this fireplace is perfect for contemporary living spaces.

One of the main features of the Avalon 21 DV is its direct vent technology, which allows for efficient heating while ensuring optimal air quality. The direct vent system utilizes outside air for combustion, minimizing indoor air pollution. This technology not only enhances safety but also improves the overall efficiency of the fireplace, allowing it to produce more heat with less fuel.

Another impressive characteristic of the Avalon 21 DV is its impressive heat output. The unit can deliver up to 25,000 BTUs, effectively warming spaces of up to 1,200 square feet. This makes it an ideal choice for both small and medium-sized rooms. The adjustable flame control allows users to customize their heating experience, providing the flexibility to create a cozy ambiance or a more intense fire as needed.

The design of the Avalon Stoves 21 DV is equally remarkable. With its sleek, modern lines and various finishing options, it easily complements any decor. The large viewing window provides an unobstructed view of the flames, allowing for an inviting atmosphere. Available in several finishes, including black, bronze, and pewter, homeowners can choose a look that best fits their style.

In addition to its aesthetic appeal, the Avalon 21 DV includes several innovative features aimed at enhancing user convenience. The fireplace comes equipped with a programmable remote control, allowing users to adjust settings without leaving their seat. Additionally, the easy-to-use touchscreen interface provides intuitive controls for adjusting heat, flame height, and fan speed.

The Avalon Stoves 21 DV also prioritizes easy maintenance. The unit's design minimizes creosote build-up, simplifying the cleaning process. The external venting system allows for straightforward installation, which can expand the possible locations for placement in a home.

In conclusion, the Avalon Stoves 21 DV Fireplace merges modern design with advanced technology, making it an excellent choice for those seeking an efficient heating solution that doesn't compromise on style. With its direct vent technology, impressive heat output, and user-friendly features, this fireplace not only enhances comfort but also elevates the overall aesthetic of any room.