Installation (for qualified installers only)

Facing Requirements

NOTE: The combustible area above the facing must not protrude more than 3/4" from the facing. If it does, it is considered a mantel and must meet the mantel requirements listed in this manual.

Face Dimensions

Face

Height

Width

Bottom of Face

Installation Notes

 

 

 

 

 

Arched Faces

35-1/2”

21-1/8”

Flush w base of fireplace

Arched top is 25-3/4” radius

Bungalow, T. of L.

35-3/8”

21-1/8”

Flush w base of fireplace

 

Vict. Lace

35-1/2”

21-1/8”

Flush w base of fireplace

 

Looking Glass

36-3/4”

23-1/2”

1-1/4” BELOW base of fireplace

Cast face is approx. 2” thick

 

 

 

 

 

Wilmington

36-3/4”

22-1/8”

1-1/4” BELOW base of fireplace

 

 

 

 

 

 

Facing Under 1” Thick

Any material that protrudes more than 3/4” in front of the facing is considered a mantel and must meet the mantel requirements in this manual.

NOTE: The facing tucks behind the flanges.

4-3/4”

3-3/8”

30-1/4”

(approx.)

The facing (combustible or non-combustible) must maintain a 1/2” clearance to the sides

c

Recommended Order of Installation We recommend installing the facing (drywall, tile) under the notch at the front of the fireplace (“a”) - then install the sides and top (“b” and “c”)

a

b

and top of the fireplace.

NOTE The facing tucks under the notch at the front of the fireplace (3/8” above the base of the fireplace).

Facing Over 1” Thick

Facing that protrudes in front of the face above the face (or within 1/2” of each side) must be made of non-combustible materials.

NOTE A 3/8" gap above the face is required for face installation and removal.

© Travis Industries

4040830

100-01143

Image 22
Contents DV Fireplace 2Introduction Introduction Important InformationTable of Contents Safety Precautions If YOU Smell GASDo not place anything inside Heating Specifications Features Installation OptionsDimensions Packing List Installation for qualified installers onlyInstallation Warnings Additional Items RequiredInstallation Overview Recommended Installation ProcedureMinimum Framing Dimensions Fireplace Placement RequirementsClearances Nailing Brackets To 1 FacingCorner Installations Raised FireplacesFuel Gas Line RequirementsGas Line Location Gas Line ConnectionOptional Gas Line Location Electrical ConnectionElectrical Line Location Electrical Line Connection Optional Electrical Line LocationAltitude Considerations Vent RequirementsVent Clearances Approved VentVent Installation Vertical Vent RequirementsRestrictor Position Approved Vent ConfigurationsMeasuring Vent Lengths Vent Configurations with Vertical Termination Feet Min 5 feet 5feet 10feetVent Configurations with Horizontal Terminations Termination Requirements Hearth Requirements Floor Mounted FireplacesFacing Under 1 Thick Face DimensionsFacing Requirements Facing Over 1 ThickFacing Fireplace Details Facing Detail Drywall Facing Top View Drywall FacingFacing Detail Tile Facing View Tile FacingFacing Detail -Facing Over 1 Thick Brick Arched Face Thick Facing Template 225-20040Mantel Requirements Finalizing the Installation Glass Frame Removal and InstallationFinalizing the Installation Log Set Installation Step a Rear Log InstallationStep B Twig, Vertical Log, and Ember Installation Preparing the Rock WoolAir Shutter Adjustment Steps for Finalizing the InstallationPilot Flame Inspection Fine Tuning the EMBER-FYRE Burner Face Installation and Removal Plated SurfacesBefore You Begin Operation35Location of Controls 36Operation Starting The Pilot FlameStarting the Fireplace for the First Time Adjusting the Flame HeightOperation37 Turning the Fireplace On and OffNormal Operating Sounds Adjusting the Blower Speed38Operation Normal Operating OdorsYearly Service Procedure Maintenance39Maintaining Your Fireplaces Appearance 40Maintenance Troubleshooting TableWhat Turns the Main Burners On and Off Maintenance41How this Fireplace Works What Prevents Gas BuildupWiring Diagram 42MaintenanceReplacement Parts List Safety Label Listing Label44Warranty Years 1 & 2 Coverage Parts & LaborOptional Equipment for qualified installers only LP Conversion InstructionsOptional Equipment for qualified installers only Unscrewed gas will come out of this port. Clockwise Firebox Liner Optional Equipment for qualified installers only Index

21 DV Fireplace specifications

The Avalon Stoves 21 DV Fireplace is a standout fixture in modern heating solutions, blending style and functionality seamlessly. Designed to provide both warmth and aesthetic appeal, this fireplace is perfect for contemporary living spaces.

One of the main features of the Avalon 21 DV is its direct vent technology, which allows for efficient heating while ensuring optimal air quality. The direct vent system utilizes outside air for combustion, minimizing indoor air pollution. This technology not only enhances safety but also improves the overall efficiency of the fireplace, allowing it to produce more heat with less fuel.

Another impressive characteristic of the Avalon 21 DV is its impressive heat output. The unit can deliver up to 25,000 BTUs, effectively warming spaces of up to 1,200 square feet. This makes it an ideal choice for both small and medium-sized rooms. The adjustable flame control allows users to customize their heating experience, providing the flexibility to create a cozy ambiance or a more intense fire as needed.

The design of the Avalon Stoves 21 DV is equally remarkable. With its sleek, modern lines and various finishing options, it easily complements any decor. The large viewing window provides an unobstructed view of the flames, allowing for an inviting atmosphere. Available in several finishes, including black, bronze, and pewter, homeowners can choose a look that best fits their style.

In addition to its aesthetic appeal, the Avalon 21 DV includes several innovative features aimed at enhancing user convenience. The fireplace comes equipped with a programmable remote control, allowing users to adjust settings without leaving their seat. Additionally, the easy-to-use touchscreen interface provides intuitive controls for adjusting heat, flame height, and fan speed.

The Avalon Stoves 21 DV also prioritizes easy maintenance. The unit's design minimizes creosote build-up, simplifying the cleaning process. The external venting system allows for straightforward installation, which can expand the possible locations for placement in a home.

In conclusion, the Avalon Stoves 21 DV Fireplace merges modern design with advanced technology, making it an excellent choice for those seeking an efficient heating solution that doesn't compromise on style. With its direct vent technology, impressive heat output, and user-friendly features, this fireplace not only enhances comfort but also elevates the overall aesthetic of any room.