Avalon Stoves 21 DV Fireplace manual Unscrewed gas will come out of this port. Clockwise

Page 47

Optional Equipment (for qualified installers only)

47

5Install the logs and embers.

6Replace glass and face.

7Remove the regulator from the front of the gas control valve. Replace with the propane regulator, using the new gasket and screws included with the regulator. NOTE:

Leak test this area after the heater is installed, gas is connected, and the main burner is lit.

a

Remove and discard the three screws using a slotted screwdriver of Torx T-20.

b

Remove and discard the regulator, diaphram, spring and center post.

Slotted

Screwdriver

(or T-20 Torx)

c

Install the LP regulator. Use the screws included with the LP regulator. Tighten to approximately 25 Lbs. torque.

NOTE: Make sure the regulator gasket is correctly aligned before installation.

Slotted

Screwdriver

(or T-20 Torx)

d

Place the LP label on top of the control cover near the gas control valve.

9Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly leak-test all gas connections and the gas control valve. Check the pilot. Adjust if necessary.

WARNING:

When lighting or re-lighting the pilot, the glass must be removed (see page 28).

To adjust the pilot flame, turn this screw (NOTE: if totally

 

 

The pilot flame must contact the thermocouple and

unscrewed gas will come out of this port). Clockwise

 

 

thermopile (see the illustration below). Adjust the pilot up or

lowers the flame while counter-clockwise raises it.

Standard

down as necessary.

 

 

 

 

 

Screwdriver

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

© Travis Industries

4040830

100-01143

Image 47
Contents DV Fireplace Introduction Important Information 2IntroductionTable of Contents If YOU Smell GAS Safety PrecautionsDo not place anything inside Dimensions Features Installation OptionsHeating Specifications Additional Items Required Installation for qualified installers onlyInstallation Warnings Packing ListRecommended Installation Procedure Installation OverviewClearances Fireplace Placement RequirementsMinimum Framing Dimensions To 1 Facing Nailing BracketsRaised Fireplaces Corner InstallationsGas Line Connection Gas Line RequirementsGas Line Location FuelElectrical Line Location Electrical ConnectionOptional Gas Line Location Optional Electrical Line Location Electrical Line ConnectionApproved Vent Vent RequirementsVent Clearances Altitude ConsiderationsVertical Vent Requirements Vent InstallationMeasuring Vent Lengths Approved Vent ConfigurationsRestrictor Position Feet Min 5 feet 5feet 10feet Vent Configurations with Vertical TerminationVent Configurations with Horizontal Terminations Termination Requirements Floor Mounted Fireplaces Hearth RequirementsFacing Over 1 Thick Face DimensionsFacing Requirements Facing Under 1 ThickFacing Fireplace Details Top View Drywall Facing Facing Detail Drywall FacingView Tile Facing Facing Detail Tile FacingArched Face Thick Facing Template 225-20040 Facing Detail -Facing Over 1 Thick BrickMantel Requirements Glass Frame Removal and Installation Finalizing the InstallationFinalizing the Installation Step a Rear Log Installation Log Set InstallationPreparing the Rock Wool Step B Twig, Vertical Log, and Ember InstallationPilot Flame Inspection Steps for Finalizing the InstallationAir Shutter Adjustment Fine Tuning the EMBER-FYRE Burner Plated Surfaces Face Installation and RemovalLocation of Controls Operation35Before You Begin Starting The Pilot Flame 36OperationTurning the Fireplace On and Off Adjusting the Flame HeightOperation37 Starting the Fireplace for the First TimeNormal Operating Odors Adjusting the Blower Speed38Operation Normal Operating SoundsMaintaining Your Fireplaces Appearance Maintenance39Yearly Service Procedure Troubleshooting Table 40MaintenanceWhat Prevents Gas Buildup Maintenance41How this Fireplace Works What Turns the Main Burners On and OffReplacement Parts List 42MaintenanceWiring Diagram Listing Label Safety LabelYears 1 & 2 Coverage Parts & Labor 44WarrantyLP Conversion Instructions Optional Equipment for qualified installers onlyOptional Equipment for qualified installers only Unscrewed gas will come out of this port. Clockwise Firebox Liner Optional Equipment for qualified installers only Index

21 DV Fireplace specifications

The Avalon Stoves 21 DV Fireplace is a standout fixture in modern heating solutions, blending style and functionality seamlessly. Designed to provide both warmth and aesthetic appeal, this fireplace is perfect for contemporary living spaces.

One of the main features of the Avalon 21 DV is its direct vent technology, which allows for efficient heating while ensuring optimal air quality. The direct vent system utilizes outside air for combustion, minimizing indoor air pollution. This technology not only enhances safety but also improves the overall efficiency of the fireplace, allowing it to produce more heat with less fuel.

Another impressive characteristic of the Avalon 21 DV is its impressive heat output. The unit can deliver up to 25,000 BTUs, effectively warming spaces of up to 1,200 square feet. This makes it an ideal choice for both small and medium-sized rooms. The adjustable flame control allows users to customize their heating experience, providing the flexibility to create a cozy ambiance or a more intense fire as needed.

The design of the Avalon Stoves 21 DV is equally remarkable. With its sleek, modern lines and various finishing options, it easily complements any decor. The large viewing window provides an unobstructed view of the flames, allowing for an inviting atmosphere. Available in several finishes, including black, bronze, and pewter, homeowners can choose a look that best fits their style.

In addition to its aesthetic appeal, the Avalon 21 DV includes several innovative features aimed at enhancing user convenience. The fireplace comes equipped with a programmable remote control, allowing users to adjust settings without leaving their seat. Additionally, the easy-to-use touchscreen interface provides intuitive controls for adjusting heat, flame height, and fan speed.

The Avalon Stoves 21 DV also prioritizes easy maintenance. The unit's design minimizes creosote build-up, simplifying the cleaning process. The external venting system allows for straightforward installation, which can expand the possible locations for placement in a home.

In conclusion, the Avalon Stoves 21 DV Fireplace merges modern design with advanced technology, making it an excellent choice for those seeking an efficient heating solution that doesn't compromise on style. With its direct vent technology, impressive heat output, and user-friendly features, this fireplace not only enhances comfort but also elevates the overall aesthetic of any room.