Breckwell P22I, P22FSL owner manual Smoke Smell or Soot BUILD-UP, High Limit Switch Keeps Tripping

Page 27

TROUBLESHOOTING GUIDE

27

HIGH LIMIT SWITCH KEEPS TRIPPING

Possible Causes:

Possible Remedies:

 

 

 

1.

The convection blower is overheating and tripping the internal

Clean any dust off of the windings and fan blades. If cleaning the

 

temperature shutoff.

 

blower does not help, the blower may be bad.

 

 

 

 

 

2.

The stove is being left on the highest setting for extended

The highest heat level setting is designed for use over short periods

 

periods of time.

of time. Burning the stove on the highest setting for longer than 1 –

 

 

2 hours could lead to potential overheating situations.

 

 

 

3.

Fuel other than wood pellets is being burned in the stove.

Breckwell pellet stoves are designed and tested to use wood pellets.

 

 

While it is possible to burn a corn mixture (corn mixed in with wood

 

 

pellets) in the stove, it is not recommended to burn above the

 

 

number 3 heat level. Check for signs of fuel other than wood

 

 

pellets. If there are signs of corn being used, find out what mixed

 

 

was being used and what setting. No other types of fuel have been

 

 

approved for Breckwell pellet stoves. If there are signs of other

 

 

types of fuel being used, advise the consumer to stop using them

 

 

immediately.

 

 

 

4.

Power surge or brown out situation.

A power surge, spike, or voltage drop could cause the high limit

 

 

switch to trip. Check to see if a surge protector is being used on the

 

 

stove. If not, recommend one to the consumer.

 

 

 

5.

High limit switch is malfunctioning.

If the other items check out ok, replace the high limit switch.

 

 

 

DIGITAL CIRCUIT BOARD TIMING RATES

Heat Level Setting

P22

 

 

1 & 3

1.4 seconds

 

 

1

2 seconds

 

 

1 & 4

2.5 seconds

 

 

2

4 seconds

 

 

3

7 seconds

 

 

4

9 seconds

 

 

Total Cycle Time

14.5 seconds

 

 

SMOKE SMELL OR SOOT BUILD-UP

Because it is a wood-burning device, your Breckwell may emit a faint wood-burning odor. If this increases beyond normal, or if you notice any soot build-up on walls or furniture, check your exhaust system carefully for leaks. All joints should be properly sealed. Also clean your stove, following instructions in “MAINTENANCE”. If problem persists, contact your dealer.

Image 27
Contents Economy Series P22 Important Information IntroductionSafety Precautions Table of Contents Clearances InstallationSpecifications PreparationWhen Outside AIR is not Used Combustion AIR SupplyVenting Horizontally Through Wall refer to Figure Freestanding InstallationsEquivalent Vent Length EVL Assembling Pedestal or LEG SETVertically Into Existing Chimney System Vertically with NEW Chimney System Refer to FigureVertically Into Existing Masonry Fireplace Installation Through Side of Masonry ChimneyAssembling the Flashing SET Insert InstallationsWhen Vent Pipe Extends to Chimney TOP Refer to Figures 16 AS a BUILT-IN Fireplace Chase dimensions shown are minimums and must be maintainedElectrical Installation Special Mobile Home RequirementsCombustion AIR Supply Operation Hotrod Automatic Firestarter Proper FuelPRE-START-UP Check Building a FireRE-STARTING a Warm Stove Breckwell Maintenance ToolShutdown Procedure Safety Features∙ a Millivolt Thermostat is Required Thermostat InstallationThermostat Installation Optional ThermostatPlease Read this ASH Disposal MaintenanceCleaning ASH RemovalBlowers Daily Weekly Annually or per Ton Chimney CleaningTroubleshooting Guide Stove Shuts OFF and the # 2 Light FlashesPossible Causes Stove Shuts OFF and the # 3 Light Flashes Convection Blower Shuts OFF and Comes Back on Stove Feeds PELLETS, but will not Ignite Possible Causes Possible Remedies Smoke Smell Coming Back Into the HomeTroubleshooting Guide Troubleshooting Guide Digital Circuit Board Timing Rates High Limit Switch Keeps TrippingHeat Level Setting P22 Smoke Smell or Soot BUILD-UPElectrical Diagram Burnpot Replacement PartsLifetime Limited Warranty
Related manuals
Manual 29 pages 58.71 Kb