Regency Wraps F2400M, S2400M installation manual Mobile Home Installation

Page 15

INSTALLATION

MOBILE HOME INSTALLATION

Once you have properly marked the position of your unit and the fl oor protection as outlined in the Residential Installation items #1 through #8, a supply of fresh air has to be supplied to your unit. Cut a minimum 4" (102mm) diameter hole through your fl oor protector and the fl oor directly under your pedestal base to the outside. Use 4" (102mm) duct pipe with a mesh grill to pipe fresh air into the pedestal area. Block off the hole in the back of the pedestal with the square plate and the two 1/2" screws provided.

Place your unit in position and secure it to the

oor using two lag bolts 3/8" (10mm) x 3-1/2" (89mm)throughthetwoholesinsidethepedestal base. It is important to maintain the structural integrity of the Mobile Home fl oor, walls and roof when installing your unit.

For Mobile Home units installed in the U.S. the unit must be grounded using a #8 ground wire with approved termination and star washer.

CAUTION: At no time use unlabelled parts, or substitute parts made for another chimney system.

Install as per chimney manufacturer's installation instructions.

WARNING: Operate only with door fully closed - open feed door to feed fire only.

In addition to standard installation instructions the following requirements are mandatory for installation in a mobile home.

1)The stove must be permanently bolted to the fl oor of the Mobile Home using the fl oor screws provided.

2)The stove must have a permanent outside air source for combustion.

3)The stove must be electrically grounded to the steel chassis of the Mobile Home.

4)A listed double-wall connector chimney system, roof thimble, spark arrestor and roof fl ashing kit suitable for use in Mobile Homes must be used.

5)If the chimney exits the Mobile Home at a location other than through the roof, and exits at a point 7ft. (2130mm) or less above the ground level on which the Mobile Home is positioned a guard or method of enclosing the chimney shall be fi tted at the point of exit for a height up to 7ft. (2130mm).

6)The chimney shall be attached directly to the room heater and shall extend at least 3 ft. (914mm) above the part of the roof through which it passes. The top of the chimney should project at least 2ft. (610mm) above the highest elevation of any part of the Mobile Home within 10 ft. (3048mm) of the chimney.

7)The chimney system shall comply with Local Requirements.

8)Any openings in a chimney guard where required must not permit the entrance of 3/4" (19mm) diameter rod.

9)CAUTION: THE STRUCTURALINTEGRITY OF THE MOBILE HOME ROOF, FLOOR, WALLS AND CEILING MUST BE MAIN- TAINED.

10)Check any other local building code as other local codes may apply.

11)WARNING:DONOTINSTALLINASLEEP- ING ROOM OF A MOBILE HOME.

12)Use silicone to create an effective vapour barrier at the location where the chimney or other component penetrates to the exterior of the structure.

Regency Freestanding Woodstove

15

Image 15
Contents 01/18/07 Freestanding WoodstoveModular Parts Regency Fireplace ProductTable of Contents Safety Label for F2400M Safety Label245 Safety Label for S2400MUnit Dimensions InstallationModular Installation Options Residential InstallationResidential Installation C Vent Single Wall Room AIRMinimum Clearance to Combustible Materials Step Stove Minimum Alcove Clearance to Combustible MaterialsFloor Protection Medium S2400M815-555 Stove Assembly Prior to InstallationAirmate Assembly for F2400M S2400M Side Shield AdjustmentLeg and Bottom Shield Assembly STEP-BY-STEP Chimney Connector InstallationMasonry Chimney Masonry FireplaceFactory Built Chimney Method a 12 304.8 mm Clearance to Combustible Wall Member Combustible Wall Chimney Connector PASS-THROUGHSExample b Recommended Heights for Woodstove FlueRecommended Flue Height Elevation Example aMobile Home Installation Freestanding Stove F2400M Listed Components For Mobile Home InstallationFlue Baffle Secondary AIR Tube Installation InstallationDoor Handle Brick InstallationSTEP-BY-STEP Optional Accessories Installation Glass InstallationBlower/Fan First Fire Operating InstructionsOperating Instructions Draft ControlASH Disposal Safety GuidelinesSafety Precautions FAN OperationMaintenance Parts List F2400M Stove Main AssemblyPart# Description S2400M Step Stove Main Assembly Parts ListPEDESTAL, Bottom Shield & LEG Options Firebrick Regency Freestanding Woodstove Warranty Lifetime WarrantyInstaller Please complete the following information

F2400M, S2400M specifications

Regency Wraps has long been known for its innovative solutions in food packaging, and the F2400M and S2400M models are prime examples of this commitment to quality and efficiency. Both models are designed to meet the needs of the modern kitchen, catering to both professional chefs and home cooks alike.

The F2400M model is particularly notable for its robust construction and user-friendly interface. It features a powerful motor capable of handling various wrap materials including plastic, foil, and parchment. This versatility allows users to easily transition between different types of wrapping, making it suitable for a broad range of food preparation tasks. Additionally, the F2400M incorporates an adjustable cutter that provides precise slicing, ensuring that users can create the perfect wrap every time.

On the other hand, the S2400M is designed with efficiency in mind. This model boasts a sleek design that saves counter space while maintaining a powerful performance. The S2400M is equipped with a built-in storage compartment for wrap rolls, allowing operators to keep everything organized and easily accessible. One of its standout features is the automatic cutter, which enhances safety and reduces the risk of injury during the wrapping process.

Both models utilize advanced technology to improve their functionality. The thermal sensors in the F2400M help regulate the temperature, ensuring that wraps are sealed securely without compromising food quality. Meanwhile, the S2400M’s intuitive touch controls simplify the wrapping process, making it easier for users to achieve consistent results.

In terms of characteristics, both models are designed for durability. The heavy-duty materials used in their construction ensure that they can withstand the rigors of daily use, making them ideal for busy kitchens. Furthermore, they are both energy-efficient, helping users to minimize their environmental impact while keeping their operations cost-effective.

In summary, the Regency Wraps F2400M and S2400M are exceptional tools for anyone looking to streamline their food wrapping processes. With advanced features, user-friendly designs, and robust construction, these models represent the pinnacle of modern food packaging technology. Whether you’re a professional chef or a home cook, investing in either of these models will elevate your food preparation and storage experience.