Emerson 2468CB, 2468CD 4.3MECHANICAL INSTALLATION, 4.3.2INSTALLING THE 24683D WALL MOUNTED UNIT

Models: 2468CD 2468CB

1 186
Download 186 pages 11.63 Kb
Page 124
Image 124

Remote Display Options 24683B, C & D

Hydrastep 2468CB & 2468CD Manual

4.3MECHANICAL INSTALLATION

Of the three types of remote display units, types 24683B and 24683C are intended for panel mounting and type 24683D is intended for wall mounting. The installation procedures for panel and wall mounting are described below.

4.3.1INSTALLING THE 24683B AND 24683C PANEL MOUNTED UNITS

The panel related dimensions for the 24683B and 24683C are:

Panel thickness:

24683B

= 2mm to 9mm

 

24683C

= 2mm to 20mm

Aperture:

24683B

= 139mm high × 67mm wide

 

24683C

= 186mm high × 92mm wide

The installation procedure is:

1.Ensure that the panel on which the remote display is to be fitted provides easy access to the electrical connections and is sited in a good viewing position.

2.Cut an aperture in the panel to the dimensions given above and remove any burrs.

3.Remove the clamps (if fitted) from the remote display unit and fit the unit into the aperture from the front of the panel.

4.Refit the clamps to the display unit and secure the unit to the panel.

The two clamps on the 24683B and 24683C each clip onto two metal studs on the case of the unit. Adjust the clamps from the rear of the unit with a suitable flat bladed screwdriver. Tighten the clamps until they press firmly against the panel to hold the unit in place.

4.3.2INSTALLING THE 24683D WALL MOUNTED UNIT

The 24683D Remote Display Unit is contained in an IP65 enclosure that can be fixed to the wall by four mounting brackets. Cables are routed to the internal PCB through glands in the base. The installation procedure is:

1.Place the unit against the surface to which it is to be fixed and mark the positions of the fixing points. These should be positioned on centres 190mm apart horizontally and 305mm apart vertically. Install suitable fixings and secure the unit to the wall.

2.Remove the four screws securing the clear cover of the unit and place the cover carefully to one side.

3.Remove the four screws securing the front panel of the unit and lay the panel, still attached by its ribbon cable, on top of the case.

4.Loosen the cable gland nuts, pass the cables through the glands, prepare the cable terminations, and fit the cable to the terminal block. (See Section 4.4.4 for details.)

5.Ensure that the cables are not strained within the unit, tighten the cable glands, and refit the front panel and clear cover.