Emerson 2468CB, 2468CD manual Category, Symptom, POSSIBLE CAUSES See Note, SOLUTION See Note

Models: 2468CD 2468CB

1 186
Download 186 pages 11.63 Kb
Page 2
Image 2
CATEGORY

CATEGORY

 

SYMPTOM

 

POSSIBLE CAUSES (See Note 1)

 

SOLUTION (See Note 2)

 

 

 

 

 

 

 

 

 

 

 

PSU (AC)

Hydrastep system does not power-up.

Wrong voltage setting.

 

Refer to Part 1, Section 2.4.2.4.

 

 

 

 

Incorrect supply.

 

 

 

 

 

 

Blown fuse.

 

 

 

 

 

 

Incorrect cable termination.

 

 

 

PSU (DC)

Hydrastep system does not power-up.

Incorrect supply.

 

Refer to Part 1, Section 2.4.2.4.

 

 

 

 

Blown fuse.

 

 

 

 

 

 

Incorrect cable termination.

 

 

 

 

 

 

 

 

 

 

 

MAIN DISPLAY

Chequered / intermittent display.

Incorrect configuration.

 

Refer to Part 1, Section 2.5.2.

 

 

No display.

 

 

 

Refer to Part 1, Section 2.5.2.1.

 

 

Yellow LED illuminated.

 

 

 

Refer to Part 1, Section 2.5.2.2.

 

 

 

 

 

 

 

 

 

REMOTE DISPLAY

Chequered / intermittent display.

Incorrect configuration.

 

Check Main Display, as above.

 

 

No display.

 

 

 

See Part 1, Section 4.2 (Relevant display).

 

 

Yellow LED illuminated.

Incorrect interface cable connection.

 

Check cable connections. See Part 1, Section4.4.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRODE ALARM

Flashing Red (steam) and Green (water)

Electrode contamination

Refer to Part 2, Section 3.

ERROR

 

LED’s with Yellow alarm LED illuminated.

 

 

 

 

 

 

 

 

Incorrect column installation reducing

Refer to Part 2, Section 2.3.

 

 

 

 

condensate flow.

 

 

 

 

 

 

Water conductivity is too high.

Refer to Part 1, Section 2.5.1.3.

 

 

 

Refer to Part 1, Section 2.5.1.4.

 

 

 

 

 

 

 

 

 

 

 

WATER/STEAM

Water above steam (green above red) with

Threshold not matched to application.

Refer to Part 1, Section 2.5.2.3.

SWITCHING

 

yellow LED illuminated

 

 

 

 

 

THRESHOLD

 

 

Electrode contamination.

Refer to Part 2, Section 3.

 

 

 

 

 

 

 

 

 

 

 

Note 1: Further detailed information can be found in Fault finding Part 1, Sections 2.6 and 4.5.

Note 2: References are to Operating Manuals 24685033 (for 2468CA and 2468CC models) and 24685034 (for 2468CB and 2468CD models).

Page 2
Image 2
Emerson 2468CB, 2468CD manual Category, Symptom, POSSIBLE CAUSES See Note, SOLUTION See Note