1.4HYDRASTEP 2468 UPGRADE PATHS AND AVAILABLE OPTIONS
Table 1.1 describes the available versions of the Hydrastep 2468 Electronic Gauging System and their possible options.
Existing System | Available Options | Comments | ||
|
| |||
| Description | Part No. |
| |
|
|
|
| |
| Relay output board | 24680504C | } | |
2468 CA or |
|
| } | |
2468 CC | Time delay relay | 24680509B | } Up to two boards (of any one | |
| output board |
| } type) can be fitted. | |
16 point EGS with |
|
| } | |
local display | 24680505A | } | ||
Single power | output board |
|
| |
| 24683B, C, or D | Up to 6 can be used | ||
supply. | Remote display | |||
| unit |
|
| |
| Input board | 24680501C | Provides an additional power | |
| upgrade (ac) |
| supply (ac mains source) and | |
|
|
| 16 point input circuit. Upgrades | |
|
|
| 2468CA to 2468CB. | |
| Input board | 24680516B | Provides an additional power | |
| upgrade (dc) |
| supply (24V dc source) and 16 | |
|
|
| point input circuit. Upgrades | |
|
|
| 2468CC to 2468CD. | |
| Relay output board | 24680504C | } | |
2468 CB or |
|
| } | |
2468 CD | Time delay relay | 24680509B | } Up to four boards (of any one | |
| output board |
| } type) can be fitted. | |
32 point EGS with |
|
| } | |
local display | 24680505A | } | ||
Dual power supply. | output board |
|
| |
Remote display | 24683B, C, or D | Up to 6 can be used | ||
| ||||
| unit |
|
| |
|
|
|
|
Note: If required, a 24680501C board can be fitted to a 2468CC (or a 24680516B board can be fitted to a 2468CA) to upgrade to a 2468CE. The 2468CE is a 32 point Electronic Gauging System (EGS) with one ac mains source power supply and one 24Vdc source power supply.
Table 1.1 - Upgrade paths and available options
24685034 |