Hydrastep 2468CB & 2468CD Manual

Remote Display Options 24683B, C & D

4.8SPECIFICATION

REMOTE DISPLAY UNITS

INDICATION

Red/green 6mm×3mm LEDs

CASE STYLE

24683B and 24683C: Panel mounting;

 

24683D: Rugged enclosure, to IP65/NEMA 4X

DIMENSIONS

24683B: 144mm×72mm×200mm deep (5.67”×2.83” ×7.87”)

 

24683C: 192mm×96mm×209mm deep (7.56”×3.7” ×8.23”)

 

24683D: 302mm×186mm×175mm deep (11.89”×7.32” ×6.89”)

PANEL CUT-OUT

24683B: 139mm×67mm

 

24683C: 186mm×92mm (7.32”×3.62”)

POWER SUPPLY

Derived from 2468 electronics unit or 20V - 54Vdc, 240mA

 

Absolute maximum limits at remote display terminals: 16V to 60Vdc

TERMINALS

Screw-clamp

CABLES

Note: The following cables fulfil the minimum requirements. Heavier cables may be used. Maximum gauge accepted by connectors is 16AWG (1. 5mm2).

Powered from 2468 electronics

1.5mm2, 7×0.53mm individually shielded, 5-pair. Overall

(up to 1000m from 2468 unit)

shield. Galvanised steel wire armour. One cable

BASEEFA conformity*

required. (Mobrey Part No.480121230)

Unit locally powered

22

AWG (0.324mm2, 7×0.25mm) individually shielded, 2-pair

(up to 1000m from main unit)

twisted (Belden type No. 8723). Two cables required.

 

22

AWG (0.324mm2, 7×0.25mm) individually shielded, 3-pair

 

twisted (Belden type No. 8777). One cable required.

 

 

 

Powered from 2468 electronics

22

AWG (0.324mm2, 7×0.25mm) individually shielded, 2-pair

(up to 250m from 2468 unit)

twisted (Belden type No. 8723). Two cables required.

 

22

AWG (0.324mm2, 7×0.25mm) individually shielded, 4-pair

 

twisted (Alpha Wire type No. 6054C). One cable required.

 

 

 

Powered from 2468 electronics

22

AWG (0.324mm2, 7×0.25mm) individually shielded, 3-pair

(up to 500m from 2468 unit)

twisted (Belden type No. 8777). Two cables required.

 

22

AWG (0.324mm2, 7×0.25mm) individually shielded, 6-pair

 

twisted (Belden type No. 8778). One cable required.

 

 

 

Powered from 2468 electronics

18

AWG (0.826mm2, 16×0.25mm) individually shielded, 3-pair

(up to 1000m from 2468 unit)

twisted (Belden type No. 9773). Two cables required.

 

22

AWG (0.826mm2, 16×0.25mm) individually shielded, 6-pair

 

twisted (Belden type No. 9774). One cable required.

 

 

 

*The main Hydrastep 2468 unit is approved for operation in a hazardous environment to EExnA T4. Compliance with this approval requires that armoured cable is used to connect a remote display to the main unit. A remote display must not be used in a hazardous environment.

24685034

4-17

Page 135