Hydrastep 2468CB and 2468CD Manual

2468CB & 2468CD Dual Power Supply Version

2.3.3.2Links LK2, LK3, LK4 and LK5

These links are used to select either the 8 - 16 display mode (two LEDs per electrode) or the 18 - 32 display mode (one LED per electrode).

Two link headers are provided with the unit and must be fitted in either LK2 and LK4, to enable the 8 - 16 electrode mode, or LK3 and LK5, to enable the 18 - 32 electrode mode.

 

No. of Electrodes used

Link Headers fitted

 

 

 

 

8 - 16 electrodes

LK 2 & LK 4

 

 

 

 

18 - 32 electrodes

LK 3 & LK 5

 

 

 

See also Figure 2.5 on page 2-21.

 

2.3.4PCB INTERCONNECTIONS

Signal interconnection between the input boards and the display board is via ribbon cables. The power supplies to the display board come from each input board via a 6-core cable.

Slots are provided in the base plate to guide the cables towards the hinge-side of the enclosure case, thus minimising any cable strain when the enclosure lid is opened. See Figure 2.1 for layout details.

24685034

2-7

Page 27
Image 27