12 MAINTENANCE

Troubleshooting

If your transceiver seems to be malfunctioning, please check the following points before sending it to a service center.

PROBLEM

POSSIBLE CAUSE

SOLUTION

REF.

Does not turn on.

• Power connector has a poor contact.

• Check the connector pins.

 

• Polarity of the power connection is reversed.

Re-connect the power cable observing the proper

pgs. V,

 

 

polarity. Replace the fuse if damaged.

76

 

• Blown fuse.

• Check the cause, then replace the fuse.

p. 76

 

 

 

 

No sound comes from the

• Volume is too low.

• Rotate [VOL] clockwise.

p. 15

speaker.

• The audio mute function is activated.

• Push any switch or key to deactivate it.

p. 21

 

• Squelch is set too high.

• Set the squelch level to the threshold.

p. 15

 

• A selective call or squelch function is activated

• Turn the appropriate function OFF.

pgs.

 

such as pocket beep or tone squelch.

 

52–54

 

 

 

 

Sensitivity is low and only

• Antenna feedline or the antenna connector has a

• Check, and if necessary, replace the feedline or sol-

p. VI

strong signals are audible.

poor contact or is short circuited.

der the antenna connector again.

 

 

• Squelch attenuator function is activated.

• Set [SQL] between 10–12 o’clock position.

p. 16

 

 

 

 

No contact possible with

• The other station is using tone squelch.

• Turn the tone squelch function ON.

p. 54

another station.

• The transceiver is set to duplex.

• Set to simplex.

p. 23

 

 

 

 

Repeater cannot be ac-

• Wrong offset frequency is programmed.

• Correct the offset frequency.

p. 24

cessed.

• Wrong subaudible tone frequency is programmed.

• Correct the subaudible tone frequency.

p. 22

 

 

 

 

Frequency cannot be set.

• The frequency lock function is activated.

• Turn the function OFF.

p. 14

 

• Priority watch is paused on the watching frequency.

Push [M/CALL•PRIO] for 1 sec. to cancel the watch.

p. 47

 

 

 

 

Frequency cannot be set

• The frequency lock function is activated.

• Turn the function OFF

p. 14

via the microphone.

• The microphone keypad lock function is activated.

• Push [FUNC] then [SQLZ #(16KEY-L)] to deactivate

p. 14

 

• Priority watch is paused on the watching fre-

the microphone keypad lock function.

 

 

quency.

Push [M/CALL•PRIO] for 1 sec. to cancel the watch.

p. 47

 

 

 

 