Regency U38-LP, U38-NG Front Door Installation, Louver Installation, Test for Flue Spillage

Page 12
Diagram 1

INSTALLATION

FRONT DOOR

INSTALLATION

(packaged separately)

1)Open the two side panels.

2)Slide the door onto the two hinge pins making sure the two pieces are flush to- gether. See di- agram 1.

3)Close the door.

The latch plate must be centered around the alignment pin. See dia- gram 2. If the latch plate interferes with the cor-

ner of the stove you may want to angle the

plate slightly so the door closes easier.

4)The latches should already be at the proper setting. If they are too hard or too easy to close, you may want to adjust them by loosening the latch catch. See diagram 3.

LOUVER

INSTALLATION

1)Attach the top & bottom louvers to the side stove panel using 2 screws per side.

Note: If the flue is blocked or has a strong reverse flow, the thermally actuated safe- ty switch mounted in the draft hood will automatically shut off the gas supply within about 10 minutes. If the heater turns off because of this during the spill- age test, check for the cause of the lack of draft.

TEST FOR FLUE

SPILLAGE

A "spillage" test must be made before the installed unit is left with the customer. Follow the procedure below:

1)Start all exhaust fans in the home and any other gas appliances. Then close all doors and windows.

The thermally activated safety switch must be manually reset before first star- tup.

Diagram 2

5)Remove the blue plastic protective coating from the glass.

6)Test the seal around the door by placing a piece of paper between the unit and the door, close the door and try to pull the paper out. If it slips out easily, then the door is not properly sealed. Tighten or loosen the latch. See diagram 3.

Diagram 3

2)Light the unit and set controls to maximum.

3)After five minutes, test that there is a "pull" on the flue by placing a smoke match, cigarette or similar device which gives off smoke, on the edge of the draft hood. See diagrams.

OPTIONAL WALL

THERMOSTAT

A wall thermostat may be installed if desired. Connect the wires as per the wiring diagrams. Note that the wires are connected to the "TH" on the gas valve. Use table below to determine the maximum wire length:

Note: Preferable if the thermostat is in- stalled on an interior wall.

Regency offers an optional programmable ther- mostat but any 250-750 millivolt rated non- anticipator type thermostat that is CSA, ULC or UL approved may be used.

Note: The door latch may require ad-

CAUTION

Do not connect the millivolt

justment as the door gasket mate-

The smoke should be drawn into the draft hood.

wall thermostat wires

rial compresses after a few fires and after glass replacement. Turn the latch catch inward or outward to loosen or tighten.

12

If the smoke is not drawn into the draft hood,to the 120V wires. turn the unit off and check for the cause of lack

of draft.

.

Regency U38 ULTIMATE Freestanding Gas Stove

Image 12
Contents Ultimate U38 Freestanding Gas Stove To the New Owner U38-NG & U38-LPRegency U38 Ultimate Freestanding Gas Stove Table of Contents Safety Label Copy of the Safety Label for the U38 Freestanding Gas StoveInstallation General Safety InformationInstallation Checklist Before YOU StartU38-NG & U38-LP Reference Dimensions Optional Outside AIRClearances to Combustibles Draft Hood High ElevationGAS Pipe Pressure Testing GAS ConnectionHigh Elevation U38-NG Pilot assembly is now accessible for Steps 4 to Conversion from Natual GAS to PropaneBurner Orifice LOG SET Installation Conversion to Lower BTU Rating for U38Natural Gas Conversion Kit 730-920 Contains Propane Conversion Kit 730-922 ContainsPins on Rear Log Support PinCutoutNotch Lava rockFront Door Installation Louver InstallationTest for Flue Spillage Optional Wall ThermostatOptional Remote Control WiringThermostat Wire Table Final CheckOperating Instructions Copy of the Lighting Plate Instructions Pilot Adjustment Aeration AdjustmentNormal Operating Sounds GAS Appliances Maintenance FAN Maintenance Installing GlassPanel Door Removing Valve Magnetic type screwdriverParts List U38 Main AssemblyDescription U38 Burner & LOG Assembly U38 Door Assemblies Warranty ConditionsInstaller Please complete the following information

U38-NG, U38-LP specifications

The Regency U38-LP and U38-NG are innovative gas fireplaces designed to deliver both warmth and elegance to any living space. These units exemplify modern craftsmanship while ensuring high efficiency, making them popular choices among homeowners looking to enhance their indoor ambiance.

One of the key features of the Regency U38 series is its versatile design. Both models can be easily installed in a variety of settings, including new constructions and retrofits. Their clean, contemporary lines and large viewing area provide a stunning focal point for any room, allowing for maximum enjoyment of the flames. The U38-LP operates on liquid propane, while the U38-NG uses natural gas, catering to different fuel preferences and availability.

Efficiency is a hallmark of the Regency U38 series. With an impressive thermal efficiency rating, both models ensure minimal heat loss while maximizing warmth output. This efficiency not only translates into cost savings on energy bills but also contributes to a more environmentally friendly home. The switchable electronic ignition system enhances their user-friendliness, providing instant warmth with the push of a button.

The construction of the U38 fireplaces is another standout feature. They are built using high-quality materials, including a robust steel body and premium glass, ensuring durability and performance over time. Among the optional features available are customizable media options, such as glass crystals or decorative logs, allowing homeowners to personalize their fireplace to suit their tastes.

Advanced technology sets the Regency U38 series apart from traditional fireplaces. The units come equipped with an integrated, thermostatic remote control that allows users to adjust the temperature effortlessly. Additionally, the advanced airflow system ensures even heat distribution throughout the room, while the fan assist option can further enhance heat circulation.

Safety features are paramount in the design of the U38 fireplaces. They include a built-in safety shutdown system that activates if any anomalies are detected, providing peace of mind for users.

In summary, the Regency U38-LP and U38-NG fireplaces offer an ideal combination of style, efficiency, and advanced technology. Their attractive design, customizable options, energy-saving performance, and comprehensive safety features make them an excellent choice for modern homes looking for effective heating solutions without compromising on aesthetics.