Regency U38-NG, U38-LP installation manual Maintenance

Page 17

MAINTENANCE

MAINTENANCE

INSTRUCTIONS

1)

Always shut the valve off before cleaning.

 

For relighting, refer to lighting instructions.

 

Keep the burner and control compartment

 

clean by brushing and vacuuming at least

 

once a year. When cleaning the logs, use

 

a soft clean brush as the logs are fragile

 

and easily damaged.

2)

Clean glass (never when unit is hot), ap-

 

pliance, louvers, and door with a damp

 

cloth. Never use an abrasive cleaner. The

 

gold louvers (and optional gold door) may

 

be scratched if abrasives are used to

 

clean them.

 

The heater is finished in a heat resistant

 

paint and should only be refinished with

CLOTHING OR OTHER FLAMMA- BLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLI- ANCE.

DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE APPLIANCE AND TO REPLACE ANY PART OF CON- TROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UN- DER WATER.

6)Verify proper operation after servicing.

GLASS

REPLACEMENT

Your Regency stove is supplied with high temperature, 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce. In the event that you break your glass, purchase your replacement from an authorized Regency dealer only, and follow the step-by-step instructions for replacement.

Never operate your unit with broken glass.

WARNING: Do not operate appliance with the glass front removed, cracked or bro- ken. Replacement of the glass should be done by a licensed or qualified service person.

heat resistant paint (not with wall paint).

Regency uses StoveBright Paint - Metallic

Black #6309.

3) Make a periodic check of burner for proper

position and condition. Visually check the

flame of the burner periodically, making

sure the flames are steady; not lifting or

floating. If there is a problem, call a qualified

service person.

4) The appliance and venting system must be

inspected before use, and at least annual-

ly, by a qualified field service person, to

ensure that the flow of combustion and

ventilation air is not obstructed.

During the annual service call, the burners

should be removed from the burner tray

and cleaned. Replace the embers - do not

block the pilot or burner ports.

5) Keep the area near the appliance clear and

free from combustible materials, gasoline

and other flammable

vapours and liquids.

WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURE AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CAREFUL- LY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE AP- PLIANCE.

CAUTION: ANY SAFETY SCREEN OR GUARD REMOVED FOR SERV- ICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERAT- ING THE APPLIANCE.

LOG REPLACEMENT

The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs. The pilot light generates enough heat to burn someone. If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagram under Log Installation.

Note: Improper positioning of logs may create carbon build-up and will alter the unit’s performance which is not covered under war- ranty.

DOOR AND GLASS

GASKET

If the door gasket requires replacement use 7/8" diameter oval door gasket (Part # 650- 920). The glass requires 5/8" flat glass gasket. See your Regency dealer.

GOLD-PLATED DOORS

The 24 carat gold plated finish on the door requires little maintenance, and need only be cleaned with a damp cloth. DO NOT use abrasive materials or chemical cleaners, as they may harm the finish and will void the warranty. Clean any fingerprints off before turning the unit on.

MITRED DOOR

Removing Glass:

Note: Wearing gloves will protect your hands while handling glass.

1)Remove the door from the unit and place on a soft surface to prevent scratching.

2)Pull out the door gasket.

3)Remove the 24 nuts holding the glass re- tainers in place. Do not remove the nuts underneath the retainers.

4)Remove the door catch plate.

5)Remove glass retainers on sides first (3 each side) then remove two center retain- ers.

Note: Center glass retainers are glued to center glass.

6)Remove glass from extrusions. When re- moving center glass, leave white insulation in place.

Regency U38 ULTIMATE Freestanding Gas Heater

17

Image 17
Contents Ultimate U38 Freestanding Gas Stove Regency U38 Ultimate Freestanding Gas Stove To the New OwnerU38-NG & U38-LP Table of Contents Copy of the Safety Label for the U38 Freestanding Gas Stove Safety LabelGeneral Safety Information InstallationInstallation Checklist Before YOU StartClearances to Combustibles U38-NG & U38-LP Reference DimensionsOptional Outside AIR High Elevation Draft HoodHigh Elevation U38-NG GAS Pipe Pressure TestingGAS Connection Burner Orifice Pilot assembly is now accessible for Steps 4 toConversion from Natual GAS to Propane Conversion to Lower BTU Rating for U38 LOG SET InstallationNatural Gas Conversion Kit 730-920 Contains Propane Conversion Kit 730-922 ContainsPinCutout Pins on Rear Log SupportNotch Lava rockLouver Installation Front Door InstallationTest for Flue Spillage Optional Wall ThermostatWiring Optional Remote ControlThermostat Wire Table Final CheckOperating Instructions Copy of the Lighting Plate Instructions Normal Operating Sounds GAS Appliances Pilot AdjustmentAeration Adjustment Maintenance Panel Door FAN MaintenanceInstalling Glass Magnetic type screwdriver Removing ValveDescription Parts ListU38 Main Assembly U38 Burner & LOG Assembly U38 Door Assemblies Conditions WarrantyInstaller Please complete the following information

U38-NG, U38-LP specifications

The Regency U38-LP and U38-NG are innovative gas fireplaces designed to deliver both warmth and elegance to any living space. These units exemplify modern craftsmanship while ensuring high efficiency, making them popular choices among homeowners looking to enhance their indoor ambiance.

One of the key features of the Regency U38 series is its versatile design. Both models can be easily installed in a variety of settings, including new constructions and retrofits. Their clean, contemporary lines and large viewing area provide a stunning focal point for any room, allowing for maximum enjoyment of the flames. The U38-LP operates on liquid propane, while the U38-NG uses natural gas, catering to different fuel preferences and availability.

Efficiency is a hallmark of the Regency U38 series. With an impressive thermal efficiency rating, both models ensure minimal heat loss while maximizing warmth output. This efficiency not only translates into cost savings on energy bills but also contributes to a more environmentally friendly home. The switchable electronic ignition system enhances their user-friendliness, providing instant warmth with the push of a button.

The construction of the U38 fireplaces is another standout feature. They are built using high-quality materials, including a robust steel body and premium glass, ensuring durability and performance over time. Among the optional features available are customizable media options, such as glass crystals or decorative logs, allowing homeowners to personalize their fireplace to suit their tastes.

Advanced technology sets the Regency U38 series apart from traditional fireplaces. The units come equipped with an integrated, thermostatic remote control that allows users to adjust the temperature effortlessly. Additionally, the advanced airflow system ensures even heat distribution throughout the room, while the fan assist option can further enhance heat circulation.

Safety features are paramount in the design of the U38 fireplaces. They include a built-in safety shutdown system that activates if any anomalies are detected, providing peace of mind for users.

In summary, the Regency U38-LP and U38-NG fireplaces offer an ideal combination of style, efficiency, and advanced technology. Their attractive design, customizable options, energy-saving performance, and comprehensive safety features make them an excellent choice for modern homes looking for effective heating solutions without compromising on aesthetics.