MAINTENANCE

If your fan requires maintenance or replace- ment, access to the fan is through the access panel on the rear wall of the firebox. NOTE: the unit MUST NOT be operated without the fan access panel securely in place and correctly sealed.

IMPORTANT

Disconnect power supply

before servicing

WARNING: Electrical Grounding Instructions

This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.

FAN MAINTENANCE

To remove fan:

1)Unplug or disconnect power source to stove.

2)Remove all logs and the rear log support, then remove the 6 screws holding the access panel in place.

3)Disconnect white wire from fan to power cord.

4)Disconnect black wire from molex plug to thermodisc.

5)Unplug wire harness on left rear side panel (from inside the stove).

6)Disconnect green ground wire from fan body.

7)Lift fan off of the 2 pins, tip forward and pull through firebox opening.

IMPORTANT: These fans do collect a lot of dust from within your home. Ensure you maintain these fan mo- tors on a regular basis by vacuuming out the fan squirrel cages.

Replacing fan:

Reverse above steps. Hint for pushing fan down onto pins - rub a bit of dish soap on the grommet so it will slide more easily onto the pin. Check to make sure the fan is seated properly on the pins

-try to move the fan back and forth, there should be no noise, if there is check that the grommets haven't come loose.

Caution: Ensure that the wires do not touch a hot surface.

CAUTION:

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.

18

Regency U41-3 ULTIMATE Gas Fireplace Insert

Page 18
Image 18
Regency U41-NG3, U41-LP3 installation manual FAN Maintenance, To remove fan, Replacing fan