Regency U41-LP3 Log Replacement, Gold-Plateddoors, Door Gasket And Glass Gasket, Latch Adjustment

Models: U41-LP3 U41-NG3

1 24
Download 24 pages 36.81 Kb
Page 17
Image 17
LOG REPLACEMENT

MAINTENANCE

LOG REPLACEMENT

The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs. The pilot light generates enough heat to burn someone. If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagram under Log Installation.

NOTE: Improper positioning of logs may create carbon build-up and will alter the unit’s performance which is not covered under warranty.

MITRED DOOR

Removing Glass

Note: Wearing gloves will protect your hands while handling glass.

1)Remove the door from the unit and place on a soft surface to prevent scratching.

2)Pull out the door gasket.

3)Remove the 24 nuts holding the glass retain- ers in place. Do not remove the nuts under- neath the retainers.

4)Remove the door catch plate.

a. tighten top & bottom outside corner nuts (2)

b.tighten inside nuts (3)

c.tighten top & bottom inside

corners (2)

8)Tighten the 10 nuts on center glass retain- er.

9)Repeat step 7 for other side panel.

10)Replace new gasket by gluing it in place.

11)Install door onto stove and check the seal.

GOLD-PLATED DOORS

The 24 carat gold plated finish on the door requires little maintenance, and need only be cleaned with a damp cloth. DO NOT use abrasive materials or chemical cleaners, as they may harm the finish and void the warranty. Clean any fingerprints off before turning the unit on. If gasket seal is not tight - door may discolour.

DOOR GASKET AND

GLASS GASKET

If the door gasket requires replacement use 7/ 8" diameter oval door gasket (Part # 650-920). The glass requires 5/8" flat glass gasket (Part

# 936-243). See your Regency Dealer.

LATCH ADJUSTMENT

The door latch may require adjustment as the door gasket material compresses after a few fires and after glass

replacement. Turn the adjustable latch to tight- en or loosen the latch.

GLASS

REPLACEMENT

Your Regency stove is supplied with high temperature, 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce. In the event that you break your glass by impact, purchase your replace- ment from an authorized Regency dealer only, and follow our step-by-step instructions for replacement.

5)Remove glass retainers on sides first (3 each side) then remove two center retain- ers.

Note: Center glass retainers are glued to center glass.

6)Remove glass from extrusions. When re- moving center glass, leave white insulation in place.

Installing Glass

1)Install both center and side glass onto extrusions as per diagram.

2)Place glass assembly into door frame.

3)Install retainers by placing 1 drop of glue where previously glued and put in place.

4)Install side retainers.

5)Install door catch plate.

6)Install the 24 nuts loosely, do not tighten yet.

7)Tighten side panels nuts using the following procedure:

PANELDOOR

1)Remove the door from the unit and place on a soft surface to prevent scratching.

2)Pull out the door gasket.

3)Remove the nuts holding the glass retain- ers in place.

4)Remove the glass retainers (sides, top and bottom) and the door catch plate.

5)Replace the glass. The glass must have gasketing around it.

6)Reverse the previous steps, replace the retainers and fasten with the nuts but do not overtighten, as this can break the glass. Note: the door catch plate fits on top of the left side retainer.

7)Put gasket glue on the retainers, but do not put glue on the screws. Replace the door gasket, the two ends butt tight together on the bottom edge of the door.

8)Replace door on the stove and check the seal.