Regency U41-NG3 Operating Instructions, First Fire, Lighting Procedure, Shutdown Procedure

Models: U41-LP3 U41-NG3

1 24
Download 24 pages 36.81 Kb
Page 14
Image 14
OPERATING

OPERATING INSTRUCTIONS

OPERATING

INSTRUCTIONS

Before operating this appliance, proceed through the following check list.

1)Read and understand these Instructions before operating this appliance.

2)Check to see that all wiring is correct and enclosed to prevent possible shock.

3)Check to ensure there are no gas leaks.

4)Make sure the three door glass pieces are in place. Never operate the appliance with any of the door glass removed or with the door open. Do not strike the glass or slam the door shut.

Warning: Do not operate appliance with glass front removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person.

5)

Verify that all venting and the cap is unob-

 

structed.

6)

Verify log placement. If the pilot cannot be

 

seen when lighting the unit - the logs or the

5)Wait five minutes to allow gas, that may have accumulated in the main burner com- partment, to escape. If you do smell gas, follow the instructions on the front of this manual. If you don't smell gas continue on to the next step.

6)Turn the gas control counterclockwise to "PILOT".

7)Push in control knob all the way and hold in. Immediately push black button on spark igniter until pilot lights. Continue to hold the control knob in for approximately one minute, then release the gas control knob. The pilot flame should continue to burn. If the pilot does not remain lit, repeat opera- tion allowing a longer period before re- leasing gas control knob.

8)Turn gas control knob counterclockwise to "ON".

9)Use rocker switch to operate main burner.

10)Rotate the variable flame control to adjust the flame height higher or lower.

11)Close the bottom louver assembly and tighten the wingnut.

12)The door must be closed when operating the unit.

FIRST FIRE

The first fire in your stove is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your fireplace for at least four (4) hours the first time you use it with the fan on. When first operated, the unit will release an odour caused by the curing of the paint, the burning off of any oils remaining from manufacturing. Smoke detectors in the house may go off at this time. Open a few windows to ventilate the room for a couple of hours.

The glass panel may require cleaning after the unit has cooled down. DO

NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT.

Note: When the glass is cold and the appliance is lit, it may cause con- densation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up.

DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE.

 

embers have been incorrectly positioned.

7)

The unit should never to turned off and on

 

without a minimum of a 60 second wait.

8)

When lighting the appliance, the inside of

 

the glass may fog up. This will burn off after

 

a few minutes of operation.

DO NOT BURN THE APPLIANCE WITH THE DOOROPEN.

LIGHTING

PROCEDURE

IMPORTANT: Gas cock knob cannot be turned from "PILOT" to "OFF" unless it is partially depressed.

1)Open the left side door when lighting the pilot, but once the pilot is lit, DO NOT operate the unit with the front glass door open.

2)Open the bottom louver assembly by turn- ing the wing nut and swinging the louvers out. (See page 8 for diagram.)

3)If the control knob is in the "OFF" position proceed to Step 5.

4)Push in gas control knob slightly and turn clockwise to "OFF".

Knob cannot be turned from "PILOT" to "OFF" unless knob is pushed in slightly.

Do not force.

SHUTDOWN

PROCEDURE

1)Use the rocker switch to turn off the main burner.

2)Open the bottom louver assembly by turn- ing the wing nut and swinging the louvers out.

3)Push in the gas control knob slightly and turn clockwise to "OFF". Do not force.

4)Disconnect all electric power to the appli- ance if service is to be performed.

AUTOMATIC

CONVECTION FAN

OPERATION

The fan operates automatically, turn the knob on the side of the faceplate to adjust to the desired speed. The fan will turn on as the stove comes up to operating temperature. After the unit has been turned off and the unit cooled to below a useful heat output range the fan will shut off automatically.

14

Regency U41-3 ULTIMATE Gas Fireplace Insert

Page 14
Image 14
Regency U41-NG3, U41-LP3 Operating Instructions, First Fire, Lighting Procedure, Shutdown Procedure, Do not force