MAINTENANCE

MAINTENANCE

INSTRUCTIONS

1)Always turn off the valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs, use a soft clean paint brush as the logs are fragile and easily damaged.

2)Clean glass (never when unit is hot), appli- ance, louvres, and door with a damp cloth. Never use an abrasive cleaner. The gold louvres (and optional gold door) may be scratched if abrasives are used to clean them.

The heater is fi nished in a heat resistant paint and should only be refi nished with heat resistant paint (not with wall paint). Regency® uses StoveBright Paint - Metallic Black #6309.

3)Make a periodic check of burner for proper position and condition. Visually check the flame of the burner periodically, making sure the flames are steady; not lifting or floating. If there is a problem, call an authorized service person.

4)The appliance and fl ueing system must be inspected before use, and at least annu- ally, by an authorized fi eld service person, to ensure that the fl ow of combustion and ventilation air is not obstructed.

During the annual service call, the burners should be removed from the burner tray and cleaned. Replace the embers but do not block the pilot.

5)Keep the area near the appliance clear and free from combustible materials, gasoline, and other fl ammable vapours and liquids.

WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURE AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CAREFULLYSUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. IMMEDIATELY CALL AN AUTHORIZED SERVICE TECHNI- CIAN TO INSPECT THE APPLI- ANCE AND TO REPLACE ANY

PART OF CONTROLSYSTEMAND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER.

CAUTION: ANY SAFETY SCREEN OR GUARD REMOVED FOR SERV- ICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERAT- ING THE APPLIANCE.

CLOTHING OR OTHER FLAM- MABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.

6)Each time the appliance is lit, it may cause condensation and fog the glass. This condensation and fog is normal and will disappear in a few minutes as the glass heats up.

Never operate the appliance without the glass properly secured in place or with the door open.

7)Periodically check the pilot fl ames. Correct fl ame pattern has three strong blue fl ames: 1 fl owing around the thermopile and 1 around the thermocouple, and 1 fl owing across the rear of the burner (it does not have to be touching the burner).

Note: If you have an incorrect flame pat- tern, contact your Regency® dealer for further instructions.

Top View of pilot fl ame

Incorrect fl ame pattern will have small, probably yellow fl ames, not coming into proper contact with the rear of the burner or thermopile.

Top View of pilot fl ame

GENERAL

FLUE MAINTENANCE

Conduct an inspection of the fl ueing system semi-annually. Recommended areas to inspect as follows:

1)Check the Flueing System for corrosion in areas that are exposed to the elements. These will appear as rust spots or streaks, and in extreme cases, holes. These com- ponents should be replaced immediately.

2)Checkforevidencesofexcessivecondensa- tion, such as water droplets forming in the innerliner,andsubsequentlydrippingoutthe joints, Continuous condensation can cause corrosion of caps, pipe, and fi ttings. It may be caused by having exterior portions of the system being exposed to cold weather.

3)Inspect joints, to verify that no pipe sec- tions or fi ttings have been disturbed, and consequently loosened.

LOG REPLACEMENT

The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs. The pilot light generates enough heat to burn someone. If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagram under Log Installation.

Note: Improper positioning of logs may create carbon build-up and will alter the unit’s performance which is not covered under warranty.

GOLD-PLATED DOORS

The 24 carat gold plated fi nish on the door requires little maintenance, and need only be cleanedwithadampcloth. DONOTuseabrasive materials or chemical cleaners, as they may harm the finish and void the warranty. Clean any

ngerprints off before turning the unit on. If the door starts to discolour, check the gasket seal and replace if necessary.

DOOR GASKET

If the door gasket requires replacement use 7/8" diameter oval door gasket (Part # 650- 920).

20

F37 Regency® Rear Flued Room Sealed Freestanding Gas Heater

Image 20
Contents Manual Please Keep These Instructions For Future ReferenceTo the New Owner Table of Contents Data Badge Installation SpecificationsGeneral Safety Information Before YOU StartClearances to Combustibles Installation ChecklistLocating Your Regency GAS Stove Exterior Flue Termination Locations Clearance k in mmFlueing Installation Precautions Safety Precautions For the InstallerPlanning Your Flueing Installation FlueingVertical Terminations Using Dura-Vent Flueing System Flueing Arrangements Vertical TerminationsStraight Vertical Terminations Offset to Vertical TerminationsSnorkel Terminations Horizontal InstallationsOptional Components Below Grade Snorkel Installation Hint Apply sealant to female endVertical Termination with CO-LINEAR Flex System GAS ConnectionConversion Kit Contains Qty Description NG 10mm open LPG 10mm open Aeration AdjustmentLOG SET Installation Door Installation Packaged Separately Testing Louvre InstallationGAS Pipe Pressure Optional Wall ThermostatOptional Remote Control WiringThermostat Wire Table Final CheckOperating Instructions For Your Safety Read Before Lighting Copy of the Lighting Plate InstructionsMaintenance Latch Adjustment Glass ReplacementInstalling Glass Never operate your unit with broken glassFAN Maintenance Removing ValveTo remove fan Replacing FanMaintenance Parts List Main AssemblyBurner & LOG Assembly Door Assemblies Warranty ConditionsExclusions General

F37-LPG, F37-NG specifications

The Regency F37-LPG and F37-NG are contemporary gas fireplaces that represent a perfect blend of modern design and efficiency, catering to both propane (LPG) and natural gas (NG) needs. These models are engineered to enhance living spaces while providing optimal warmth and comfort. Their elegant appearance and advanced technologies make them a popular choice for homeowners seeking an aesthetically pleasing and functional heating solution.

One of the key features of the Regency F37 series is its large viewing area, which allows for an unobstructed view of the flames, creating a visually stunning focal point in any room. The fireplace's design includes a clean front and minimalistic aesthetics that can complement various interior styles, from traditional to contemporary. The F37 offers an array of customizable options, including various finishes, decorative media, and fireplace configurations.

Technologically, the Regency F37 is equipped with an advanced burner system that enhances the flame presentation while maintaining high efficiency. The system produces realistic flames and glowing embers, emulating the look of a traditional wood-burning fire without the hassle of real wood. Additionally, the fireplaces feature a precise control system, allowing users to adjust the flame height and heat output according to their preferences.

In terms of efficiency, the F37 series boasts impressive energy ratings, ensuring that homeowners can enjoy warmth without incurring excessive costs. The fireplaces are designed with an emphasis on heat retention, utilizing modern insulation and venting technologies that promote optimal performance. With a focus on environmental sustainability, Regency ensures that their units produce lower emissions, making the F37 series an eco-friendly choice for heating.

The ease of installation is another significant advantage of the Regency F37, with flexible venting options designed to accommodate various home layouts. Whether it is an existing space or a new construction, the fireplace can be adapted to meet specific design and functionality needs.

In summary, the Regency F37-LPG and F37-NG are exceptional gas fireplaces that combine striking design with cutting-edge technology. Their large viewing areas, customizable options, high efficiency, and eco-friendly features make them an excellent addition to any home, ensuring comfort and style for years to come.