Regency U37-LP1, U37-NG1 installation manual FAN Maintenance, Removing Valve, Replacing Fan

Page 30

MAINTENANCE

FAN MAINTENANCE

4) Lift fan off of the 2 pins, tip back and pull

 

 

through the opening. Disconnect the green

If your fan requires maintenance or replacement,

ground wire from the right side of the fan as

soon as you can reach it.

access to the fan is through the plate on the rear

 

 

 

 

 

wall of the fi rebox. NOTE: the unit MUST NOT

 

 

 

 

 

be operated without the fan access panel

 

 

 

 

 

securely in place and correctly sealed.

 

 

 

 

 

 

 

 

 

 

IMPORTANT: These fans collect a lot of dust from within your home. Ensure you maintain these fan motors on a regular basis by vacuuming out the fan squirrel cages,aroundthemotor,andaroundthe grills on the back of the stove.

REMOVING VALVE

If your valve requires maintenance or replace- ment, use the following instructions:

Note: Alwayscloseoffthegassupplybefore removing the valve.

1)Open front pedestal door. You may want to put a soft cloth on the base of the unit so that when the pedestal door is open it doesn't scratch the paint. See diagram below.

IMPORTANT

Disconnect power supply

before servicing

WARNING:

Electrical Grounding Instructions This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut orremovethegroundingprongfrom this plug.

To Remove Fan:

1)Unplug or disconnect power source to stove.

2)Remove the rear

access panel on the back of the stove. The fan can only be accessed from the back of the stove.

3)Unclip the black and white wires from the fan mo- tor.

Replacing Fan:

Reverse the above steps (1 - 4). Make sure the fan wires and the ground wire are reattached.

Hint for pushing fan down onto pins - rub a bit of dish soap on the grommet so it will slide more easily onto the pin. Check to make sure the fan is seated properly on the pins - try to move the fan back and forth, there should be no noise, if there is check that the grommets haven't come loose.

2) Undo the six screws holding the control panel

in place.

3) Disconnect all wires from the back of the con- trolpanelandthenremovepanel. Youshould lay the panel on a soft cloth so it doesn't get marked up. See diagram above.

30

U37-1 Regency® ULTIMATE Rear Vent Direct Vent Freestanding Gas Stove

Image 30
Contents Ultimate U37 Rear Vent Information for MOBILE/MANUFACTURED Homes After First Sale To the New OwnerTable of Contents Safety Label Copy of Safety Label for U37Requirements MA Code CO DetectorGeneral Safety Information InstallationSpecifications Important Message Save These InstructionsClearances to Combustibles Installation ChecklistManufactured Mobile Home Additional Requirements Locating Your GAS StoveExterior Vent Terminal Locations Venting Installation Precautions Safety Precautions For the InstallerPlanning Your Venting Installation Rigid Pipe Venting Components List SV4LB6Offset to Vertical Terminations Using Rigid Piping SystemsStraight Vertical Terminations Vent Restrictor PositionAlternate Snorkel Termination Cap Horizontal TerminationsOptional Components Snorkel TerminationsBelow Grade Snorkel Installation Hint Apply sealant to female endVertical Termination with CO-LINEAR Flex System Required Parts DescriptionAlternate Approved Caps Approved for US Installations Only GeneralConverting a Factory Built Metal Chimney Converting Masonry Chimney Conversion KIT# 514-969 from NG to LP Conversion Kit Contains QtyInstallation of the DC Sparker Green ground wire GAS Connection Aeration AdjustmentLOG SET Installation High ElevationA02-65 Thermocouple Connection GAS Pipe Pressure TestingValve Description Ports on the valveWall Thermostat Louver InstallationOptional Remote Control Final CheckWiring Diagrams For Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Pilot Flame Copy of the Lighting Plate InstructionsBlower Thermodisc Gas Control ValveMaintenance Installing Glass Latch AdjustmentGlass Replacement Removing GlassFAN Maintenance Removing ValveReplacing Fan Maintenance Parts List U37 Main AssemblyU37 Burner & LOG Assembly U37 Door Assemblies Warranty ConditionsInstaller Please complete the following information
Related manuals
Manual 36 pages 55.81 Kb

U37-LP1, U37-NG1 specifications

The Regency U37-NG1 and U37-LP1 are two innovative models that showcase advanced technology and superior engineering in the realm of HVAC (heating, ventilation, and air conditioning) systems. These units are designed to deliver optimal comfort while maximizing energy efficiency, making them ideal for both residential and commercial applications.

One of the standout features of the U37-NG1 is its use of a high-efficiency burner system, which ensures that every unit is capable of delivering substantial heating output while consuming minimal gas. This not only translates to lower utility bills for users but also aligns with sustainability goals by reducing carbon emissions. In terms of design, the U37-NG1 is compact and can be installed in a variety of settings, making it a versatile choice for many different environments.

The U37-LP1, on the other hand, is tailored for propane applications, making it perfect for areas where natural gas is inaccessible. It features a similar high-efficiency heating output, ensuring that it meets the demands of users without compromising on performance. The dual-fuel capability of the U37 series enhances its adaptability, allowing it to be used in a range of scenarios.

Both models are equipped with advanced control technologies, including programmable thermostats and smart connectivity features. Users can easily manage their heating systems through mobile apps, allowing for remote adjustments and real-time monitoring. This technology not only enhances user convenience but also promotes energy conservation by allowing users to adjust settings based on their lifestyle and preferences.

In terms of durability, the Regency U37 series boasts a robust construction designed to withstand various environmental conditions. With quality materials and expert craftsmanship, these units are built to last, reducing the need for frequent repairs or replacements.

Overall, the Regency U37-NG1 and U37-LP1 models combine cutting-edge technology with practical features to deliver an exceptional heating experience. Their commitment to energy efficiency, adaptability, and user-friendly controls positions them as leading options in the HVAC market, making comfortable living spaces more accessible while promoting environmentally responsible practices. Whether for home use or commercial properties, these systems offer reliability and performance tailored to the needs of modern users.