RIGID PIPE VENTING - VERTICAL TERMINATIONS

FOR BOTH RESIDENTIAL & MANUFACTURED HOMES/MOBILE HOMES

Vertical Terminations

Vertical Terminations

with Co-linear Flex System

using Rigid Piping Systems

The shaded area in the diagram shows the allowable vertical terminations installed in a masonry chimney.All vertical vent instal- lations require the Vent Restrictor to be set to 1-1/4" (32mm) open.

Straight Vertical Terminations

The shaded areas in the two diagrams below show all allowable combinations of straight vertical and offset to vertical runs with vertical terminations. Maximum one 90o elbow. All vertical and offset to vertical vent installations require Vent Restrictor to be set to 1-1/4" (32mm) open. If the vent is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4" (32mm) clearance to combustibles.

Offset to Vertical Terminations

If using a Rigid Pipe Venting Sys- tem a rigid pipe adaptor #640-994 is required.

Rigid Pipe

Adapter

WARNING:

Do not combine venting components from different venting systems.

However use of the the AstroCapTM and FPI

Riser is acceptable with all systems.

This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with Duravent Direct-Vent GS, Selkirk Direct-Temp, Ameri Vent Direct venting and Security Secure Vent systems. Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing of components.

When using Rigid Vent other than

Simpson Dura-Vent, 3 screws must be used to secure rigid pipe to adaptor.

The FPI AstroCapTM and FPI Riser Vent terminal are certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent®Direct Vent GS, American Metal Products Ameri Vent Direct Vent, Security Secure Vent®, Selkirk Direct-Temp. Astro- CapTM is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct VentGSareregisteredand/orproprietarytrademarks of Simpson Dura-Vent Co. Inc.

Vent Restrictor Position

Vent restriction is required for certain venting installations, see the diagrams in "Venting Arrangment" section to deter- mine if they are required for your installation.

To set the Vent restriction as indicated in the diagram, simply loosen the screws and push the ventrestrictorplatetothecorrect position. Tighten the screws.

U37-1 Regency® ULTIMATE Rear Vent Direct Vent Freestanding Gas Stove

11

Image 11
Contents Ultimate U37 Rear Vent To the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Copy of Safety Label for U37 Safety LabelMA Code CO Detector RequirementsImportant Message Save These Instructions InstallationSpecifications General Safety InformationLocating Your GAS Stove Installation ChecklistManufactured Mobile Home Additional Requirements Clearances to CombustiblesExterior Vent Terminal Locations Planning Your Venting Installation Venting Installation PrecautionsSafety Precautions For the Installer SV4LB6 Rigid Pipe Venting Components ListVent Restrictor Position Using Rigid Piping SystemsStraight Vertical Terminations Offset to Vertical TerminationsSnorkel Terminations Horizontal TerminationsOptional Components Alternate Snorkel Termination CapHint Apply sealant to female end Below Grade Snorkel InstallationAlternate Approved Caps Vertical Termination with CO-LINEAR Flex SystemRequired Parts Description Converting a Factory Built Metal Chimney Approved for US Installations OnlyGeneral Converting Masonry Chimney Conversion Kit Contains Qty Conversion KIT# 514-969 from NG to LPInstallation of the DC Sparker Green ground wire High Elevation Aeration AdjustmentLOG SET Installation GAS ConnectionA02-65 Ports on the valve GAS Pipe Pressure TestingValve Description Thermocouple ConnectionFinal Check Louver InstallationOptional Remote Control Wall ThermostatWiring Diagrams For Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Gas Control Valve Copy of the Lighting Plate InstructionsBlower Thermodisc Pilot FlameMaintenance Removing Glass Latch AdjustmentGlass Replacement Installing GlassReplacing Fan FAN MaintenanceRemoving Valve Maintenance U37 Main Assembly Parts ListU37 Burner & LOG Assembly U37 Door Assemblies Conditions WarrantyInstaller Please complete the following information
Related manuals
Manual 36 pages 55.81 Kb

U37-LP1, U37-NG1 specifications

The Regency U37-NG1 and U37-LP1 are two innovative models that showcase advanced technology and superior engineering in the realm of HVAC (heating, ventilation, and air conditioning) systems. These units are designed to deliver optimal comfort while maximizing energy efficiency, making them ideal for both residential and commercial applications.

One of the standout features of the U37-NG1 is its use of a high-efficiency burner system, which ensures that every unit is capable of delivering substantial heating output while consuming minimal gas. This not only translates to lower utility bills for users but also aligns with sustainability goals by reducing carbon emissions. In terms of design, the U37-NG1 is compact and can be installed in a variety of settings, making it a versatile choice for many different environments.

The U37-LP1, on the other hand, is tailored for propane applications, making it perfect for areas where natural gas is inaccessible. It features a similar high-efficiency heating output, ensuring that it meets the demands of users without compromising on performance. The dual-fuel capability of the U37 series enhances its adaptability, allowing it to be used in a range of scenarios.

Both models are equipped with advanced control technologies, including programmable thermostats and smart connectivity features. Users can easily manage their heating systems through mobile apps, allowing for remote adjustments and real-time monitoring. This technology not only enhances user convenience but also promotes energy conservation by allowing users to adjust settings based on their lifestyle and preferences.

In terms of durability, the Regency U37 series boasts a robust construction designed to withstand various environmental conditions. With quality materials and expert craftsmanship, these units are built to last, reducing the need for frequent repairs or replacements.

Overall, the Regency U37-NG1 and U37-LP1 models combine cutting-edge technology with practical features to deliver an exceptional heating experience. Their commitment to energy efficiency, adaptability, and user-friendly controls positions them as leading options in the HVAC market, making comfortable living spaces more accessible while promoting environmentally responsible practices. Whether for home use or commercial properties, these systems offer reliability and performance tailored to the needs of modern users.