Regency U37-LP1, U37-NG1 installation manual U37 Door Assemblies

Page 34

PARTS LIST

 

 

U37 DOOR ASSEMBLIES

 

 

Part #

Description

 

 

730-923

Brush Nickel Mitred Door - Complete

 

 

730-924

Gold Mitred Door - Complete

 

 

730-926

Black Mitred Door - Complete

 

 

730-932

Gold Wrap Door - Complete

 

 

730-928

Gold Panel Door - Complete

 

 

 

101)

650-920

Door Gasket Kit

 

105)

*

Ceramic Paper

 

106)

940-323/P

Side Glass

 

107)

936-243

Glass Gasket

 

108)

940-322/P

Centre Glass

 

111)

*

Door Frame Fibre Paper

 

112)

750-015

Door Glass Extrusion

 

208)

940-325/P

Wrap Glass

 

*Not available as a replacement part.

34

U37-1 Regency® ULTIMATE Rear Vent Direct Vent Freestanding Gas Stove

Image 34
Contents Ultimate U37 Rear Vent Information for MOBILE/MANUFACTURED Homes After First Sale To the New OwnerTable of Contents Safety Label Copy of Safety Label for U37Requirements MA Code CO DetectorGeneral Safety Information InstallationSpecifications Important Message Save These InstructionsClearances to Combustibles Installation ChecklistManufactured Mobile Home Additional Requirements Locating Your GAS StoveExterior Vent Terminal Locations Safety Precautions For the Installer Venting Installation PrecautionsPlanning Your Venting Installation Rigid Pipe Venting Components List SV4LB6Offset to Vertical Terminations Using Rigid Piping SystemsStraight Vertical Terminations Vent Restrictor PositionAlternate Snorkel Termination Cap Horizontal TerminationsOptional Components Snorkel TerminationsBelow Grade Snorkel Installation Hint Apply sealant to female endRequired Parts Description Vertical Termination with CO-LINEAR Flex SystemAlternate Approved Caps General Approved for US Installations OnlyConverting a Factory Built Metal Chimney Converting Masonry Chimney Conversion KIT# 514-969 from NG to LP Conversion Kit Contains QtyInstallation of the DC Sparker Green ground wire GAS Connection Aeration AdjustmentLOG SET Installation High ElevationA02-65 Thermocouple Connection GAS Pipe Pressure TestingValve Description Ports on the valveWall Thermostat Louver InstallationOptional Remote Control Final CheckWiring Diagrams For Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Pilot Flame Copy of the Lighting Plate InstructionsBlower Thermodisc Gas Control ValveMaintenance Installing Glass Latch AdjustmentGlass Replacement Removing GlassRemoving Valve FAN MaintenanceReplacing Fan Maintenance Parts List U37 Main AssemblyU37 Burner & LOG Assembly U37 Door Assemblies Warranty ConditionsInstaller Please complete the following information
Related manuals
Manual 36 pages 55.81 Kb

U37-LP1, U37-NG1 specifications

The Regency U37-NG1 and U37-LP1 are two innovative models that showcase advanced technology and superior engineering in the realm of HVAC (heating, ventilation, and air conditioning) systems. These units are designed to deliver optimal comfort while maximizing energy efficiency, making them ideal for both residential and commercial applications.

One of the standout features of the U37-NG1 is its use of a high-efficiency burner system, which ensures that every unit is capable of delivering substantial heating output while consuming minimal gas. This not only translates to lower utility bills for users but also aligns with sustainability goals by reducing carbon emissions. In terms of design, the U37-NG1 is compact and can be installed in a variety of settings, making it a versatile choice for many different environments.

The U37-LP1, on the other hand, is tailored for propane applications, making it perfect for areas where natural gas is inaccessible. It features a similar high-efficiency heating output, ensuring that it meets the demands of users without compromising on performance. The dual-fuel capability of the U37 series enhances its adaptability, allowing it to be used in a range of scenarios.

Both models are equipped with advanced control technologies, including programmable thermostats and smart connectivity features. Users can easily manage their heating systems through mobile apps, allowing for remote adjustments and real-time monitoring. This technology not only enhances user convenience but also promotes energy conservation by allowing users to adjust settings based on their lifestyle and preferences.

In terms of durability, the Regency U37 series boasts a robust construction designed to withstand various environmental conditions. With quality materials and expert craftsmanship, these units are built to last, reducing the need for frequent repairs or replacements.

Overall, the Regency U37-NG1 and U37-LP1 models combine cutting-edge technology with practical features to deliver an exceptional heating experience. Their commitment to energy efficiency, adaptability, and user-friendly controls positions them as leading options in the HVAC market, making comfortable living spaces more accessible while promoting environmentally responsible practices. Whether for home use or commercial properties, these systems offer reliability and performance tailored to the needs of modern users.