Regency U37-LP1, U37-NG1 installation manual Copy of Safety Label for U37

Page 4

SAFETY LABEL

This is a copy of the label that accompanies each ULTIMATE Rear Vent Direct Vent Free- standing Gas Stove. We have printed a copy of the contents here for your review. The safety label is located on the inside of the drop down pedestal door.

NOTE: Regency® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.

Copy of Safety Label for U37

Listed: GRAVITY DIRECT VENT WALL FURNACE

Certified for/Certifiée pour: CANADA AND U.S.A.

Tested to: CGA 2-17-M91, ANSI Z21.88b-2003/CSA 2.33b-2003 REPORT NO. 476-1846-00 (Oct. 2000)

MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE

Serial No./No de serie

313

DO NOT REMOVE THIS LABEL /

NE PAS ENLEVER CETTE ÉTIQUETTE

 

 

FACTORYEQUIPPED FOR NATURALGAS: Model U37-NG1

ÉQUIPÉ À L'UISINE POUR GAZ NATURAL:

U37-NG1

Model/Modele:

Min. supply pressure

5.0"

WC/C.E. (1.24Kpa)

Pression d’alimentation minimum

Manifold pressure High

3.8"

WC/C.E. (0.947Kpa) Pression à la tubulure d’échappement élevée

Manifold pressure Low

1.1"

WC/C.E. (0.27Kpa)

Pression à la tubulure d’échappement élevée

 

 

 

 

Orifice size

#37

DMS

 

Dimensions de l’orifice

 

 

Altitude

0-4500

ft/pi

(0-1370m)

L’altitude

 

 

Maximum Input

30,000

Btu/h

(8.79Kw/h)

Débit calorifique maximum selon

 

 

Minimum Input

15,000

Btu/h

(4.39Kw/h)

Débit calorifique minimum selon

 

 

 

 

 

 

FACTORY EQUIPPED FOR PROPANE: Model U37-LP1

ÉQUIPÉ À L'UISINE POUR GAZ PROPANE:

 

 

Min. supply pressure

12"

WC/C.E. (3.00Kpa)

Pression d’alimentation minimum

U37-LP1

Model/Modele:

Manifold pressure High

11"

WC/C.E. (2.74Kpa)

Pression à la tubulure d’échappement élevée

Manifold pressure Low

2.9"

WC/C.E. (0.72Kpa)

Pression à la tubulure d’échappement élevée

 

 

 

 

Orifice size

#52

DMS

 

Dimensions de l’orifice

 

 

Altitude

0-4500

ft/pi

(0-1370m)

L’altitude

 

 

Maximum Input

30,000

Btu/h

(8.79Kw/h)

Débit calorifique maximum selon

 

 

Minimum Input

15,000

Btu/h

(4.39Kw/h)

Débit calorifique minimum selon

 

 

 

 

 

 

 

VENTING: Only for direct discharge without duct connection. This appliance must be installed in accordance with the manufacturer's installation instructions and with local codes, if any; if not, follow the current ANSI Z223.1 in the USA or the current CAN/CGA-B149 in Canada. For Manufactured Home Installation: This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada.

Electrical supply 115VAC, 1.13 A, 60 Hz. Not for use with solid fuel.

FPI Fireplace Products International Ltd., Delta, BC, Canada MADE IN CANADA / FABRIQUE AU CANADA

DOOR SEAL ADJUSTMENT:

Please check that door is properly sealed.

 

Periodic adjustment of latch may be required.

 

918-507

Minimum Clearances

to Combustibles/

Degagement Minimum

Des Materiaux

Combustibles

A7-1/2" /190 mm

B3" /76 mm

E 4-1/2" /114 mm

Min. Ceiling

Height from top of unit / Min. Plafond Hauteur en haut de l'appareil: 36" / 914 mm

For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the Commonwealth of Massachusetts.

For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.

For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.

The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed.

4

U37-1 Regency® ULTIMATE Rear Vent Direct Vent Freestanding Gas Stove

Image 4
Contents Ultimate U37 Rear Vent Information for MOBILE/MANUFACTURED Homes After First Sale To the New OwnerTable of Contents Safety Label Copy of Safety Label for U37Requirements MA Code CO DetectorInstallation SpecificationsGeneral Safety Information Important Message Save These InstructionsInstallation Checklist Manufactured Mobile Home Additional RequirementsClearances to Combustibles Locating Your GAS StoveExterior Vent Terminal Locations Safety Precautions For the Installer Venting Installation PrecautionsPlanning Your Venting Installation Rigid Pipe Venting Components List SV4LB6Using Rigid Piping Systems Straight Vertical TerminationsOffset to Vertical Terminations Vent Restrictor PositionHorizontal Terminations Optional ComponentsAlternate Snorkel Termination Cap Snorkel TerminationsBelow Grade Snorkel Installation Hint Apply sealant to female endRequired Parts Description Vertical Termination with CO-LINEAR Flex SystemAlternate Approved Caps General Approved for US Installations OnlyConverting a Factory Built Metal Chimney Converting Masonry Chimney Conversion KIT# 514-969 from NG to LP Conversion Kit Contains QtyInstallation of the DC Sparker Green ground wire Aeration Adjustment LOG SET InstallationGAS Connection High ElevationA02-65 GAS Pipe Pressure Testing Valve DescriptionThermocouple Connection Ports on the valveLouver Installation Optional Remote ControlWall Thermostat Final CheckWiring Diagrams For Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Copy of the Lighting Plate Instructions Blower ThermodiscPilot Flame Gas Control ValveMaintenance Latch Adjustment Glass ReplacementInstalling Glass Removing GlassRemoving Valve FAN MaintenanceReplacing Fan Maintenance Parts List U37 Main AssemblyU37 Burner & LOG Assembly U37 Door Assemblies Warranty ConditionsInstaller Please complete the following information
Related manuals
Manual 36 pages 55.81 Kb

U37-LP1, U37-NG1 specifications

The Regency U37-NG1 and U37-LP1 are two innovative models that showcase advanced technology and superior engineering in the realm of HVAC (heating, ventilation, and air conditioning) systems. These units are designed to deliver optimal comfort while maximizing energy efficiency, making them ideal for both residential and commercial applications.

One of the standout features of the U37-NG1 is its use of a high-efficiency burner system, which ensures that every unit is capable of delivering substantial heating output while consuming minimal gas. This not only translates to lower utility bills for users but also aligns with sustainability goals by reducing carbon emissions. In terms of design, the U37-NG1 is compact and can be installed in a variety of settings, making it a versatile choice for many different environments.

The U37-LP1, on the other hand, is tailored for propane applications, making it perfect for areas where natural gas is inaccessible. It features a similar high-efficiency heating output, ensuring that it meets the demands of users without compromising on performance. The dual-fuel capability of the U37 series enhances its adaptability, allowing it to be used in a range of scenarios.

Both models are equipped with advanced control technologies, including programmable thermostats and smart connectivity features. Users can easily manage their heating systems through mobile apps, allowing for remote adjustments and real-time monitoring. This technology not only enhances user convenience but also promotes energy conservation by allowing users to adjust settings based on their lifestyle and preferences.

In terms of durability, the Regency U37 series boasts a robust construction designed to withstand various environmental conditions. With quality materials and expert craftsmanship, these units are built to last, reducing the need for frequent repairs or replacements.

Overall, the Regency U37-NG1 and U37-LP1 models combine cutting-edge technology with practical features to deliver an exceptional heating experience. Their commitment to energy efficiency, adaptability, and user-friendly controls positions them as leading options in the HVAC market, making comfortable living spaces more accessible while promoting environmentally responsible practices. Whether for home use or commercial properties, these systems offer reliability and performance tailored to the needs of modern users.