Regency U37-NG1 Installation Checklist, Manufactured Mobile Home Additional Requirements, Venting

Page 7

INSTALLATION

INSTALLATION

CHECKLIST

1)Locate your appliance. Refer to the following sections:

a.Clearances to Combustibles

b.Locating your Ultimate Gas Stove

c."Venting" to "Rigid Pipe Venting - Vertical Terminations" sections.

2)Install venting. See "Planning Your Venting Installation" to "Vertical Termination with Co-Linear Flex System" sections.

3)Make gas connections. Refer to the "Gas Connection" section.

Test the pilot. Must be as per diagram in the "Maintenance Instructions" section.

4)If necessary, convert from Natural Gas to Propane. Refer to the "Conversion Kit from NG to LPG" section.

5)Installl standard and optional features. Refer to the following sections where applicable:

a.Log Set Installation

b.Door Installation

c.Louver Installation

d.Wall Thermostat

e.Remote Control

6)Final check. Refer to the "Final Check" sec- tion.

Before leaving this unit with the customer, the installer must ensure that the appliance is fi r- ing correctly and operation fully explained

to customer.

This includes:

1)Clocking the appliance to ensure the correct fi ring rate (rate noted on label) after burning appliance for 15 minutes.

2)Ifrequired,adjustingtheprimaryairtoensure that the fl ame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer.

MANUFACTURED

MOBILE HOME

ADDITIONAL

REQUIREMENTS

1)Ensure that structural members are not cut or weakened during installation.

2)Ensure proper grounding using the #8 ground lug provided.

3)Appliance must be anchored to the fl oor with the supplied anchoring methods.

CLEARANCES TO

COMBUSTIBLES

The clearances listed are MINIMUM distances. Measure the clearance to both the appliance and the chimney connector. The farthest distance is correct if the two clearances do not coincide. For example, if the appliance is set as indicated in one of the diagrams but the connector is too close, move the stove until the correct clearance to the connector is obtained.

This appliance may be installed only with the clearances as shown in the situations pictured.

Do not combine clearances from one type of installation with another in order to achieve closer clearances.

This unit can be installed on a solid combustible surface like a wood fl oor. This unit can also be installed directly on carpeting or vinyl when the bottom pedestal cover plate (provided with unit ) is installed.

Use the minimum clearances shown in the dia- grams below:

Clearances

 

A Side Wall to Unit

7-1/2" / 190 mm

B Back Wall to Unit

3" / 76 mm

E Side Wall to Unit

4-1/2" / 114 mm

 

Reference Dimensions

C Floor to Flue Centerline

25" / 635 mm

D SideWall to Flue Centerline20-1/2" / 521 mm

Minimumceilingheight

is 36" / 914 mm from

top of unit.

LOCATING YOUR

GAS STOVE

When selecting a location for your stove, ensure that the clearances listed above are met as well as ensuring that there is adequate accessibility for servicing and proper operation.

For Vent Termination requirements, see the "Exterior Vent Terminal Locations" section.

This appliance is Listed for bedroom installations when used with a Listed Millivolt Thermostat. Some areas may have further requirements, check local codes before installation.

This appliance is Listed for Alcove installations, maintain minimumAlcove clearances as follows, minimum ceiling height of 66"(1.7m), minimum width of 41"(1.0m) and a maximum depth of 36"(0.9m).

A) Cross Corner

B)Flush with Wall/Alcove

C) Flat on Wall Corner

D)Flat on Wall

COMBUSTION AND VENTILATION AIR

The combustion air from this appliance is drawn from outside the building through the outer fl ue.

Extra provision for combustion air inside the room is not required.

VENTING

The Regency® Direct Vent System (Horizontal Termination Kit (640-944) and the Vertical Termination with the Co-linear Flex System in combination with the ULTIMATE Direct Vent- Rear Freestanding Gas Stoves (U37-NG1 and U37-LP1) have been tested and listed as direct vent heater systems by Warnock Hersey.

The Horiz. Termination Kit (640-944) includes everything required for a straight through the wall installation, or add a 45o elbow for a corner installation. If a snorkel termination is required, the Simpson Dura-Vent Direct Vent System Model DVGS terminals are available.

U37-1 Regency® ULTIMATE Rear Vent Direct Vent Freestanding Gas Stove

7

Image 7
Contents Ultimate U37 Rear Vent To the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Copy of Safety Label for U37 Safety LabelMA Code CO Detector RequirementsImportant Message Save These Instructions InstallationSpecifications General Safety InformationLocating Your GAS Stove Installation ChecklistManufactured Mobile Home Additional Requirements Clearances to CombustiblesExterior Vent Terminal Locations Safety Precautions For the Installer Venting Installation PrecautionsPlanning Your Venting Installation SV4LB6 Rigid Pipe Venting Components ListVent Restrictor Position Using Rigid Piping SystemsStraight Vertical Terminations Offset to Vertical TerminationsSnorkel Terminations Horizontal TerminationsOptional Components Alternate Snorkel Termination CapHint Apply sealant to female end Below Grade Snorkel InstallationRequired Parts Description Vertical Termination with CO-LINEAR Flex SystemAlternate Approved Caps General Approved for US Installations OnlyConverting a Factory Built Metal Chimney Converting Masonry Chimney Conversion Kit Contains Qty Conversion KIT# 514-969 from NG to LPInstallation of the DC Sparker Green ground wire High Elevation Aeration AdjustmentLOG SET Installation GAS ConnectionA02-65 Ports on the valve GAS Pipe Pressure TestingValve Description Thermocouple ConnectionFinal Check Louver InstallationOptional Remote Control Wall ThermostatWiring Diagrams For Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Gas Control Valve Copy of the Lighting Plate InstructionsBlower Thermodisc Pilot FlameMaintenance Removing Glass Latch AdjustmentGlass Replacement Installing GlassRemoving Valve FAN MaintenanceReplacing Fan Maintenance U37 Main Assembly Parts ListU37 Burner & LOG Assembly U37 Door Assemblies Conditions WarrantyInstaller Please complete the following information
Related manuals
Manual 36 pages 55.81 Kb

U37-LP1, U37-NG1 specifications

The Regency U37-NG1 and U37-LP1 are two innovative models that showcase advanced technology and superior engineering in the realm of HVAC (heating, ventilation, and air conditioning) systems. These units are designed to deliver optimal comfort while maximizing energy efficiency, making them ideal for both residential and commercial applications.

One of the standout features of the U37-NG1 is its use of a high-efficiency burner system, which ensures that every unit is capable of delivering substantial heating output while consuming minimal gas. This not only translates to lower utility bills for users but also aligns with sustainability goals by reducing carbon emissions. In terms of design, the U37-NG1 is compact and can be installed in a variety of settings, making it a versatile choice for many different environments.

The U37-LP1, on the other hand, is tailored for propane applications, making it perfect for areas where natural gas is inaccessible. It features a similar high-efficiency heating output, ensuring that it meets the demands of users without compromising on performance. The dual-fuel capability of the U37 series enhances its adaptability, allowing it to be used in a range of scenarios.

Both models are equipped with advanced control technologies, including programmable thermostats and smart connectivity features. Users can easily manage their heating systems through mobile apps, allowing for remote adjustments and real-time monitoring. This technology not only enhances user convenience but also promotes energy conservation by allowing users to adjust settings based on their lifestyle and preferences.

In terms of durability, the Regency U37 series boasts a robust construction designed to withstand various environmental conditions. With quality materials and expert craftsmanship, these units are built to last, reducing the need for frequent repairs or replacements.

Overall, the Regency U37-NG1 and U37-LP1 models combine cutting-edge technology with practical features to deliver an exceptional heating experience. Their commitment to energy efficiency, adaptability, and user-friendly controls positions them as leading options in the HVAC market, making comfortable living spaces more accessible while promoting environmentally responsible practices. Whether for home use or commercial properties, these systems offer reliability and performance tailored to the needs of modern users.