Regency U35-NG1, U35-LP1 installation manual Maintenance

Page 22

MAINTENANCE

MAINTENANCE

INSTRUCTIONS

1)Always turn the gas valve to off before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year.

When cleaning the logs, use a clean soft paint brush as the logs are fragile and easily damaged.

2)Clean (never when unit is hot) appliance, door and louvers with a damp cloth. Never use an abrasive cleaner. The gold louvers (and optional gold door) may be scratched if abrasives are used to clean them.

The heater is finished in a heat resistant paint and should only be refinished with heat resistant paint (not with wall paint). FPI uses StoveBrite Paint - Metallic Black #6309.

3)Make a periodic check of burner for proper position and condition. Visually check the flame of the burner periodically, making sure the flames are steady; not lifting or floating. If there is a problem, call a qualified service person.

4)The appliance and venting system must be inspected before use, and at least annually, by a qualified field service person, to ensure that the flow of combustion and ventilation air is not obstructed.

During the annual service call, the burners should be removed from the burner tray and cleaned. Replace the embers but do not block the pilot.

5)Keep the area near the appliance clear and free from combustible materials, gasoline and other flammable vapours and liquids.

WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURE AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

CAUTION: ANYSAFETYSCREEN OR GUARD REMOVED FOR SERVICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE.

C L O T H I N G O R O T H E R FLAMMABLEMATERIALSHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.

6)Each time the appliance is lit, it may cause condensation and fog the glass. This condensation and fog is normal and will disappear in a few minutes as the glass heats up.

Never operate the appliance without the glass properly secured in place or with the door open.

7)Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace nay part of the control system and any gas control which has been under water.

8)Periodically check the pilot flames. Correct flame pattern has three strong blue flames: 1 flowing around the thermopile and 1 around the thermocouple, and 1 flowing across the rear of the burner (it does not have to be touching the burner).

Note: Ifyouhaveanincorrectflamepattern, contact your FPI dealer for further instructions.

Top View of pilot flame

Incorrect flame pattern will have small, probably yellow flames, not coming into proper contact with the rear of the burner or thermopile.

Top View of pilot flame

GENERAL VENT

MAINTENANCE

Conduct an inspection of the venting system semi-annually. Recommended areas to inspect as follows:

1)Check the Venting System for corrosion in areas that are exposed to the elements. These will appear as rust spots or streaks, and in extreme cases, holes. These components should be replaced immediately.

2)Remove the Termination Cap, and shine a flashlight down the Vent. Remove any bird nests, or other foreign material.

3)Check for evidences of excessive condensation, such as water droplets forming in the inner liner, and subsequently dripping out the joints, Continuous condensation can cause corrosion of caps, pipe, and fittings. It may be caused by having excessive lateral runs, too many elbows, and exterior portions of the system being exposed to cold weather.

4)Inspect joints, to verify that no pipe sections or fittings have been disturbed, and consequently loosened.Also check mechanical supports such as Wall Straps, or plumbers' tape for rigidity.

LOG REPLACEMENT

The unit should never be used with broken logs.Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs. The pilot light generates enough heat to burn someone. If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagram under Log Installation.

NOTE: Improper positioning of logs may create carbon build-up and will alter the unit’s performance which is not covered under warranty.

GLASS GASKET

If the glass gasket requires replacement use glass gasket (Part # 936-265) for the Bay Front and a tadpole gasket for the Flush Front (Part # 936-155).

STEEL OR GOLD TRIM

The steel or 24 carat gold plated finish on the trim requires little maintenance, and need only be cleaned with a damp cloth. DO NOT use abrasive materials or chemical cleaners, as they may harm the finish and void the warranty.

22

U35 FPI Direct Vent Gas Insert

Image 22
Contents U35 Gas Insert FPI GAS Fireplace Insert U35 FPI Direct Vent Gas InsertTable of Contents Safety Label Requirements MA Code CO DetectorInstallation Minimum Fireplace Dimensions Installation ChecklistMaterials Required Minimum Clearances to Combustibles GAS Connection Flue Liner InstallationVenting Optional Brick Panel GAS Pipe Pressure TestingGAS Insert Aeration System SIT Valve DescriptionRear View Faceplate Assembly Diagram LOG InstallationFaceplate & Trim Installation Hint Install the front right side firstFlush Louvers Standard Flush DoorOptional Flush Trim Hinge Location Bottom LouverDouble Screen Doors Optional BAY DoorOptional BAY Trim BAY LouversKensington Front Screws Kensington Front InstallationBlanking Plate Tabs Kensington Front Screw Panel Door Installation Glass Door Sub-Frame HookFull Screen Doors Hinge Wiring Diagrams Optional Remote Control Optional Wall ThermostatOperating Instructions Automatic Convection FAN Operation Copy of Lighting Instruction PlateNormal Operating Sounds GAS Appliances Maintenance Bay Glass Replacement FAN MaintenanceFlush Glass Replacement Door GlassReplacing fan Removing ValveShut off the gas supply Installing Valve Left Valve Bracket RightParts List Main AssemblyBurner & LOG Assembly Bay Front Flush Door and BAY Front AssemblyFlush Front Parts List FACEPLATES, TRIMS, and HearthsU35 FPI Direct Vent Gas Insert Warranty ConditionsInstaller Please complete the following information

U35-NG1, U35-LP1 specifications

The Regency U35-LP1 and U35-NG1 are cutting-edge gas fireplace inserts designed to elevate both the aesthetic and functional appeal of any home. Both models represent a blend of modern technology and classic design, making them perfect for those who desire warmth without sacrificing style.

One of the main features of the Regency U35 series is its impressive heat output. With the capability of delivering up to 30,000 BTUs, these inserts efficiently heat medium to large spaces, ensuring comfort even in the coldest months. The U35-LP1 operates on propane, while the U35-NG1 utilizes natural gas, providing flexibility in fuel choice based on the homeowner's needs.

Another distinctive characteristic of the U35 fireplace inserts is their large viewing area, featuring a panoramic glass front that maximizes the fire's visibility. This design is not only visually appealing but also adheres to safety standards, as the glass remains cool to the touch, making it suitable for households with children or pets. The flame presentation is further enhanced by the realistic logs and ember bed, creating an inviting ambiance that replicates a traditional wood-burning fire.

Technologically, these fireplaces are equipped with advanced features such as a programmable remote control, enabling users to adjust the flame height and heat output with ease. Additionally, the inserts come with an optional wall switch control, providing further convenience in managing the fire. Energy efficiency is another hallmark of the U35 series, as they meet or exceed the EPA's standards, ensuring minimal emissions and lower energy costs.

Installation is simplified thanks to the flexible venting options available with both models. Homeowners can choose from straight, horizontal, or vertical venting configurations, making it easier to integrate the fireplace into various home layouts. Furthermore, both models come with a limited lifetime warranty, reflecting Regency's commitment to quality and reliability.

In conclusion, the Regency U35-LP1 and U35-NG1 are exceptional gas fireplace inserts that combine aesthetic elegance with functional efficiency. With their impressive heat output, user-friendly controls, and stylish designs, they stand out as exceptional choices for anyone looking to enhance their living space with the warmth and charm of a beautiful fire.