REQUIREMENTS

MA Code - CO Detector

(for the State of Massachusetts only)

5.08: Modifications to NFPA-54, Chapter 10

(2) Revise 10.8.3 by adding the following additional requirements:

(a)For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:

1.INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors

a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

2.APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.

3.SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight

(8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL

OBSTRUCTIONS".

4.INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.

(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:

1.The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by the Board; and

2.Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.

(c)MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:

1.Detailed instructions for the installation of the venting system design or the venting system components; and

2.A complete parts list for the venting system design or venting system.

(d)MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies "special venting systems", the following requirements shall be satisfied by the manufacturer:

1.The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and

2.The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.

(e)A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.

U35 FPI Direct Vent Gas Insert

5

 

Image 5
Contents U35 Gas Insert U35 FPI Direct Vent Gas Insert FPI GAS Fireplace InsertTable of Contents Safety Label MA Code CO Detector RequirementsInstallation Materials Required Installation ChecklistMinimum Fireplace Dimensions Minimum Clearances to Combustibles Venting Flue Liner InstallationGAS Connection GAS Insert Aeration System GAS Pipe Pressure TestingOptional Brick Panel SIT Valve DescriptionFaceplate & Trim Installation LOG InstallationRear View Faceplate Assembly Diagram Hint Install the front right side firstOptional Flush Trim Standard Flush DoorFlush Louvers Hinge Location Bottom LouverOptional BAY Trim Optional BAY DoorDouble Screen Doors BAY LouversBlanking Plate Tabs Kensington Front Screw Kensington Front InstallationKensington Front Screws Glass Door Sub-Frame Hook Panel Door InstallationFull Screen Doors Hinge Wiring Diagrams Thermostat Optional Remote Control Optional WallOperating Instructions Normal Operating Sounds GAS Appliances Copy of Lighting Instruction PlateAutomatic Convection FAN Operation Maintenance Flush Glass Replacement FAN MaintenanceBay Glass Replacement Door GlassShut off the gas supply Removing ValveReplacing fan Left Valve Bracket Right Installing ValveMain Assembly Parts ListBurner & LOG Assembly Flush Front Flush Door and BAY Front AssemblyBay Front FACEPLATES, TRIMS, and Hearths Parts ListU35 FPI Direct Vent Gas Insert Conditions WarrantyInstaller Please complete the following information

U35-NG1, U35-LP1 specifications

The Regency U35-LP1 and U35-NG1 are cutting-edge gas fireplace inserts designed to elevate both the aesthetic and functional appeal of any home. Both models represent a blend of modern technology and classic design, making them perfect for those who desire warmth without sacrificing style.

One of the main features of the Regency U35 series is its impressive heat output. With the capability of delivering up to 30,000 BTUs, these inserts efficiently heat medium to large spaces, ensuring comfort even in the coldest months. The U35-LP1 operates on propane, while the U35-NG1 utilizes natural gas, providing flexibility in fuel choice based on the homeowner's needs.

Another distinctive characteristic of the U35 fireplace inserts is their large viewing area, featuring a panoramic glass front that maximizes the fire's visibility. This design is not only visually appealing but also adheres to safety standards, as the glass remains cool to the touch, making it suitable for households with children or pets. The flame presentation is further enhanced by the realistic logs and ember bed, creating an inviting ambiance that replicates a traditional wood-burning fire.

Technologically, these fireplaces are equipped with advanced features such as a programmable remote control, enabling users to adjust the flame height and heat output with ease. Additionally, the inserts come with an optional wall switch control, providing further convenience in managing the fire. Energy efficiency is another hallmark of the U35 series, as they meet or exceed the EPA's standards, ensuring minimal emissions and lower energy costs.

Installation is simplified thanks to the flexible venting options available with both models. Homeowners can choose from straight, horizontal, or vertical venting configurations, making it easier to integrate the fireplace into various home layouts. Furthermore, both models come with a limited lifetime warranty, reflecting Regency's commitment to quality and reliability.

In conclusion, the Regency U35-LP1 and U35-NG1 are exceptional gas fireplace inserts that combine aesthetic elegance with functional efficiency. With their impressive heat output, user-friendly controls, and stylish designs, they stand out as exceptional choices for anyone looking to enhance their living space with the warmth and charm of a beautiful fire.