Regency P40-NG, P40-LP Rigid Pipe Venting Systems, Basic Horizontal & Vertical Terminations

Page 15

INSTALLATION

RIGID PIPE VENTING SYSTEMS

BASIC HORIZONTAL & VERTICAL TERMINATIONS

Rigid Pipe Vent Systems offer a complete line of component parts for installation of both horizontal and vertical installations. Many items are offered in decorative black, as well as galvanized fi nish.

INSTALLATION

The minimum components required for a basic horizontal termination are:

1Horizontal Termination Cap

190o Elbow

1Rigid Pipe Adaptor

1Wall Thimble (Canada only)

1Length of pipe to suit wall thickness

The minimum components required for a basic vertical termination are:

1Vertical Termination Cap

1Rigid Pipe Adaptor

1Lengths of pipe to adequately penetrate roof

1Ceiling Firestop

1Flashing

1Storm Collar

Wall thickness is measured from the back standoffs to the inside mounting surface of termination cap. For siding other than vinyl furring strips may be used, instead of the vinyl siding standoff, to create a level surface to mount the vent terminal. The Terminal must not be recessed into siding. Measure the wall thickness including furring strips.

If a Vinyl Siding Standoff is required (it must be used with vinyl siding), measure to outside surface of wall without siding and add 2 inches.

When using Rigid Vent other than

Simpson Dura-Vent, 3 screws must be used to secure rigid pipe to adaptor.

Vertical

Terminal

Storm Collar

 

Vinyl Siding

Flashing

Standoff

AstroCap XL

Ceiling FirestopTermination Cap (946-623/P)

 

 

Wall Thimble

 

 

(required in Canada only)

Pipe Length

Adj.Pipe Length

 

 

11" - 14-5/8"

90o Elbow

 

 

24" Pipe

 

 

Length

 

Alternate

 

 

Horizontal Termination

Rigid Pipe Adapter

Caps

 

(770-994)

 

WARNING:

Do not combine venting components from different venting systems.

Use of the the AstroCap XLTM and FPI Riser is acceptable with all systems.

This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with Duravent Direct-Vent GS and Selkirk Direct- Temp systems. Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing of components.

The FPI AstroCap XLTM is certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent®Direct Vent GS and Selkirk Direct-Temp. AstroCap XLTM is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.

Regency® P40 Direct Vent Gas Fireplace

15

Image 15
Contents P40 Gas Fireplace Information for MOBILE/MANUFACTURED Homes After First Sale Manufactured Mobile Home RequirementsTable of Contents Copy of Safety Label Safety LabelMA Code CO Detector RequirementsUnit Dimensions Important Message Save These Instructions InstallationGeneral Safety Information Installation ChecklistLocating Your GAS Fireplace Manufactured Mobile Home Additional RequirementsHeat Release KIT Hearth RequirementsClearances Mantel LEG Clearances Mantel ClearancesHeight = 42-1/2 plus height of hearth Framing & FinishingScrew Unit Assembly Prior to InstallationVenting Introduction Vent Restrictor PositionExterior Vent Termination Requirements InstallationHorizontal Termination Flex Venting ArrangementsBasic Horizontal & Vertical Terminations Rigid Pipe Venting SystemsRigid Pipe Adaptor Must use with all Rigid Piping Rigid Pipe Venting Components ListVertical Height Feet Allowable Horizontal TerminationsHorizontal Venting with Two 2 90o Elbows Vertical Venting with Two 2 90o Elbows Vent must be supported at offsets Allowable Vertical TerminationsArrow on the vent cap should be pointing up Unit Installation with Horizontal TerminationMinimum Vent Unit Installation With Vertical TerminationThis allows for small adjustments DiagramAstrocap XL Dimensions Unit InstallationP40-NG System Data GAS Line InstallationPilot Adjustment High ElevationPower Module GAS Pipe Pressure TestingBACK-UP Battery Installation Unplug the power sourceLP Conversion Kit Contains Qty Description Conversion KIT #502-969 from NG to LPControl Module Back Brick Panel Brick Panel InstallationEnsure that the logs are not in the unit Top Brick PanelEmber Bed LOG SET InstallationEmber Bed Completed Log Set Installation Flush Louvers Aeration AdjustmentInstalling the Manual Control Box Standard Flush DoorWiring Diagram Finishing TrimDo not cut the ground terminal off under any circumstances First Fire Lightingshutdown Procedure ProcedureOperating Instructions Operating InstructionsOperation During Power Outage Firewizardtm Remote Control FunctionsSummary Controls Copy Lighting Plate Instructions Normal Operating Sounds GAS AppliancesMaintenance Control Module FAN ReplacementSolenoid Valve Front Air Box Valve ReplacementFender Back BurnerDC Sparker Replacement Heat Shield Power Module ReplacementControl Module Replacement Backup Battery ReplacementParts List Main AssemblyDescription Valve Tray Assembly Flush Door & Louvers Regency P40 Direct Vent Gas Fireplace Regency P40 Direct Vent Gas Fireplace Warranty Limited Lifetime WarrantyInstaller Please complete the following information

P40, P40-LP, P40-NG specifications

The Regency P40 series, comprising the P40-LP, P40, and P40-NG models, represents a significant advancement in the world of portable radio communications. Designed with both versatility and performance in mind, these devices cater to a diverse range of users, from public safety professionals to outdoor enthusiasts.

One of the standout features of the P40 series is its robust build quality. The radios are engineered to withstand harsh environments, boasting IP67 water and dust resistance ratings. This ensures reliable performance even in challenging conditions, making them ideal for emergency responders who operate in adverse weather or rugged terrains. The P40's durable design is complemented by a lightweight construction, allowing for prolonged use without fatigue.

The P40 series is equipped with advanced digital technology that enhances both audio clarity and range. With a powerful speaker and noise-canceling capabilities, users can communicate clearly even in noisy surroundings. The P40-NG model takes this a step further by incorporating digital signal processing (DSP) technology, which optimizes sound for both transmission and reception.

Battery life is a critical aspect of any portable device, and the P40 series excels in this regard. With options for high-capacity lithium-ion batteries, users can expect extended operational times, vital for those on long shifts or field operations. Additionally, the smart battery management system provides real-time battery status updates, ensuring users are never caught off guard.

Interoperability is another key characteristic of the P40 series. The radios support multiple frequency bands and can seamlessly integrate with existing communication infrastructures. This capability is particularly beneficial for agencies that require coordination across various channels and networks.

User-friendly interfaces define the P40 series, with intuitive controls and customizable features. The color display on the P40 and P40-NG models enhances usability, allowing for easy navigation through settings and features. Furthermore, programmable buttons facilitate quick access to frequently used functions, ensuring efficient communication even in high-pressure scenarios.

Overall, the Regency P40-LP, P40, and P40-NG radios embody reliability, advanced technology, and ruggedness, making them essential tools for effective communication in a variety of demanding environments. With their combination of durability, audio performance, and battery life, these radios stand out as a top choice for both professional and recreational use.