Regency P40-NG, P40-LP installation manual Table of Contents

Page 3

TABLE OF CONTENTS

SAFETY LABEL

 

Copy of Safety Label

4

REQUIREMENTS

 

MA Code - CO Detector

 

(for state of Massachusetts only)

5

UNIT DIMENSIONS

 

Dimensions

6

INSTALLATION

 

Important Message

7

Before You Start

7

General Safety Information

7

Installation Checklist

7

Manufactured Mobile Home Additional Requirements ..

8

Locating Your Gas Fireplace

8

Heatwave Duct Kit

8

Heat Release Kit

8

Hearth Requirements

8

Clearances

9

Mantel Clearances

10

Mantel Leg Clearances

10

Framing & Finishing

11

Unit Assembly Prior To Installation

12

Top Standoff Assembly

12

Top Facing Support and Side Nailing Strips

12

Venting Introduction

12

Vent Restrictor Position

12

Exterior Vent Termination Requirements

13

Venting Arrangements

14

Horizontal Termination (Flex)

14

Rigid Pipe Venting Systems

15

Basic Horizontal & Vertical Terminations

15

Rigid Pipe Venting Components List

16

Venting Arrangements

17

Allowable Horizontal Terminations

17

Venting Arrangements

20

Allowable Vertical Terminations

20

Unit Installation with Horizontal Termination

21

Unit Installation with Vertical Termination

22

Horizontal Termination with Flex Vent System

23

P40-NG System Data

24

P40-LP System Data

24

High Elevation

24

Gas Line Installation

24

Pilot Adjustment

24

Gas Pipe Pressure Testing

25

SIT Valve Description

25

Back-Up Battery Installation

25

Conversion Kit #502-969 from NG to LP

26

Brick Panel Installation

28

Log Set Installation

29

Aeration Adjustment

32

Standard Flush Door

32

Flush Louvers

32

Finishing Trim

33

Wiring Diagram

33

OPERATING INSTRUCTIONS

 

Operating Instructions

34

Shutdown Procedure

34

First Fire

34

Lighting Procedure

34

Operation During Power Outage

35

Summary Of Controls

35

FireWizardTM Remote Control Functions

35

Normal Operating Sounds of Gas Appliances

36

Copy of Lighting Plate Instructions

36

MAINTENANCE

 

Maintenance Instructions

37

General Vent Maintenance

37

Log Replacement

37

Thermopile / Thermocouple

37

Glass Gasket

37

Louvers

37

Door Glass

38

Glass Replacement

38

Fan Replacement

38

Valve Replacement

39

DC Sparker Replacement

40

Power Module Replacement

41

Control Module Replacement

41

Backup Battery Replacement

41

PARTS LIST

 

Main Assembly

42

Valve Tray Assembly

43

Flush Door & Louvers

44

WARRANTY

 

The Warranty: Limited Lifetime

47

Regency® P40 Direct Vent Gas Fireplace

3

Image 3
Contents P40 Gas Fireplace Information for MOBILE/MANUFACTURED Homes After First Sale Manufactured Mobile Home RequirementsTable of Contents Copy of Safety Label Safety LabelMA Code CO Detector RequirementsUnit Dimensions Important Message Save These Instructions InstallationGeneral Safety Information Installation ChecklistLocating Your GAS Fireplace Manufactured Mobile Home Additional RequirementsHeat Release KIT Hearth RequirementsClearances Mantel LEG Clearances Mantel ClearancesHeight = 42-1/2 plus height of hearth Framing & FinishingScrew Unit Assembly Prior to InstallationVenting Introduction Vent Restrictor PositionExterior Vent Termination Requirements InstallationHorizontal Termination Flex Venting ArrangementsBasic Horizontal & Vertical Terminations Rigid Pipe Venting SystemsRigid Pipe Adaptor Must use with all Rigid Piping Rigid Pipe Venting Components ListVertical Height Feet Allowable Horizontal TerminationsHorizontal Venting with Two 2 90o Elbows Vertical Venting with Two 2 90o Elbows Vent must be supported at offsets Allowable Vertical TerminationsArrow on the vent cap should be pointing up Unit Installation with Horizontal TerminationMinimum Vent Unit Installation With Vertical TerminationThis allows for small adjustments DiagramAstrocap XL Dimensions Unit InstallationP40-NG System Data GAS Line InstallationPilot Adjustment High ElevationPower Module GAS Pipe Pressure TestingBACK-UP Battery Installation Unplug the power sourceLP Conversion Kit Contains Qty Description Conversion KIT #502-969 from NG to LPControl Module Back Brick Panel Brick Panel InstallationEnsure that the logs are not in the unit Top Brick PanelEmber Bed LOG SET InstallationEmber Bed Completed Log Set Installation Flush Louvers Aeration AdjustmentInstalling the Manual Control Box Standard Flush DoorWiring Diagram Finishing TrimDo not cut the ground terminal off under any circumstances First Fire Lightingshutdown Procedure ProcedureOperating Instructions Operating InstructionsOperation During Power Outage Firewizardtm Remote Control FunctionsSummary Controls Copy Lighting Plate Instructions Normal Operating Sounds GAS AppliancesMaintenance Control Module FAN ReplacementSolenoid Valve Front Air Box Valve ReplacementFender Back BurnerDC Sparker Replacement Heat Shield Power Module ReplacementControl Module Replacement Backup Battery ReplacementParts List Main AssemblyDescription Valve Tray Assembly Flush Door & Louvers Regency P40 Direct Vent Gas Fireplace Regency P40 Direct Vent Gas Fireplace Warranty Limited Lifetime WarrantyInstaller Please complete the following information

P40, P40-LP, P40-NG specifications

The Regency P40 series, comprising the P40-LP, P40, and P40-NG models, represents a significant advancement in the world of portable radio communications. Designed with both versatility and performance in mind, these devices cater to a diverse range of users, from public safety professionals to outdoor enthusiasts.

One of the standout features of the P40 series is its robust build quality. The radios are engineered to withstand harsh environments, boasting IP67 water and dust resistance ratings. This ensures reliable performance even in challenging conditions, making them ideal for emergency responders who operate in adverse weather or rugged terrains. The P40's durable design is complemented by a lightweight construction, allowing for prolonged use without fatigue.

The P40 series is equipped with advanced digital technology that enhances both audio clarity and range. With a powerful speaker and noise-canceling capabilities, users can communicate clearly even in noisy surroundings. The P40-NG model takes this a step further by incorporating digital signal processing (DSP) technology, which optimizes sound for both transmission and reception.

Battery life is a critical aspect of any portable device, and the P40 series excels in this regard. With options for high-capacity lithium-ion batteries, users can expect extended operational times, vital for those on long shifts or field operations. Additionally, the smart battery management system provides real-time battery status updates, ensuring users are never caught off guard.

Interoperability is another key characteristic of the P40 series. The radios support multiple frequency bands and can seamlessly integrate with existing communication infrastructures. This capability is particularly beneficial for agencies that require coordination across various channels and networks.

User-friendly interfaces define the P40 series, with intuitive controls and customizable features. The color display on the P40 and P40-NG models enhances usability, allowing for easy navigation through settings and features. Furthermore, programmable buttons facilitate quick access to frequently used functions, ensuring efficient communication even in high-pressure scenarios.

Overall, the Regency P40-LP, P40, and P40-NG radios embody reliability, advanced technology, and ruggedness, making them essential tools for effective communication in a variety of demanding environments. With their combination of durability, audio performance, and battery life, these radios stand out as a top choice for both professional and recreational use.