Regency P33-NG4 Unit Installation with Horizontal Termination, Snorkel Terminations, Lock joint

Page 24

INSTALLATION

UNIT INSTALLATION WITH HORIZONTAL TERMINATION

Install the vent system according to the manufacturer's instructions included with the components.

1) Set the unit in its desired location. Check

to determine if wall studs or roof rafters

are in the way when the venting system is

attached. If this is the case, you may want

to adjust the location of the unit. Rough in

the gas preferably on the right side of the

unit and the electrical (junction block is on

the left side) on the left.

2) Direct Vent pipe and fi ttings are designed

with special twist-lock connections to

b) Horizontal runs of

vent must be

Diagram 2a

supported every three feet. Wall straps

 

are available for this

purpose.

 

5)Mark the wall for a 10" x 10" square hole. The center of the square hole should line up with the centerline of the horizontal pipe. Cut and frame the 10 inch square hole in the exterior wall where the vent will be terminated. If the wall being penetrated is constructedofnon-combustiblematerial,i.e. masonry block or concrete, a 7"(178mm) diameter (7-1/2"(191mm) dia. for fl ex) hole is acceptable.

Riser Vent

Termination

Min. 6-1/4"*

(159mm)

connect the venting system to the appliance

fl ue outlet. A twist-lock appliance adaptor

is an available option that must be used in

conjunction with the Simpson Dura-Vent

Direct Vent GS system.

3) Putabeadofsiliconeinsidetheoutersection

of the adapter and a bead of Fireplace Mate

on the inner collar. Slip the adapter over the

existinginnerandouterfluecollarandfasten

to the outer collar only with the 3 supplied

screws (drilling pilot holes will make this

easier). Level the fi replace and fasten it to

the framing using nails or screws through

the nailing strips.

4) Assemble the desired combination of pipe

and elbows to the appliance adaptor and

twist-lock for a solid connection.

Note:

a) Twist-lockprocedure:Fourindentations,

located on the female ends of pipes and

fi ttings, are designed to slide straight

onto the male ends of adjacent pipes

and fi ttings, by orienting the four pipe

indentations so they match and slide

in to the four entry slots on the male

Note:

a)The horizontal run of vent must be level, or have a 1/4 inch rise for every 1 foot of run towards the termination. Never allow the vent to run downward. This could cause high temperatures and may present the possibility of a fi re.

b)The location of the horizontal vent terminationonanexteriorwallmustmeet all local and national building codes, and must not be blocked or obstructed. See "Exterior Vent Terminal Locations" Section.

c)Snorkel Terminations:

For installations requiring a vertical rise on the exterior of the building, 14-inch and 36-inch tall Snorkel Terminations and the Riser Vent as shown in Dia. 2 & 2a are available. Follow the same installation procedures as used for standard Horizontal Termination. NEVER install the snorkel upside down.

Below Grade Snorkel Installation If the Snorkel Termination must be installed below grade, i.e. basement application, proper drainage must be providedtopreventwaterfromentering the Snorkel Termination. Refer to Dura-Vent Installation instructions for details. Do not attempt to enclose the Snorkel within the wall, or any other type of enclosure.

6)The arrow on the vent cap should be pointing up. Insure that the 1-1/2" clearances to combustible materials are maintained (Dia. 3). Install the termination cap. AstroCapTM or Dura-Vent Horizontal Termination Cap may be used.

ends, Dia. 1. Push the pipe sections

completely

together, then twist-lock

one section

clockwise approximately

one-quarter turn, until the two sections

are fully locked. The female locking lugs

will not be visible from the outside, on

the Black Pipe or fi ttings. They may be

located by examining the inside of the

female ends.

 

Diagram 1

Note: Apply sealant "Mill-Pac" to inner pipe and high temperature silicone sealant to outer pipe on every twist-

lock joint.

Dura-Vent

Snorkel

Min. 12"*

(305mm)

Diagram 2

*As specifi ed in CGA B149 Installation Code. Local codes or regulations may require different clearances.

Diagram 3

The four wood screws provided should be replaced with appropriate fasteners for stucco, brick, concrete, or other types of sidings.

Note: If installing termination on a siding covered wall, a vinyl siding standoff or furring strips must be used to ensure that the termination is not recessed into the siding.

7)Beforeconnectingthehorizontalrunofvent pipe to the vent termination, slide the Wall Thimble (Part # 620-926) over the vent pipe.

24

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace

Image 24
Contents P33-4 Zero Clearance Information for MOBILE/MANUFACTURED Homes After First Sale To the New OwnerTable of Contents Safety Label Safety LabelRequirements MA Code CO DetectorInstallation General Safety InformationImportant Message Before YOU StartInstallation Checklist Unit DimensionsLocating Your Fireplace Duct System OptionClearances Mantel LEG ClearancesFraming and Finishing Vertical Termination or Vertical Rise with HorizontalRear Termination Unit Assembly Prior to Installation Top Standoff AssemblyVenting Introduction Top Facing Support Side Nailing StripsExterior Vent Termination Locations VentHeight Meters Minimum Feet RoofPitchRegency Direct Vent Flex System Horizontal Terminations OnlyAlternate Without any joints or seamsInstallation Procedures For Regency Direct Vent System FlexMinimum and Maximum Vent Clearances Flat Wall Installation Vent LengthThickness inches Required inches Max. WallRigid Pipe Venting Components List SV4LB6Rigid Pipe Venting Arrangements Vertical Terminations Propane & Natural GasInstallation Regency Direct Vent System Flex Horizontal Venting with Two 2 90o Elbows Option + H1Option +H1+H2 Option +H1Horizontal Venting with Three 3 90o Elbows Vertical Venting with Two 2 90o ElbowsOption +V1 +H1 Option +V1Vertical Venting with Three 3 90o Elbows Vertical Termination With CO-LINEAR Flex System Required PartsDescription Alternate Approved CapsVenting Arrangements Vertical Terminations Horizontal Distance FeetUnit Installation with Horizontal Termination Snorkel TerminationsLock joint Unit Installation With Vertical Termination GAS Line InstallationThis allows for small adjustments Pilot Adjustment GAS Pipe Pressure TestingHigh Elevation T. Valve DescriptionFor P33-4/H25-1 Using SIT 820 Nova Gas Valve Conversion KIT# 434-969 from NG to LPGlow on logs Installation of the DC Sparker for the P33-4 Unit Only 250 251Standard Flush Door Optional Flush TrimCutout 5th Grate TabFlush Louvers Double Screen DoorOptional BAY Trim Optional BAY DoorBAY Louvers Flush Louver Top Heat ShieldBay Louver Top Heat Shield Burner ON/OFF Control boxFull Screen Doors Cut-Out Oblong Hole Top Flange BottomCut-Outs Hinge Location Bottom Grill Top GrillRemote Control Wall SwitchThermostat Wire Table Wall ThermostatWiring Diagrams Do not cut the ground terminal off under any circumstancesFor Propane Units and Units Equipped with DC Spark Boxes Installing the Optional FAN Secure the 2 boxes together With one screwOperating Instructions Copy of the Lighting Plate InstructionsLighting Procedure Shutdown ProcedureAeration Adjustment Operating InstructionsMaintenance Normal Operating Sounds MaintenanceLOG Replacement GAS AppliancesFlush Glass Replacement Bay Glass ReplacementThermopile Thermocouple Glass GasketInstalling Valve Diagram 3 Lift out Valve Tray AssemblyRemoving Valve Shut off the gas supplyParts List Main AssemblyDescription Parts List Burner & LOG Assembly Part DescriptionFlush Front & Louvers Regency Logo Plate Not available as a replacement part BAY Front & LouversRegency P33-4 Zero Clearance Direct Vent Gas Fireplace Warranty Warranty Limited LifetimeInstaller Please complete the following information

P33-NG4 specifications

The Regency P33-NG4 is a notable offering in the realm of modern communication technology, making waves with its innovative design and robust set of features. This advanced radio has been engineered to meet the demands of both professional users and casual enthusiasts. Its emphasis on reliability, durability, and user-friendly operations positions the P33-NG4 as a leading choice for users in various settings, from emergency services to outdoor adventures.

One of the standout features of the Regency P33-NG4 is its superior audio clarity. It is equipped with advanced noise-canceling technologies that ensure clear communication even in loud environments. Whether you are navigating through bustling city streets or communicating in a remote area, users can expect crisp and intelligible sound. Additionally, the P33-NG4 boasts an impressive range, allowing for seamless communication over long distances, which is essential for coordination during events or emergency situations.

The device supports both analog and digital modes, making it versatile for a range of applications. This feature enables the P33-NG4 to connect easily with other devices, enhancing interoperability in diverse communication scenarios. Its digital capabilities include advanced encryption for secure transmissions, making it a reliable tool for sensitive communications in professional environments.

Another highlight of the P33-NG4 is its rugged construction. Designed to withstand harsh conditions, it is dustproof, waterproof, and impact-resistant. This resilience is crucial for users in demanding fields, ensuring that the device will perform reliably in adverse weather conditions or challenging terrains.

Battery life is another critical characteristic of the P33-NG4. It comes equipped with a high-capacity battery that provides extended usage between charges. This ensures that users remain connected for longer periods, particularly in fieldwork situations where charging options may be limited.

Ease of use is a principle that underlies the design of the Regency P33-NG4. The interface is intuitive, featuring clear displays and tactile buttons for intuitive navigation. Users can quickly access critical functions without extensive training, making it suitable for both seasoned professionals and newcomers to radio communications.

In summary, the Regency P33-NG4 blends innovative technology with practical features, making it a standout choice for a wide array of users. With its clear audio, robust build, versatile communication modes, and user-friendly design, it demonstrates a commitment to quality and performance that is crucial in today’s fast-paced communication environment. Whether for safety, connectivity, or team coordination, the P33-NG4 rises to the occasion.