Regency P33-NG4 Wiring Diagrams, Do not cut the ground terminal off under any circumstances

Page 37

INSTALLATION

WIRING DIAGRAMS

This heater does not require a 120VA.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat will continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation.

(Do not cut the ground terminal off under any circumstances.)

NOTE: Even if the fan is not purchased with the unit, it is still a good idea to bring power to the receptacle box (provided with the unit) in case the fan is installed at a later date.

For NATURAL GAS Units and Units NOT Equipped with DC Spark Boxes

 

 

Lockwasher

Thermopile

 

 

Thermocouple

 

 

 

 

 

 

 

 

 

Star washer

#8 Ground Lug

GasPilot

Electrode

 

 

Ground

 

 

 

 

Fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(mobile home

 

 

 

 

 

 

 

 

 

 

 

 

approved)

 

Neutral

 

 

 

 

 

 

 

 

 

 

 

Live

 

Green

 

 

 

 

 

 

 

 

 

 

 

 

120V AC

 

Ground

 

 

 

 

 

 

 

 

 

 

 

 

60 Hz

 

 

ON

OFF

 

 

 

 

 

 

 

 

Pilot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Black

Red

Red

 

 

 

Assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nut

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan

 

 

 

 

 

 

 

Rotary Speed

 

 

 

Minimum Convection

 

 

 

 

 

 

 

 

 

 

Control

 

 

 

Air Temp. Switch

 

ground wire

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Piezo

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ignitor

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner

ON

White

(To THTP)

 

 

 

 

 

 

Brown

O

 

 

 

 

Gas

OFF

 

 

 

 

 

 

 

 

White

L

OFF

 

P

 

 

Red

 

 

 

 

 

 

 

IH

 

 

 

 

 

 

 

 

 

 

 

 

 

I

 

 

(To TH)

 

 

 

 

 

 

 

NO

T

OL

 

In

Thermostat

 

 

 

 

 

 

 

 

 

 

Black

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To Thermocouple IN

"S.I.T" Valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T-Stat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

OFF

 

 

Regency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote Receiver

Remote Transmitter

 

 

 

 

 

 

 

 

 

 

or Thermostat

 

 

 

 

 

 

 

 

 

 

 

(Optional)

 

 

 

 

 

 

 

 

 

 

(Millivolt) (Optional)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace

37

Image 37
Contents P33-4 Zero Clearance To the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Safety Label Safety LabelMA Code CO Detector RequirementsGeneral Safety Information InstallationImportant Message Before YOU StartUnit Dimensions Installation ChecklistLocating Your Fireplace Duct System OptionMantel LEG Clearances ClearancesVertical Termination or Vertical Rise with Horizontal Framing and FinishingRear Termination Top Standoff Assembly Unit Assembly Prior to InstallationVenting Introduction Top Facing Support Side Nailing StripsVentHeight Meters Minimum Feet RoofPitch Exterior Vent Termination LocationsHorizontal Terminations Only Regency Direct Vent Flex SystemAlternate Without any joints or seamsFor Regency Direct Vent System Flex Installation ProceduresMinimum and Maximum Vent Clearances Vent Length Flat Wall InstallationThickness inches Required inches Max. WallSV4LB6 Rigid Pipe Venting Components ListVertical Terminations Propane & Natural Gas Rigid Pipe Venting ArrangementsInstallation Regency Direct Vent System Flex Option + H1 Horizontal Venting with Two 2 90o ElbowsOption +H1+H2 Option +H1Vertical Venting with Two 2 90o Elbows Horizontal Venting with Three 3 90o ElbowsOption +V1 +H1 Option +V1Vertical Venting with Three 3 90o Elbows Required Parts Vertical Termination With CO-LINEAR Flex SystemDescription Alternate Approved CapsHorizontal Distance Feet Venting Arrangements Vertical TerminationsSnorkel Terminations Unit Installation with Horizontal TerminationLock joint GAS Line Installation Unit Installation With Vertical TerminationThis allows for small adjustments GAS Pipe Pressure Testing Pilot AdjustmentHigh Elevation T. Valve DescriptionConversion KIT# 434-969 from NG to LP For P33-4/H25-1 Using SIT 820 Nova Gas ValveGlow on logs Installation of the DC Sparker for the P33-4 Unit Only 251 250Optional Flush Trim Standard Flush DoorCutout 5th Grate TabDouble Screen Door Flush LouversOptional BAY Trim Optional BAY DoorFlush Louver Top Heat Shield BAY LouversBay Louver Top Heat Shield Burner ON/OFF Control boxCut-Out Oblong Hole Top Flange Bottom Full Screen DoorsCut-Outs Top Grill Hinge Location Bottom GrillWall Switch Remote ControlThermostat Wire Table Wall ThermostatDo not cut the ground terminal off under any circumstances Wiring DiagramsFor Propane Units and Units Equipped with DC Spark Boxes Secure the 2 boxes together With one screw Installing the Optional FANCopy of the Lighting Plate Instructions Operating InstructionsShutdown Procedure Lighting ProcedureAeration Adjustment Operating InstructionsNormal Operating Sounds Maintenance MaintenanceLOG Replacement GAS AppliancesBay Glass Replacement Flush Glass ReplacementThermopile Thermocouple Glass GasketDiagram 3 Lift out Valve Tray Assembly Installing ValveRemoving Valve Shut off the gas supplyMain Assembly Parts ListDescription Parts List Part Description Burner & LOG AssemblyFlush Front & Louvers BAY Front & Louvers Regency Logo Plate Not available as a replacement partRegency P33-4 Zero Clearance Direct Vent Gas Fireplace Warranty Limited Lifetime WarrantyInstaller Please complete the following information

P33-NG4 specifications

The Regency P33-NG4 is a notable offering in the realm of modern communication technology, making waves with its innovative design and robust set of features. This advanced radio has been engineered to meet the demands of both professional users and casual enthusiasts. Its emphasis on reliability, durability, and user-friendly operations positions the P33-NG4 as a leading choice for users in various settings, from emergency services to outdoor adventures.

One of the standout features of the Regency P33-NG4 is its superior audio clarity. It is equipped with advanced noise-canceling technologies that ensure clear communication even in loud environments. Whether you are navigating through bustling city streets or communicating in a remote area, users can expect crisp and intelligible sound. Additionally, the P33-NG4 boasts an impressive range, allowing for seamless communication over long distances, which is essential for coordination during events or emergency situations.

The device supports both analog and digital modes, making it versatile for a range of applications. This feature enables the P33-NG4 to connect easily with other devices, enhancing interoperability in diverse communication scenarios. Its digital capabilities include advanced encryption for secure transmissions, making it a reliable tool for sensitive communications in professional environments.

Another highlight of the P33-NG4 is its rugged construction. Designed to withstand harsh conditions, it is dustproof, waterproof, and impact-resistant. This resilience is crucial for users in demanding fields, ensuring that the device will perform reliably in adverse weather conditions or challenging terrains.

Battery life is another critical characteristic of the P33-NG4. It comes equipped with a high-capacity battery that provides extended usage between charges. This ensures that users remain connected for longer periods, particularly in fieldwork situations where charging options may be limited.

Ease of use is a principle that underlies the design of the Regency P33-NG4. The interface is intuitive, featuring clear displays and tactile buttons for intuitive navigation. Users can quickly access critical functions without extensive training, making it suitable for both seasoned professionals and newcomers to radio communications.

In summary, the Regency P33-NG4 blends innovative technology with practical features, making it a standout choice for a wide array of users. With its clear audio, robust build, versatile communication modes, and user-friendly design, it demonstrates a commitment to quality and performance that is crucial in today’s fast-paced communication environment. Whether for safety, connectivity, or team coordination, the P33-NG4 rises to the occasion.