Regency P33-NG4 Installation, Important Message, Before YOU Start, General Safety Information

Page 6

INSTALLATION

IMPORTANT MESSAGE

SAVE THESE

INSTRUCTIONS

The P33-NG4 or P33-LP4 Direct Vent Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this fi replace is installed in compliance with manufacturer's instructions and all applicable

codes.

BEFORE YOU START

Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:

INSTALLATION AND REPAIR SHOULD BE DONE BY A QUALIFIED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY B Y A P R O F E S S I O N A L SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC. IT IS IMPERATIVE THAT CONTROL COMPARTMENTS, BURNERS AND CIRCULATING A I R PA S S A G E WAY S O F THE APPLIANCE BE KEPT CLEAN.

DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE.

CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPECIALLY THE FIREPLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISEDWHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

C L O T H I N G O R O T H E R FLAMMABLEMATERIALSHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.

GENERAL SAFETY

INFORMATION

1)Theapplianceinstallationmustconformwith local codes or, in the absence of local codes, with the current Canadian or National Gas Codes, CAN1-B149 or ANSI Z223.1 Installation Codes.

2)The appliance when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code.

3)See general construction and assembly instructions. The appliance and vent should be enclosed.

4)This appliance must be connected to the specifi ed vent and termination cap to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is fi tted as per Venting instructions.

5)Inspect the venting system annually for blockage and any signs of deterioration.

6)Venting terminals shall not be recessed into a wall or siding.

7)Any safety glass removed for servicing must be replaced prior to operating the appliance.

8)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fi replace.

9)Wearglovesandsafetyglassesforprotection while doing required maintenance.

10)Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination.

11)Under no circumstances should this appliancebemodified.Partsthathavetobe removed for servicing should be replaced prior to operating this appliance.

12)Installationandanyrepairstothisappliance should be done by a qualifi ed service person. A professional service person should be called to inspect this appliance annually. Make it a practice to have all of your gas appliances checked annually.

13)Do not slam shut or strike the glass door.

14)Under no circumstances should any solid fuels (wood, paper, cardboard, coal, etc.) be used in this appliance.

15)The appliance area must be kept clear and free of combustible materials, (gases and other fl ammable vapours and liquids).

Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

MANUFACTURED

MOBILE HOME

ADDITIONAL

REQUIREMENTS

1)Ensure that structural members are not cut or weakened during installation.

2)Ensure proper grounding using the #8 ground lug provided. Refer to "Wiring Diagram" Section.

6

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace

Image 6
Contents P33-4 Zero Clearance Information for MOBILE/MANUFACTURED Homes After First Sale To the New OwnerTable of Contents Safety Label Safety LabelRequirements MA Code CO DetectorImportant Message InstallationGeneral Safety Information Before YOU StartLocating Your Fireplace Installation ChecklistUnit Dimensions Duct System OptionClearances Mantel LEG ClearancesFraming and Finishing Vertical Termination or Vertical Rise with HorizontalRear Termination Venting Introduction Unit Assembly Prior to InstallationTop Standoff Assembly Top Facing Support Side Nailing StripsExterior Vent Termination Locations VentHeight Meters Minimum Feet RoofPitchAlternate Regency Direct Vent Flex SystemHorizontal Terminations Only Without any joints or seamsInstallation Procedures For Regency Direct Vent System FlexMinimum and Maximum Vent Clearances Thickness inches Required inches Flat Wall InstallationVent Length Max. WallRigid Pipe Venting Components List SV4LB6Rigid Pipe Venting Arrangements Vertical Terminations Propane & Natural GasInstallation Regency Direct Vent System Flex Option +H1+H2 Horizontal Venting with Two 2 90o ElbowsOption + H1 Option +H1Option +V1 +H1 Horizontal Venting with Three 3 90o ElbowsVertical Venting with Two 2 90o Elbows Option +V1Vertical Venting with Three 3 90o Elbows Description Vertical Termination With CO-LINEAR Flex SystemRequired Parts Alternate Approved CapsVenting Arrangements Vertical Terminations Horizontal Distance FeetUnit Installation with Horizontal Termination Snorkel TerminationsLock joint Unit Installation With Vertical Termination GAS Line InstallationThis allows for small adjustments High Elevation Pilot AdjustmentGAS Pipe Pressure Testing T. Valve DescriptionFor P33-4/H25-1 Using SIT 820 Nova Gas Valve Conversion KIT# 434-969 from NG to LPGlow on logs Installation of the DC Sparker for the P33-4 Unit Only 250 251Cutout Standard Flush DoorOptional Flush Trim 5th Grate TabOptional BAY Trim Flush LouversDouble Screen Door Optional BAY DoorBay Louver Top Heat Shield BAY LouversFlush Louver Top Heat Shield Burner ON/OFF Control boxFull Screen Doors Cut-Out Oblong Hole Top Flange BottomCut-Outs Hinge Location Bottom Grill Top GrillThermostat Wire Table Remote ControlWall Switch Wall ThermostatWiring Diagrams Do not cut the ground terminal off under any circumstancesFor Propane Units and Units Equipped with DC Spark Boxes Installing the Optional FAN Secure the 2 boxes together With one screwOperating Instructions Copy of the Lighting Plate InstructionsAeration Adjustment Lighting ProcedureShutdown Procedure Operating InstructionsLOG Replacement MaintenanceNormal Operating Sounds Maintenance GAS AppliancesThermopile Thermocouple Flush Glass ReplacementBay Glass Replacement Glass GasketRemoving Valve Installing ValveDiagram 3 Lift out Valve Tray Assembly Shut off the gas supplyParts List Main AssemblyDescription Parts List Burner & LOG Assembly Part DescriptionFlush Front & Louvers Regency Logo Plate Not available as a replacement part BAY Front & LouversRegency P33-4 Zero Clearance Direct Vent Gas Fireplace Warranty Warranty Limited LifetimeInstaller Please complete the following information

P33-NG4 specifications

The Regency P33-NG4 is a notable offering in the realm of modern communication technology, making waves with its innovative design and robust set of features. This advanced radio has been engineered to meet the demands of both professional users and casual enthusiasts. Its emphasis on reliability, durability, and user-friendly operations positions the P33-NG4 as a leading choice for users in various settings, from emergency services to outdoor adventures.

One of the standout features of the Regency P33-NG4 is its superior audio clarity. It is equipped with advanced noise-canceling technologies that ensure clear communication even in loud environments. Whether you are navigating through bustling city streets or communicating in a remote area, users can expect crisp and intelligible sound. Additionally, the P33-NG4 boasts an impressive range, allowing for seamless communication over long distances, which is essential for coordination during events or emergency situations.

The device supports both analog and digital modes, making it versatile for a range of applications. This feature enables the P33-NG4 to connect easily with other devices, enhancing interoperability in diverse communication scenarios. Its digital capabilities include advanced encryption for secure transmissions, making it a reliable tool for sensitive communications in professional environments.

Another highlight of the P33-NG4 is its rugged construction. Designed to withstand harsh conditions, it is dustproof, waterproof, and impact-resistant. This resilience is crucial for users in demanding fields, ensuring that the device will perform reliably in adverse weather conditions or challenging terrains.

Battery life is another critical characteristic of the P33-NG4. It comes equipped with a high-capacity battery that provides extended usage between charges. This ensures that users remain connected for longer periods, particularly in fieldwork situations where charging options may be limited.

Ease of use is a principle that underlies the design of the Regency P33-NG4. The interface is intuitive, featuring clear displays and tactile buttons for intuitive navigation. Users can quickly access critical functions without extensive training, making it suitable for both seasoned professionals and newcomers to radio communications.

In summary, the Regency P33-NG4 blends innovative technology with practical features, making it a standout choice for a wide array of users. With its clear audio, robust build, versatile communication modes, and user-friendly design, it demonstrates a commitment to quality and performance that is crucial in today’s fast-paced communication environment. Whether for safety, connectivity, or team coordination, the P33-NG4 rises to the occasion.