Regency P33-NG4 Normal Operating Sounds Maintenance, GAS Appliances, Brass Louvers Trim

Page 42

MAINTENANCE

NORMAL OPERATING

SOUNDS OF

MAINTENANCE

GENERAL VENT

INSTRUCTIONS

MAINTENANCE

GAS APPLIANCES

It is possible that you will hear some sounds from your gas appliance.This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance. Listed below are some examples.All are normal operatingsoundsandshouldnotbeconsidered as defects in your appliance.

Blower:

Regency® gas appliances use high tech blowers to push heated air farther into the room. It is not unusual for the fan to make a "whirring" sound when ON. This sound will increase or decrease in volume depending on the speed setting of your fan speed control.

Burner Tray:

The burner tray is positioned directly under the burnertube(s)andlogsandismadeofadifferent gauge material from the rest of the fi rebox and body.Therefore, the varying thicknesses of steel will expand and contract at slightly different rates which can cause "ticking" and "cracking" sounds. You should also be aware that as there are temperature changes within the unit these sounds will likely re-occur. Again, this is normal for steel fi reboxes.

Blower Thermodisc:

When this thermally activated switch turns ON it will create a small "clicking" sound. This is the switch contacts closing and is normal.

Pilot Flame:

While the pilot fl ame is on it can make a very slight "whisper" sound.

Gas Control Valve:

As the gas control valve turns ON and OFF, a dull clicking sound may be audible, this is normal operation of a gas regulator or valve.

Unit Body/Firebox:

1)Alwaysturnoffthegasvalvebeforecleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs, use a soft clean paint brush as the logs are fragile and easily damaged.

2)Clean appliance and door with a damp cloth (never when unit is hot). Never use an abrasive cleaner. The glass should be cleaned with a gas fi replace glass cleaner.

The glass should be cleaned when it starts looking cloudy.

3)The heater is fi nished in a heat resistant paint and should only be refinished with heat resistant paint. Regency® uses StoveBright Paint - Metallic Black #6309.

4)Make a periodic check of burner for proper position and condition. Visually check the flame of the burner periodically, making sure the fl ames are steady; not lifting or fl oating. If there is a problem, call a qualifi ed service person.

5)The appliance and venting system must be inspected before use, and at least annually, by a qualifi ed fi eld service person, to ensure that the fl ow of combustion and ventilation air is not obstructed.

Note: Never operate the appliance without the glass properly secured in place.

6)Donotusethisapplianceifanyparthasbeen under water. Immediately call a qualifi ed service technician to inspect the appliance and to replace nay part of the control system and any gas control which has been under water.

7)Verify operation after servicing.

Conduct an inspection of the venting system semi-annually.Recommendedareastoinspect as follows:

1)Check the Venting System for corrosion in areas that are exposed to the elements. These will appear as rust spots or streaks, andinextremecases,holes.Thesecompo- nents should be replaced immediately.

2)Remove the Cap, and shine a fl ashlight down the Vent. Remove any bird nests, or other foreign material.

3)Check for evidences of excessive condensation, such as water droplets forming in the inner liner, and subsequently dripping out the joints, Continuous condensation can cause corrosion of caps, pipe, and fi ttings. It may be caused by having excessive lateral runs, too many elbows, and exterior portions of the system being exposed to cold weather.

4)Inspect joints, to verify that no pipe sections or fi ttings have been disturbed, and consequently loosened. Also check mechanical supports such as Wall Straps, or plumbers' tape for rigidity.

GOLD-PLATED or

BRASS LOUVERS/

TRIM

The 24 carat gold-plated or brass fi nish on the louvers and trim requires little maintenance, and need only be cleaned with a damp cloth. DO NOT use abrasive materials or chemical cleaners, as they may harm the fi nish and void the warranty. Clean any fingerprints off before turning the unit on.

Different types and thicknesses of steel will expand and contract at different rates resulting in some "cracking" and "ticking" sounds will be heard throughout the cycling process.

LOG REPLACEMENT

Theunitshouldneverbeusedwithbrokenlogs. Turn off the gas valve and allow the unit to cool before opening door and carefully remove the logs. (The pilot light generates enough heat to burn someone.) If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagrams under Log Installation.

Note: Improper positioning of logs may create carbon build-up and will severelyaltertheunit'sperformance which is not covered under warranty.

42

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace

Image 42
Contents P33-4 Zero Clearance Information for MOBILE/MANUFACTURED Homes After First Sale To the New OwnerTable of Contents Safety Label Safety LabelRequirements MA Code CO DetectorImportant Message InstallationGeneral Safety Information Before YOU StartLocating Your Fireplace Installation ChecklistUnit Dimensions Duct System OptionClearances Mantel LEG ClearancesFraming and Finishing Vertical Termination or Vertical Rise with HorizontalRear Termination Venting Introduction Unit Assembly Prior to InstallationTop Standoff Assembly Top Facing Support Side Nailing StripsExterior Vent Termination Locations VentHeight Meters Minimum Feet RoofPitchAlternate Regency Direct Vent Flex SystemHorizontal Terminations Only Without any joints or seamsInstallation Procedures For Regency Direct Vent System FlexMinimum and Maximum Vent Clearances Thickness inches Required inches Flat Wall InstallationVent Length Max. WallRigid Pipe Venting Components List SV4LB6Rigid Pipe Venting Arrangements Vertical Terminations Propane & Natural GasInstallation Regency Direct Vent System Flex Option +H1+H2 Horizontal Venting with Two 2 90o ElbowsOption + H1 Option +H1Option +V1 +H1 Horizontal Venting with Three 3 90o ElbowsVertical Venting with Two 2 90o Elbows Option +V1Vertical Venting with Three 3 90o Elbows Description Vertical Termination With CO-LINEAR Flex SystemRequired Parts Alternate Approved CapsVenting Arrangements Vertical Terminations Horizontal Distance FeetUnit Installation with Horizontal Termination Snorkel TerminationsLock joint Unit Installation With Vertical Termination GAS Line InstallationThis allows for small adjustments High Elevation Pilot AdjustmentGAS Pipe Pressure Testing T. Valve DescriptionFor P33-4/H25-1 Using SIT 820 Nova Gas Valve Conversion KIT# 434-969 from NG to LPGlow on logs Installation of the DC Sparker for the P33-4 Unit Only 250 251Cutout Standard Flush DoorOptional Flush Trim 5th Grate TabOptional BAY Trim Flush LouversDouble Screen Door Optional BAY DoorBay Louver Top Heat Shield BAY LouversFlush Louver Top Heat Shield Burner ON/OFF Control boxFull Screen Doors Cut-Out Oblong Hole Top Flange BottomCut-Outs Hinge Location Bottom Grill Top GrillThermostat Wire Table Remote ControlWall Switch Wall ThermostatWiring Diagrams Do not cut the ground terminal off under any circumstancesFor Propane Units and Units Equipped with DC Spark Boxes Installing the Optional FAN Secure the 2 boxes together With one screwOperating Instructions Copy of the Lighting Plate InstructionsAeration Adjustment Lighting ProcedureShutdown Procedure Operating InstructionsLOG Replacement MaintenanceNormal Operating Sounds Maintenance GAS AppliancesThermopile Thermocouple Flush Glass ReplacementBay Glass Replacement Glass GasketRemoving Valve Installing ValveDiagram 3 Lift out Valve Tray Assembly Shut off the gas supplyParts List Main AssemblyDescription Parts List Burner & LOG Assembly Part DescriptionFlush Front & Louvers Regency Logo Plate Not available as a replacement part BAY Front & LouversRegency P33-4 Zero Clearance Direct Vent Gas Fireplace Warranty Warranty Limited LifetimeInstaller Please complete the following information

P33-NG4 specifications

The Regency P33-NG4 is a notable offering in the realm of modern communication technology, making waves with its innovative design and robust set of features. This advanced radio has been engineered to meet the demands of both professional users and casual enthusiasts. Its emphasis on reliability, durability, and user-friendly operations positions the P33-NG4 as a leading choice for users in various settings, from emergency services to outdoor adventures.

One of the standout features of the Regency P33-NG4 is its superior audio clarity. It is equipped with advanced noise-canceling technologies that ensure clear communication even in loud environments. Whether you are navigating through bustling city streets or communicating in a remote area, users can expect crisp and intelligible sound. Additionally, the P33-NG4 boasts an impressive range, allowing for seamless communication over long distances, which is essential for coordination during events or emergency situations.

The device supports both analog and digital modes, making it versatile for a range of applications. This feature enables the P33-NG4 to connect easily with other devices, enhancing interoperability in diverse communication scenarios. Its digital capabilities include advanced encryption for secure transmissions, making it a reliable tool for sensitive communications in professional environments.

Another highlight of the P33-NG4 is its rugged construction. Designed to withstand harsh conditions, it is dustproof, waterproof, and impact-resistant. This resilience is crucial for users in demanding fields, ensuring that the device will perform reliably in adverse weather conditions or challenging terrains.

Battery life is another critical characteristic of the P33-NG4. It comes equipped with a high-capacity battery that provides extended usage between charges. This ensures that users remain connected for longer periods, particularly in fieldwork situations where charging options may be limited.

Ease of use is a principle that underlies the design of the Regency P33-NG4. The interface is intuitive, featuring clear displays and tactile buttons for intuitive navigation. Users can quickly access critical functions without extensive training, making it suitable for both seasoned professionals and newcomers to radio communications.

In summary, the Regency P33-NG4 blends innovative technology with practical features, making it a standout choice for a wide array of users. With its clear audio, robust build, versatile communication modes, and user-friendly design, it demonstrates a commitment to quality and performance that is crucial in today’s fast-paced communication environment. Whether for safety, connectivity, or team coordination, the P33-NG4 rises to the occasion.