Regency P33-NG4 installation manual Installation Procedures, For Regency Direct Vent System Flex

Page 13

INSTALLATION

INSTALLATION PROCEDURES

for Regency® Direct Vent System (Flex)

1)Locate the unit in the framing, rough in the gas (preferably on the right side of the unit) and the electrical (Junction block is on the left side) on the left. Locate the centerline of the termination and mark wall accordingly. Cut a 10"(254mm) hole in the wall (inside dimension).

Note: To make the installation more aestheticallypleasing,werecommend framing out a square to mount the terminal to.

Note: A 2-1/2" (64mm) horizontal top and 1-1/2" (38mm) horizontal sides & bottom clearance around the liner

*If this is an outside corner, the minimum distance between the vent and the outside corner is 6" (15cm) with AstroCap termination cap or 12" (30cm) with Dura-Vent termination cap. See "F" in the diagram in "Exterior Vent Trmination Locations" Section.

Minimum and Maximum Vent Clearances

must be maintained except that only a 1" (25mm) clearance is needed at the termination end. We recommend framing a 10"(254mm) x 10"(254mm) (inside dimensions) hole to give structural rigidity for mounting the termination.

Note: If installing termination on a siding covered wall, furring strips must be used to ensure that the termination is not recessed into the siding.

2) Levelthefireplaceandfastenittotheframing

using nails or screws through the nailing

strips.

5)Slip the assembled liner and termination assembly through the thimble making sure the termination cap faces up (there are markings on the cap that show which way is up). This will position the termination cap with proper down slope for draining water. Fasten the cap to the outer wall with the 4 supplied screws.

6)Pull the centre 4"(100mm) liner and outer 6-7/8"(175mm) liner out enough to slip over the fl ue collars of the fi replace.

7)Apply Mill Pac over the fi replace inner collar and slip the 4"(100mm) liner down over it and attach with 3 supplied screws.

8)Do the same with the 6-7/8"(175mm) liner.

9)Apply a bead of silicone between the thimble and termination and around the outer edge of the terminal at the wall in order to keep the water out.

IMPORTANT:Donotlocatetermination hood where excessive snow or ice buildup may occur. Be sure to check vent termination area after snow falls, and clear to prevent accidental blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area.

3) Assemble the vent assembly by applying

Mill Pac to the 4"(100mm) inner collar of the

terminationand slippingthe4"(100mm)liner

over it at least 1-3/8" (35mm). Fasten with

the3screws(drillingpilotholeswillmakethis

easier). Apply Mill Pac or high temperature

silicone to the 6-7/8"(175mm) fl ex pipe and

slip it over the 6-7/8" outer collar of the vent

terminal at least 1-3/8"(35mm) and fasten

with the 3 screws.

4) Separate the 2 halves of the wall thimble and

securely fasten the one with the tabs to the

outside wall making sure that the tabs are

on top and bottom. Fasten the other thimble

half to the inside wall. The thimble halves

slip inside each other and can be adjusted

for 2 x 4 or 2 x 6 walls. The liners must slip

over the collars a minimum of 1-3/8".

 

 

2” x 4” or 2” x 6”

4" (102mm)

 

(21mm x 102mm

 

or 21mm x 152mm)

dia. flue pipe

 

 

Termination Cap

with spring spacer

 

 

 

 

 

 

 

 

 

Screws

(3 per

connection)

6-7/8"

Screws

(175mm)

(4 per connection)

dia. air intake

 

Wall Thimble 2 pieces

 

(10" (254mm) Outer Diameter)

 

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace

13

Image 13
Contents P33-4 Zero Clearance To the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Safety Label Safety LabelMA Code CO Detector RequirementsGeneral Safety Information InstallationImportant Message Before YOU StartUnit Dimensions Installation ChecklistLocating Your Fireplace Duct System OptionMantel LEG Clearances ClearancesVertical Termination or Vertical Rise with Horizontal Framing and FinishingRear Termination Top Standoff Assembly Unit Assembly Prior to InstallationVenting Introduction Top Facing Support Side Nailing StripsVentHeight Meters Minimum Feet RoofPitch Exterior Vent Termination LocationsHorizontal Terminations Only Regency Direct Vent Flex SystemAlternate Without any joints or seamsFor Regency Direct Vent System Flex Installation ProceduresMinimum and Maximum Vent Clearances Vent Length Flat Wall InstallationThickness inches Required inches Max. WallSV4LB6 Rigid Pipe Venting Components ListVertical Terminations Propane & Natural Gas Rigid Pipe Venting ArrangementsInstallation Regency Direct Vent System Flex Option + H1 Horizontal Venting with Two 2 90o ElbowsOption +H1+H2 Option +H1Vertical Venting with Two 2 90o Elbows Horizontal Venting with Three 3 90o ElbowsOption +V1 +H1 Option +V1Vertical Venting with Three 3 90o Elbows Required Parts Vertical Termination With CO-LINEAR Flex SystemDescription Alternate Approved CapsHorizontal Distance Feet Venting Arrangements Vertical TerminationsSnorkel Terminations Unit Installation with Horizontal TerminationLock joint GAS Line Installation Unit Installation With Vertical TerminationThis allows for small adjustments GAS Pipe Pressure Testing Pilot AdjustmentHigh Elevation T. Valve DescriptionConversion KIT# 434-969 from NG to LP For P33-4/H25-1 Using SIT 820 Nova Gas ValveGlow on logs Installation of the DC Sparker for the P33-4 Unit Only 251 250Optional Flush Trim Standard Flush DoorCutout 5th Grate TabDouble Screen Door Flush LouversOptional BAY Trim Optional BAY DoorFlush Louver Top Heat Shield BAY LouversBay Louver Top Heat Shield Burner ON/OFF Control boxCut-Out Oblong Hole Top Flange Bottom Full Screen DoorsCut-Outs Top Grill Hinge Location Bottom GrillWall Switch Remote ControlThermostat Wire Table Wall ThermostatDo not cut the ground terminal off under any circumstances Wiring DiagramsFor Propane Units and Units Equipped with DC Spark Boxes Secure the 2 boxes together With one screw Installing the Optional FANCopy of the Lighting Plate Instructions Operating InstructionsShutdown Procedure Lighting ProcedureAeration Adjustment Operating InstructionsNormal Operating Sounds Maintenance MaintenanceLOG Replacement GAS AppliancesBay Glass Replacement Flush Glass ReplacementThermopile Thermocouple Glass GasketDiagram 3 Lift out Valve Tray Assembly Installing ValveRemoving Valve Shut off the gas supplyMain Assembly Parts ListDescription Parts List Part Description Burner & LOG AssemblyFlush Front & Louvers BAY Front & Louvers Regency Logo Plate Not available as a replacement partRegency P33-4 Zero Clearance Direct Vent Gas Fireplace Warranty Limited Lifetime WarrantyInstaller Please complete the following information

P33-NG4 specifications

The Regency P33-NG4 is a notable offering in the realm of modern communication technology, making waves with its innovative design and robust set of features. This advanced radio has been engineered to meet the demands of both professional users and casual enthusiasts. Its emphasis on reliability, durability, and user-friendly operations positions the P33-NG4 as a leading choice for users in various settings, from emergency services to outdoor adventures.

One of the standout features of the Regency P33-NG4 is its superior audio clarity. It is equipped with advanced noise-canceling technologies that ensure clear communication even in loud environments. Whether you are navigating through bustling city streets or communicating in a remote area, users can expect crisp and intelligible sound. Additionally, the P33-NG4 boasts an impressive range, allowing for seamless communication over long distances, which is essential for coordination during events or emergency situations.

The device supports both analog and digital modes, making it versatile for a range of applications. This feature enables the P33-NG4 to connect easily with other devices, enhancing interoperability in diverse communication scenarios. Its digital capabilities include advanced encryption for secure transmissions, making it a reliable tool for sensitive communications in professional environments.

Another highlight of the P33-NG4 is its rugged construction. Designed to withstand harsh conditions, it is dustproof, waterproof, and impact-resistant. This resilience is crucial for users in demanding fields, ensuring that the device will perform reliably in adverse weather conditions or challenging terrains.

Battery life is another critical characteristic of the P33-NG4. It comes equipped with a high-capacity battery that provides extended usage between charges. This ensures that users remain connected for longer periods, particularly in fieldwork situations where charging options may be limited.

Ease of use is a principle that underlies the design of the Regency P33-NG4. The interface is intuitive, featuring clear displays and tactile buttons for intuitive navigation. Users can quickly access critical functions without extensive training, making it suitable for both seasoned professionals and newcomers to radio communications.

In summary, the Regency P33-NG4 blends innovative technology with practical features, making it a standout choice for a wide array of users. With its clear audio, robust build, versatile communication modes, and user-friendly design, it demonstrates a commitment to quality and performance that is crucial in today’s fast-paced communication environment. Whether for safety, connectivity, or team coordination, the P33-NG4 rises to the occasion.