Regency P33-NG4 Standard Flush Door, Optional Flush Trim, Cutout, 5th Grate Tab

Page 31

INSTALLATION

250

253

254

6)Place the bottom left front edge of Log 251 against the left edge of the burner tray and

rest the log on the cutout on Log 253.

8) Pull off ember size pieces of rockwool and gently place them on the front of the burner tray in the places shown in the photo below. Do not compress the rockwool, leave it loose.

Diagram 1

250

251

253

254

Cutout

7)Position Log 252 across the cutouts in Logs 254 and 253. The notch in the bottom right end fi tting against the 5th grate tab.

252

253

254

 

5th Grate Tab

 

 

250

251

 

252

253

254

 

Place rockwool in these 2 locations

on the burner tray.

9)Test fi re to ensure proper light off (make sure fl ame fl ows smoothly from one end of burner to the other). If there is any fl ame hesitation, check that area for any blockage of the burner ports.

10)Install fl ush glass and bay glass (if used) as per instructions in this manual.

STANDARD FLUSH

DOOR

The standard flush door comes with a black frame. To install the frame, simply hook the top door fl ange onto the top of the unit and swing the door towards the unit, diagram 1. Be careful that the glass gasket does not roll up; there must be a gap between the gasket and the door lip to ensure that the door sits securely on the unit. See Diagram 2.

Diagram 2

Use the hook to pull the spring out until you can put the hook into the slot on the bottom door bracket. Repeat for 2nd spring. See diagram 3.

Diagram 3

To remove the fl ush door, reverse the above steps.

OPTIONAL FLUSH

TRIM

Attach the round magnets to the back of the top trim piece and to the bottom trim piece, then attach trim to the top and bottom of Flush door.

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace

31

Image 31
Contents P33-4 Zero Clearance To the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Safety Label Safety LabelMA Code CO Detector RequirementsBefore YOU Start InstallationGeneral Safety Information Important MessageDuct System Option Installation ChecklistUnit Dimensions Locating Your FireplaceMantel LEG Clearances ClearancesVertical Termination or Vertical Rise with Horizontal Framing and FinishingRear Termination Top Facing Support Side Nailing Strips Unit Assembly Prior to InstallationTop Standoff Assembly Venting IntroductionVentHeight Meters Minimum Feet RoofPitch Exterior Vent Termination LocationsWithout any joints or seams Regency Direct Vent Flex SystemHorizontal Terminations Only AlternateFor Regency Direct Vent System Flex Installation ProceduresMinimum and Maximum Vent Clearances Max. Wall Flat Wall InstallationVent Length Thickness inches Required inchesSV4LB6 Rigid Pipe Venting Components ListVertical Terminations Propane & Natural Gas Rigid Pipe Venting ArrangementsInstallation Regency Direct Vent System Flex Option +H1 Horizontal Venting with Two 2 90o ElbowsOption + H1 Option +H1+H2Option +V1 Horizontal Venting with Three 3 90o ElbowsVertical Venting with Two 2 90o Elbows Option +V1 +H1Vertical Venting with Three 3 90o Elbows Alternate Approved Caps Vertical Termination With CO-LINEAR Flex SystemRequired Parts DescriptionHorizontal Distance Feet Venting Arrangements Vertical TerminationsSnorkel Terminations Unit Installation with Horizontal TerminationLock joint GAS Line Installation Unit Installation With Vertical TerminationThis allows for small adjustments T. Valve Description Pilot AdjustmentGAS Pipe Pressure Testing High ElevationConversion KIT# 434-969 from NG to LP For P33-4/H25-1 Using SIT 820 Nova Gas ValveGlow on logs Installation of the DC Sparker for the P33-4 Unit Only 251 2505th Grate Tab Standard Flush DoorOptional Flush Trim CutoutOptional BAY Door Flush LouversDouble Screen Door Optional BAY TrimBurner ON/OFF Control box BAY LouversFlush Louver Top Heat Shield Bay Louver Top Heat ShieldCut-Out Oblong Hole Top Flange Bottom Full Screen DoorsCut-Outs Top Grill Hinge Location Bottom GrillWall Thermostat Remote ControlWall Switch Thermostat Wire TableDo not cut the ground terminal off under any circumstances Wiring DiagramsFor Propane Units and Units Equipped with DC Spark Boxes Secure the 2 boxes together With one screw Installing the Optional FANCopy of the Lighting Plate Instructions Operating InstructionsOperating Instructions Lighting ProcedureShutdown Procedure Aeration AdjustmentGAS Appliances MaintenanceNormal Operating Sounds Maintenance LOG ReplacementGlass Gasket Flush Glass ReplacementBay Glass Replacement Thermopile ThermocoupleShut off the gas supply Installing ValveDiagram 3 Lift out Valve Tray Assembly Removing ValveMain Assembly Parts ListDescription Parts List Part Description Burner & LOG AssemblyFlush Front & Louvers BAY Front & Louvers Regency Logo Plate Not available as a replacement partRegency P33-4 Zero Clearance Direct Vent Gas Fireplace Warranty Limited Lifetime WarrantyInstaller Please complete the following information

P33-NG4 specifications

The Regency P33-NG4 is a notable offering in the realm of modern communication technology, making waves with its innovative design and robust set of features. This advanced radio has been engineered to meet the demands of both professional users and casual enthusiasts. Its emphasis on reliability, durability, and user-friendly operations positions the P33-NG4 as a leading choice for users in various settings, from emergency services to outdoor adventures.

One of the standout features of the Regency P33-NG4 is its superior audio clarity. It is equipped with advanced noise-canceling technologies that ensure clear communication even in loud environments. Whether you are navigating through bustling city streets or communicating in a remote area, users can expect crisp and intelligible sound. Additionally, the P33-NG4 boasts an impressive range, allowing for seamless communication over long distances, which is essential for coordination during events or emergency situations.

The device supports both analog and digital modes, making it versatile for a range of applications. This feature enables the P33-NG4 to connect easily with other devices, enhancing interoperability in diverse communication scenarios. Its digital capabilities include advanced encryption for secure transmissions, making it a reliable tool for sensitive communications in professional environments.

Another highlight of the P33-NG4 is its rugged construction. Designed to withstand harsh conditions, it is dustproof, waterproof, and impact-resistant. This resilience is crucial for users in demanding fields, ensuring that the device will perform reliably in adverse weather conditions or challenging terrains.

Battery life is another critical characteristic of the P33-NG4. It comes equipped with a high-capacity battery that provides extended usage between charges. This ensures that users remain connected for longer periods, particularly in fieldwork situations where charging options may be limited.

Ease of use is a principle that underlies the design of the Regency P33-NG4. The interface is intuitive, featuring clear displays and tactile buttons for intuitive navigation. Users can quickly access critical functions without extensive training, making it suitable for both seasoned professionals and newcomers to radio communications.

In summary, the Regency P33-NG4 blends innovative technology with practical features, making it a standout choice for a wide array of users. With its clear audio, robust build, versatile communication modes, and user-friendly design, it demonstrates a commitment to quality and performance that is crucial in today’s fast-paced communication environment. Whether for safety, connectivity, or team coordination, the P33-NG4 rises to the occasion.