Regency G36D-LP PROPANE, G36D-NG NATURAL GAS installation manual Vent, Air supply outlet

Page 10

10

Vertical Termination

24"

D

E

V

Inside corner detail

G

V

A

Vertical

Termination

24"

18"

V

EXTERIOR

INSTALLATION

B

V

M

.

C

 

V

Fixed

 

 

Closed

F

V

Openable

 

B

V

Openable

B

Fixed Closed

 

H

V

 

B

N

 

L

VENT

B

B

V

K

A

 

j

 

 

 

A

 

V

A

V

Vent terminal

A

Air supply outlet

 

Area where terminal is not permited

 

 

 

 

UltraGlow G36D Zero Clearance Direct Vent

A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) B= Clearance to window or door that may be opened *(12"/30cm) #(9"/23cm) C= Clearance to permanently closed window *(min. 12"/30cm)

D= Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of (24"/60cm) from the centerline of the terminal (min. 18"/46cm) check with local code.

E= Clearance to unventilated soffit (min. 15"/38cm)

F= Clearance to outside corner: with AstroCap Termination Cap (min. 6"/15cm), with Dura-Vent Termination Cap (14"/36cm)

G= Clearance to inside corner: with AstroCap Termination Cap (min. 6"/15cm), with Dura- Vent Termination Cap (12"/30cm)

H= Not to be installed above a meter/regulator assembly within (3'/90cm) horizontally from the centerline of the regulator.

J= Clearance to service regulator vent outlet *(min. 36"/90cm)

K= Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance *(12"/30cm) #(9"/23cm)

L= Clearance to a mechanical air supply inlet *(min. 72"/1.8m) #3' (91cm) above if with in 10' (3m) horizontally.

M= Clearance above paved sidewalk or a paved driveway located on public property *(min. 84"/2.1m)

N= Clearance under veranda, porch, deck, or balcony *(min. 12"/30cm)

TERMINATION LOCATIONS

Gas Fireplace

Note:

-A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.

-Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.

-If the vent termination is accessible, a certified guard shall be installed.

*As specified in CGA B149 Installation Code. Note: Local codes or regulations may require different clearances.

# In accordance with the current ANSI Z223.1/NFPA 54 ,National Fuel Gas Code.

Image 10
Contents Call the fire department Do not touch any electrical switchFrom a neighbours phone. Follow Unless a certified kit is usedInformation for MOBILE/MANUFACTURED Homes After First Sale To the New OwnerTable of Contents Safety Label Copy of Safety Decal for G36D-NGInstallation Checklist InstallationGeneral Safety Information Save These InstructionsManufactured Mobile Home Additional Requirements Locating Your GAS StoveThis includes Mantel LEG Clearances ClearancesFraming Finishing Combustible Mantels Venting Introduction Unit Assembly Prior to InstallationTop Standoff Assembly Top Facing Support Side Nailing StripsVent Air supply outletVenting Description Simpson Dura-Vent Selkirk Rigid Pipe Venting Components ListDirect VentGS R Direct-Temp TM Horizontal Rigid Pipe Venting SystemsAlternate CapsRigid Pipe Venting Arrangements Horizontal Terminations Ultraglow Direct Vent System FlexInstallation Ridid Pipe Venting Arrangements Vertical Terminations Installation Vertical Termination With CO-LINEAR Flex System Required PartsInstallation Horizontal Installations Snorkel TerminationsVertical Termination Continue to assemble pipe lengthsOffset Chart Installation ProceduresFor UltraGlow Direct Vent System Flex GAS Pipe Pressure Testing Pilot AdjustmentGAS Line Installation High ElevationBurner Orifi ce LOG SET Installation 02-75 02-55 02-52 02-50 02-53 02-51 02-5402-54 02-51 02-55 Flush Louvers Standard Flush DoorOptional Flush Trim Thermostat Wire Table Remote ControlWall Switch Wall ThermostatWiring Diagram Do not cut the ground terminal off under any circumstancesInstalling the Optional FAN To Remove the FanOperating Instructions Normal Operating Sounds of GAS Appliances Maintenance InstructionsCopy of the Lighting Plate Instructions Maintenance Installing Valve Removing ValveParts List G36D Main AssemblyG36D Burner Assembly & LOG SET G36D Flush Front Assembly Conditions WarrantyExclusions Register your UltraGlow online at

G36D-NG NATURAL GAS, G36D-LP PROPANE specifications

The Regency G36D-LP Propane and G36D-NG Natural Gas fireplaces are exemplary models designed to enhance both aesthetic appeal and functional warmth in any home. These innovative units are perfect for individuals looking to add a touch of elegance while enjoying the convenience of modern fireplace technology.

One of the primary features of the G36D series is its impressive heating capability, which can produce up to 34,000 BTUs, making it effective for warming large living spaces. This efficiency is complemented by their design, which allows for rapid heat distribution, ensuring that the warmth is felt throughout the room.

Both models are available in propane and natural gas options, providing flexibility based on user preference or availability. The G36D-LP utilizes propane, making it ideal for homes without a natural gas line, while the G36D-NG is suitable for those connected to a natural gas supply. This adaptability allows homeowners to choose the most economical and convenient fuel source for their needs.

A standout characteristic of the G36D series is its clean, contemporary design. The fireplace features large viewing windows that are bordered by an elegant frame, offering an unobstructed view of the flames. The realistic log set and glowing embers create a visually stunning fire experience that mimics the ambiance of a traditional wood-burning fireplace without the associated maintenance.

The fireplaces are also equipped with state-of-the-art technology, including a reliable electronic ignition system, which ensures easy starts every time while enhancing safety. The G36D series features adjustable flame height settings, allowing users to customize their experience based on preference or room ambiance.

In terms of efficiency, the G36D fireplaces boast an annual fuel utilization efficiency (AFUE) rating that meets modern energy standards. This characteristic not only contributes to environmental sustainability but also results in lower utility costs over time.

Moreover, the G36D series is designed with a user-friendly interface, allowing homeowners to operate their fireplace with ease. With optional remote controls and wall switches available, adjusting the settings has never been more convenient.

The Regency G36D-LP and G36D-NG are perfect for those who seek the charm of a fireplace with the benefits of modern innovation. Their blend of aesthetic appeal, advanced technology, and efficient heating makes them a standout choice for any homeowner looking to enhance their living space.