Regency G36D-NG NATURAL GAS Installation, Save These Instructions, Before YOU Start

Page 5

INSTALLATION

IMPORTANT:

SAVE THESE

INSTRUCTIONS

TheG36D-NGor G36D-LPDirect Vent Fireplace must be installed in accordance with these in- structions. Carefully read all the instructions in this manual fi rst. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation. It is the respon- sibility of the installer to ensure this fi replace is installed in compliance with manufacturer's instructions and all applicable codes.

BEFORE YOU START

Safe installation and operation of this appli- ance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the

INSTALLATIONANDREPAIRSHOULD BE DONE BY A QUALIFIED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PRO- FESSIONAL SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC. IT IS IMPERATIVE THAT CONTROL COMPARTMENTS, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.

DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.

WARNING:FAILURETOINSTALLTHIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE.

CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGHSURFACETEMPERATURES,ES- PECIALLY THE FIREPLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

CLOTHING OR OTHER FLAMMABLE MATERIALSHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.

GENERAL SAFETY

INFORMATION

1)The appliance installation must conform with local codes or, in the absence of local codes, with the current Canadian or National Gas Codes, CAN1-B149 or ANSI Z223.1 Installation Codes.

2)The appliance when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code.

3)See general construction and assembly instructions. The appliance and vent should be enclosed.

4)This appliance must be connected to the specifi ed vent and termination cap to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is fi tted as per Venting instructions.

5)Inspect the venting system annually for blockage and any signs of deterioration.

6)Venting terminals shall not be recessed into a wall or siding.

7)Any safety glass removed for servicing must be replaced prior to operating the appliance.

8)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fi replace.

9)Wear gloves and safety glasses for protec- tion while doing required maintenance.

10)Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination.

11)Under no circumstances should this ap- pliance be modifi ed. Parts that have to be removed for servicing should be replaced prior to operating this appliance.

12)Installation and any repairs to this appliance should be done by a qualifi ed service per- son. A professional service person should be called to inspect this appliance annually. Make it a practice to have all of your gas appliances checked annually.

13)Do not slam shut or strike the glass door.

14)Under no circumstances should any solid fuels (wood, paper, cardboard, coal, etc.) be used in this appliance.

15)The appliance area must be kept clear and free of combustible materials, (gases and other fl ammable vapours and liquids).

Emissions from burning wood or gas could contain chemicals known to the State of Cali- fornia to cause cancer, birth defects or other reproductive harm.

INSTALLATION

CHECKLIST

1)Locate appliance

a)Room location, page 6

b)Clearances to Combustibles, pages 6 -8.

c)Mantle Clearances, page 8

d)Framing & Finishing Requirements, page 7

e)Venting Requirements, pages 10 - 17.

2)Assemble Top Standoffs and Top Facing Support and Side Nailing Strips, page 9. (NOTE: must be done before installing unit into fi replace.)

3)Install vent, pages 20-22.

4)Make gas and electrical connections. Test the pilot. Must be as per diagram. Page 23.

5)Install log set where indicated on page 25 - 27.

6)Install Flush Door Front (Standard) and optional Flush Gold Trim, page 28.

7)Install Louvers page 28.

8)InstalloptionalWallSwitch,RemoteControl, or Wall Thermostat, page 29.

9)Final check.

Before leaving this unit with the customer, the installer must ensure that the appliance is fi r- ing correctly and operation fully explained to customer.

UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace

5

Image 5
Contents From a neighbours phone. Follow Do not touch any electrical switchCall the fire department Unless a certified kit is usedTo the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Copy of Safety Decal for G36D-NG Safety LabelGeneral Safety Information InstallationInstallation Checklist Save These InstructionsThis includes Locating Your GAS StoveManufactured Mobile Home Additional Requirements Framing Finishing ClearancesMantel LEG Clearances Combustible Mantels Top Standoff Assembly Unit Assembly Prior to InstallationVenting Introduction Top Facing Support Side Nailing StripsAir supply outlet VentVenting Direct VentGS R Direct-Temp TM Rigid Pipe Venting Components ListDescription Simpson Dura-Vent Selkirk Alternate Rigid Pipe Venting SystemsHorizontal CapsUltraglow Direct Vent System Flex Rigid Pipe Venting Arrangements Horizontal TerminationsInstallation Ridid Pipe Venting Arrangements Vertical Terminations Installation Required Parts Vertical Termination With CO-LINEAR Flex SystemInstallation Snorkel Terminations Horizontal InstallationsContinue to assemble pipe lengths Vertical TerminationFor UltraGlow Direct Vent System Flex Installation ProceduresOffset Chart GAS Line Installation Pilot AdjustmentGAS Pipe Pressure Testing High ElevationBurner Orifi ce 02-75 02-55 02-52 02-50 02-53 02-51 02-54 LOG SET Installation02-54 02-51 02-55 Optional Flush Trim Standard Flush DoorFlush Louvers Wall Switch Remote ControlThermostat Wire Table Wall ThermostatDo not cut the ground terminal off under any circumstances Wiring DiagramTo Remove the Fan Installing the Optional FANOperating Instructions Copy of the Lighting Plate Instructions Maintenance InstructionsNormal Operating Sounds of GAS Appliances Maintenance Removing Valve Installing ValveG36D Main Assembly Parts ListG36D Burner Assembly & LOG SET G36D Flush Front Assembly Exclusions WarrantyConditions Register your UltraGlow online at

G36D-NG NATURAL GAS, G36D-LP PROPANE specifications

The Regency G36D-LP Propane and G36D-NG Natural Gas fireplaces are exemplary models designed to enhance both aesthetic appeal and functional warmth in any home. These innovative units are perfect for individuals looking to add a touch of elegance while enjoying the convenience of modern fireplace technology.

One of the primary features of the G36D series is its impressive heating capability, which can produce up to 34,000 BTUs, making it effective for warming large living spaces. This efficiency is complemented by their design, which allows for rapid heat distribution, ensuring that the warmth is felt throughout the room.

Both models are available in propane and natural gas options, providing flexibility based on user preference or availability. The G36D-LP utilizes propane, making it ideal for homes without a natural gas line, while the G36D-NG is suitable for those connected to a natural gas supply. This adaptability allows homeowners to choose the most economical and convenient fuel source for their needs.

A standout characteristic of the G36D series is its clean, contemporary design. The fireplace features large viewing windows that are bordered by an elegant frame, offering an unobstructed view of the flames. The realistic log set and glowing embers create a visually stunning fire experience that mimics the ambiance of a traditional wood-burning fireplace without the associated maintenance.

The fireplaces are also equipped with state-of-the-art technology, including a reliable electronic ignition system, which ensures easy starts every time while enhancing safety. The G36D series features adjustable flame height settings, allowing users to customize their experience based on preference or room ambiance.

In terms of efficiency, the G36D fireplaces boast an annual fuel utilization efficiency (AFUE) rating that meets modern energy standards. This characteristic not only contributes to environmental sustainability but also results in lower utility costs over time.

Moreover, the G36D series is designed with a user-friendly interface, allowing homeowners to operate their fireplace with ease. With optional remote controls and wall switches available, adjusting the settings has never been more convenient.

The Regency G36D-LP and G36D-NG are perfect for those who seek the charm of a fireplace with the benefits of modern innovation. Their blend of aesthetic appeal, advanced technology, and efficient heating makes them a standout choice for any homeowner looking to enhance their living space.