Regency G36D-NG NATURAL GAS, G36D-LP PROPANE Mantel LEG Clearances, Framing Finishing

Page 7

INSTALLATION

CLEARANCES

The clearances listed below are Minimum distances unless otherwise stated:

A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions.

Clearance to Combustibles from:

 

Back

0"

(0mm)

Side

0"

(0mm)

Floor

0"

(0mm)

NOTE: The minimum floor clearance must be maintained from the top surface of the carpeting, tile, etc.

Minimum Clearance from Top of Unit to:

Mantel* Minimum 7" (177mm) Ceiling from top of unit. 32" (1016mm)

Side Wall Clearance

 

 

Flush Front

6"

(152mm)

Horizontal Vent Clearances

 

 

Top

2-1/2" (64mm)

Side

1-1/2" (38mm)

Bottom

1-1/2" (38mm)

Vertical Vent Clearances

1-1/4" (32mm)

Alcove Clearances**:

 

 

Max. Depth

36"

(914mm)

Min. Width

48"

1219mm)

Min. Height

72"

1829mm)

*see mantle clearance instructions (pages 7 & 8).

MANTEL LEG

CLEARANCES

Combustible mantel leg clearances as per diagram below:

Maximum 1-1/2" projection at 2" minimum clearance.

FRAMING AND

FINISHING

1)Determine the total thickness of facing material (e.g. drywall plus ceramic tiles) to allow the fi nished surface to be fl ush with the front of the unit. Total facing thickness can vary from 1/2" (13mm) to 1-1/4" (32mm) thick.

2)Frame in the enclosure for the unit with framing material. The framed opening is 37-1/4" high x 36-1/4" wide x 17-3/8" deep (946mm high x 921mm wide x 441mm deep).

Framing Dimensions

 

A

B

C

D

 

 

 

 

 

36-1/4"

37-1/4"

17-3/8"

46-1/2"*

 

921mm

946mm

441mm

1181mm*

 

 

 

 

 

* 'D' is Minimum height to combustible materi-

als including the Minimum 2-1/2" (64mm) Top clearance to the Horizontal Vent.

WARNING:

Fire hazard is an extreme risk if

these clearances are not adhered to.

It is of greatest importance that this

fireplace and vent system be

installed only in accordance with

these instructions.

Install Side Nailing Strips, Top Facing Support, and Top Standoffs before unit is slipped into position. See page 9 for as- sembly details.

3)For exterior walls, insulate the enclosure to the same degree as the rest of the house, apply vapour barrier and drywall, as per lo- cal installation codes. (Do not insulate the fireplace itself.)

4)The top of the unit must not be closer than 32" (813mm) to the ceiling.

The HeatWave Duct Kit has different clearance and framing requirements, check the HeatWave manual for details.

UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace

7

Image 7
Contents Unless a certified kit is used Do not touch any electrical switchFrom a neighbours phone. Follow Call the fire departmentTo the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Copy of Safety Decal for G36D-NG Safety LabelSave These Instructions InstallationGeneral Safety Information Installation ChecklistManufactured Mobile Home Additional Requirements Locating Your GAS StoveThis includes Mantel LEG Clearances ClearancesFraming Finishing Combustible Mantels Top Facing Support Side Nailing Strips Unit Assembly Prior to InstallationTop Standoff Assembly Venting IntroductionAir supply outlet VentVenting Description Simpson Dura-Vent Selkirk Rigid Pipe Venting Components ListDirect VentGS R Direct-Temp TM Caps Rigid Pipe Venting SystemsAlternate HorizontalUltraglow Direct Vent System Flex Rigid Pipe Venting Arrangements Horizontal TerminationsInstallation Ridid Pipe Venting Arrangements Vertical Terminations Installation Required Parts Vertical Termination With CO-LINEAR Flex SystemInstallation Snorkel Terminations Horizontal InstallationsContinue to assemble pipe lengths Vertical TerminationOffset Chart Installation ProceduresFor UltraGlow Direct Vent System Flex High Elevation Pilot AdjustmentGAS Line Installation GAS Pipe Pressure TestingBurner Orifi ce 02-75 02-55 02-52 02-50 02-53 02-51 02-54 LOG SET Installation02-54 02-51 02-55 Flush Louvers Standard Flush DoorOptional Flush Trim Wall Thermostat Remote ControlWall Switch Thermostat Wire TableDo not cut the ground terminal off under any circumstances Wiring DiagramTo Remove the Fan Installing the Optional FANOperating Instructions Normal Operating Sounds of GAS Appliances Maintenance InstructionsCopy of the Lighting Plate Instructions Maintenance Removing Valve Installing ValveG36D Main Assembly Parts ListG36D Burner Assembly & LOG SET G36D Flush Front Assembly Conditions WarrantyExclusions Register your UltraGlow online at

G36D-NG NATURAL GAS, G36D-LP PROPANE specifications

The Regency G36D-LP Propane and G36D-NG Natural Gas fireplaces are exemplary models designed to enhance both aesthetic appeal and functional warmth in any home. These innovative units are perfect for individuals looking to add a touch of elegance while enjoying the convenience of modern fireplace technology.

One of the primary features of the G36D series is its impressive heating capability, which can produce up to 34,000 BTUs, making it effective for warming large living spaces. This efficiency is complemented by their design, which allows for rapid heat distribution, ensuring that the warmth is felt throughout the room.

Both models are available in propane and natural gas options, providing flexibility based on user preference or availability. The G36D-LP utilizes propane, making it ideal for homes without a natural gas line, while the G36D-NG is suitable for those connected to a natural gas supply. This adaptability allows homeowners to choose the most economical and convenient fuel source for their needs.

A standout characteristic of the G36D series is its clean, contemporary design. The fireplace features large viewing windows that are bordered by an elegant frame, offering an unobstructed view of the flames. The realistic log set and glowing embers create a visually stunning fire experience that mimics the ambiance of a traditional wood-burning fireplace without the associated maintenance.

The fireplaces are also equipped with state-of-the-art technology, including a reliable electronic ignition system, which ensures easy starts every time while enhancing safety. The G36D series features adjustable flame height settings, allowing users to customize their experience based on preference or room ambiance.

In terms of efficiency, the G36D fireplaces boast an annual fuel utilization efficiency (AFUE) rating that meets modern energy standards. This characteristic not only contributes to environmental sustainability but also results in lower utility costs over time.

Moreover, the G36D series is designed with a user-friendly interface, allowing homeowners to operate their fireplace with ease. With optional remote controls and wall switches available, adjusting the settings has never been more convenient.

The Regency G36D-LP and G36D-NG are perfect for those who seek the charm of a fireplace with the benefits of modern innovation. Their blend of aesthetic appeal, advanced technology, and efficient heating makes them a standout choice for any homeowner looking to enhance their living space.