Regency G36D-LP PROPANE, G36D-NG NATURAL GAS installation manual Operating Instructions

Page 32

OPERATING INSTRUCTIONS

OPERATING

INSTRUCTIONS

1)Read and understand these instructions before operating this appliance.

2)Check to see that all wiring is correct and enclosed to prevent possible shock.

3)Check to ensure there are no gas leaks.

4)Make sure the glass in the door frame is properly positioned. Never operate the ap- pliance with the glass removed.

5)Verify that the venting and cap are unob- structed.

6)Ensure that the brick panels are installed.

7)Verify log placement. If the pilot cannot be seen when lighting the unit, the logs have been incorrectly positioned.

8)The unit should never be turned off, and on again without a minimum of a 60 second wait.

2)Turn gas control knob so indicator points to "OFF" position and allow 5 minutes for any gas in the combustion chamber to escape.

3)Turn gas control knob counterclockwise so indicator points to the "PILOT" position. Depress the gas control knob fully. Depress the igniter button several times until the pilot lights.After approximately one minute, release the gas control knob.The pilot flame should continue to burn. If the pilot does not remain lit, repeat operation allowing a longer period before releasing gas control knob.

4)When the pilot stays lit, turn the gas knob further counterclockwise to the "ON" posi- tion.

5)Use the wall switch, thermostat or remote control to turn on the unit.

6)Rotate the fl ame height regulator to adjust the fl ame height higher or lower.

SHUTDOWN

PROCEDURE

1)Use the wall switch, thermostat or remote control to turn off the main burner.

2)Turn the main gas control clockwise to the "OFF" position to turn off the pilot.

3)Turn off all electric power to appliance if service is to be performed.

DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE.

During the first few fires, a white film may develop on the glass front as part of the curing process. The glass should be cleaned or the film will bake on and become very difficult to remove. Use a non-abrasive cleaner and NEVER clean the glass while it is hot.

AERATION

ADJUSTMENT

The air shutter can be adjusted by moving the adjusting wire up or down.The wire is accessed through the bottom louver opening. Open the air shutter for a blue fl ame or close for a yel- lower fl ame. The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude.

Minimum Air Shutter Opening:

3/16" Natural Gas

1/2" Propane

CAUTION:Carbonwillbeproducedifairshutter is closed too much.

Note: Any damage due to carboning resulting from improperly setting the aeration controls is NOT covered under warranty.

Note: AerationAdjustment should only be performedbyanauthorizedRegency Installer at the time of installation or service.

LIGHTING

PROCEDURE

IMPORTANT

To ignite or reignite the pilot, you must first release the ten- sion springs below the door.

Only when the pilot holds, without pressure being applied to the control knob, reapply the tension springs to the door. The unit must not be operated with the tension springs unattached.

IMPORTANT Gas cock knob cannot be turned from "PILOT" to "OFF" unless it is partially depressed.

1)Turn burner OFF using "ON/OFF" switch.

FIRST FIRE

The fi rst fi re in your stove is part of the paint cur- ing process. To ensure that the paint is properly cured, it is recommended that you burn your

replace for at least four (4) hours the fi rst time before you use it with the fan on.

When fi rst operated, the unit will release an odour caused by the curing of the paint, the burning off of any oils remaining from manufac- turing. Smoke detectors in the house may go off at this time. Open a few windows to ventilate the room for a couple of hours.

The glass panel may require cleaning after the unit has cooled down. DO NOTATTEMPT

TO CLEAN THE GLASS WHILE IT IS HOT.

Note: When the glass is cold and the appli- ance is lit, itmaycause condensation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up.

Adjustment Wire: push to close or

pull to open aeration cap.

Closed - Tall yellow

Open - Short Blue

32

UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace

Image 32
Contents Do not touch any electrical switch From a neighbours phone. FollowCall the fire department Unless a certified kit is usedInformation for MOBILE/MANUFACTURED Homes After First Sale To the New OwnerTable of Contents Safety Label Copy of Safety Decal for G36D-NGInstallation General Safety InformationInstallation Checklist Save These InstructionsThis includes Locating Your GAS StoveManufactured Mobile Home Additional Requirements Framing Finishing ClearancesMantel LEG Clearances Combustible Mantels Unit Assembly Prior to Installation Top Standoff AssemblyVenting Introduction Top Facing Support Side Nailing StripsVent Air supply outletVenting Direct VentGS R Direct-Temp TM Rigid Pipe Venting Components ListDescription Simpson Dura-Vent Selkirk Rigid Pipe Venting Systems AlternateHorizontal CapsRigid Pipe Venting Arrangements Horizontal Terminations Ultraglow Direct Vent System FlexInstallation Ridid Pipe Venting Arrangements Vertical Terminations Installation Vertical Termination With CO-LINEAR Flex System Required PartsInstallation Horizontal Installations Snorkel TerminationsVertical Termination Continue to assemble pipe lengthsFor UltraGlow Direct Vent System Flex Installation ProceduresOffset Chart Pilot Adjustment GAS Line InstallationGAS Pipe Pressure Testing High ElevationBurner Orifi ce LOG SET Installation 02-75 02-55 02-52 02-50 02-53 02-51 02-5402-54 02-51 02-55 Optional Flush Trim Standard Flush DoorFlush Louvers Remote Control Wall SwitchThermostat Wire Table Wall ThermostatWiring Diagram Do not cut the ground terminal off under any circumstancesInstalling the Optional FAN To Remove the FanOperating Instructions Copy of the Lighting Plate Instructions Maintenance InstructionsNormal Operating Sounds of GAS Appliances Maintenance Installing Valve Removing ValveParts List G36D Main AssemblyG36D Burner Assembly & LOG SET G36D Flush Front Assembly Exclusions WarrantyConditions Register your UltraGlow online at

G36D-NG NATURAL GAS, G36D-LP PROPANE specifications

The Regency G36D-LP Propane and G36D-NG Natural Gas fireplaces are exemplary models designed to enhance both aesthetic appeal and functional warmth in any home. These innovative units are perfect for individuals looking to add a touch of elegance while enjoying the convenience of modern fireplace technology.

One of the primary features of the G36D series is its impressive heating capability, which can produce up to 34,000 BTUs, making it effective for warming large living spaces. This efficiency is complemented by their design, which allows for rapid heat distribution, ensuring that the warmth is felt throughout the room.

Both models are available in propane and natural gas options, providing flexibility based on user preference or availability. The G36D-LP utilizes propane, making it ideal for homes without a natural gas line, while the G36D-NG is suitable for those connected to a natural gas supply. This adaptability allows homeowners to choose the most economical and convenient fuel source for their needs.

A standout characteristic of the G36D series is its clean, contemporary design. The fireplace features large viewing windows that are bordered by an elegant frame, offering an unobstructed view of the flames. The realistic log set and glowing embers create a visually stunning fire experience that mimics the ambiance of a traditional wood-burning fireplace without the associated maintenance.

The fireplaces are also equipped with state-of-the-art technology, including a reliable electronic ignition system, which ensures easy starts every time while enhancing safety. The G36D series features adjustable flame height settings, allowing users to customize their experience based on preference or room ambiance.

In terms of efficiency, the G36D fireplaces boast an annual fuel utilization efficiency (AFUE) rating that meets modern energy standards. This characteristic not only contributes to environmental sustainability but also results in lower utility costs over time.

Moreover, the G36D series is designed with a user-friendly interface, allowing homeowners to operate their fireplace with ease. With optional remote controls and wall switches available, adjusting the settings has never been more convenient.

The Regency G36D-LP and G36D-NG are perfect for those who seek the charm of a fireplace with the benefits of modern innovation. Their blend of aesthetic appeal, advanced technology, and efficient heating makes them a standout choice for any homeowner looking to enhance their living space.