Wayne 350800-002 Troubleshooting Chart, Maintenance, Symptom Possible Causes Corrective Action

Page 2

Operating Instructions And Parts Manual

2.This pump is only for use on 120 Volt (single-phase), 60 hz, 15 amp service and is equipped with a 3-conductor cord and 3-prong, grounding type plug. Insert the float switch cord plug directly into a 120 volt outlet.

3.Insert the pump power cord plug directly into the back of the float switch cord plug (See Fig. 2).

4.Fill sump with water. The pump will start automatically when the water has filled the sump to the cut-in level. The pump will stop when the water reaches the cut-out level. See specifications for cut-in/out levels. The pump will cycle thereafter as required.

Do not operate the pump unless it is

submerged in water. Dry running causes pump failure.

The motor is equipped with an

automatic reset thermal protector.

5.While the pump is draining the pit, verify that the discharge piping is carrying the water to a point several feet away from the foundation.

If pump discharge line is exposed to freezing temperature, the exposed line

must be pitched to drain. Trapped water will freeze and damage the pump.

Maintenance

Always disconnect the electrical supply before attempting to install, service, relocate or

perform any maintenance. If the power source is out of sight, lock and tag in the open (off) position to prevent unexpected power application. Failure to do so could result in fatal electrical shock. Only qualified electricians

should repair this unit. Improper repair could result in fatal electrical shock.

1.Let the pump cool for a minimum of two hours before servicing because the pump contains hot oil under pressure and the motor is hot.

2.Disassembly of the motor prior to expiration of warranty will void the warranty. If repairs are required, see troubleshooting chart.

3.Inlet should be kept clean and free of all foreign objects and inspected annually. A clogged inlet will damage the pump.

4.Pump should be checked monthly for proper operation.

This pump contains dielectric oil for

cooling. This oil can be harmful to the environment. Check the state environmental laws before disposing this oil.

Troubleshooting Chart

Symptom

Possible Cause(s)

Corrective Action

 

 

 

 

 

Pump will not start

1. Blown fuse

1. If blown, replace with proper sized fuse or reset breaker

 

or run

2. Low line voltage

2. If voltage is under 108 volts, check wiring size

 

 

3. Defective motor

3. Replace pump

 

 

4. Defective float switch

4. Replace float switch

 

 

5. Impeller bound-up

5. If impeller will not turn, remove housing and remove

 

 

 

blockage

 

 

6. Float obstructed

6. Make sure float moves freely up and down

 

 

 

 

 

Pump starts and

1. Backflow of water from

1. Install or replace check valve (Blue Angel™ check valve kit

 

stops too often

piping

#66005-WYN)

 

 

2. Faulty float switch

2. Replace float switch

 

 

 

 

 

Pump will not shut

1. Defective float switch

1. Replace float switch

 

off or thermal

2. Obstacle in piping

2. Remove pump and clean pump and piping

 

protector turns off

3. Float obstructed

3. Make sure float move freely up and down

 

 

 

 

 

Pump operates but

1. Low line voltage

1. If voltage is under 108 volts, check wiring size

 

delivers little or no

2. Plugged impeller

2. Clean out impeller

 

water

3. Obstructed piping

3. Remove pump and remove obstruction from piping or

 

 

 

reposition piping to prevent obstruction

 

 

4. Excessive lift height

4. Reposition pump to a suitable position to decrease lift

 

 

(water has to go higher

height

 

 

than pump can handle)

 

 

www.blueangelpumps.com

2

Image 2
Contents Description General Safety InformationInstallation OperationSymptom Possible Causes Corrective Action Troubleshooting ChartMaintenance Parts Numbers Description RSP-130Limited Warranty Dia. Min Généralités Sur La Sécurité InstallationFonctionnement Entretien Guide De DépannageFonctionnement Suite Symptôme Causes Possibles Mesures CorrectivesListe De Pièces De Rechange SpécificationsFabrication Nº de Numéros de Pièces Réf Description RSP-130Garantie Limitée Instalación DescripciónInformaciones Generales de Seguridad FuncionamientoFuncionamiento Continuación Problema Posibles Causas Acción a tomarGuía de diagnóstico de averías MantenimientoLista de repuestos EspecificacionesMateriales de fabricación No. de Número de Piezas Descripción RSP-130Garantía Limitada No Envie Estos Datos a WAYNE. Conserve esto sólo como datos

350800-002, BRSPT130, ESP25 specifications

The Wayne ESP25,350800-002,BRSPT130 is a cutting-edge product designed for efficiency and adaptability in various applications. This advanced equipment leverages state-of-the-art technologies to deliver optimal performance, whether it is being used in commercial, industrial, or residential settings.

One of the standout features of the Wayne ESP25 is its powerful motor. Capable of dealing with demanding tasks, the motor offers robust performance that ensures reliable operation over extended periods. This feature is particularly beneficial in environments where uninterrupted functionality is crucial.

The unit's design employs high-quality materials that enhance its durability, making it suitable for use in challenging conditions. Its rugged construction not only extends its lifespan but also reduces maintenance needs, allowing users to focus on productivity rather than frequent repairs or replacements.

In terms of technology, Wayne has integrated advanced monitoring and control systems. These systems provide real-time feedback and diagnostics, enabling users to track performance metrics and identify potential issues before they escalate. The intuitive interface ensures that even those who may not be technically inclined can operate the system with ease.

Another notable characteristic of the ESP25 is its energy efficiency. Designed with sustainability in mind, this model utilizes energy-conserving technologies that help minimize operational costs. By reducing energy consumption, it not only supports eco-friendly initiatives but also provides significant savings for users over time.

Moreover, the Wayne ESP25,350800-002,BRSPT130 has been crafted with versatility in mind. It can be adapted for various applications, from hydraulic systems to sprinkler setups, making it a perfect choice for diverse industries. This flexibility enhances its appeal, allowing businesses to invest in one reliable piece of equipment that meets multiple needs.

The device is also equipped with user-friendly features such as quick disconnect options and simple installation procedures. This attribute not only simplifies initial setup but also facilitates quick changes or upgrades, further adding to its functionality.

In conclusion, the Wayne ESP25,350800-002,BRSPT130 combines powerful performance with advanced technologies and user-oriented design. Its efficiency, durability, and adaptability make it a compelling choice for anyone seeking reliable equipment that can meet the demands of a variety of applications. By investing in this product, users gain a dependable tool that optimizes productivity while minimizing costs.