Cooline PT360 manual Model Decoding, Models PT036 PT060 Direct Drive Motor

Page 3

MODEL DECODING

MODELS: PT036 - PT060 (DIRECT DRIVE MOTOR)

1& 2

3, 4 & 5

6

7

8

9

10

11

12

13

14

15

BASIC

NOMINAL

ELECTRICAL

REFRIGERA-

BLOWER

DRIVE

HEATER

EVAPORATOR

CONDENSER

PDS

OTHER

UNIT

 

COOLING

SUPPLY

TION CIRCUIT

MOTOR

OPTIONS

OPTIONS

COIL

COIL

OPTION

OPTIONS

ACCESSORIES

 

CAPACITY

( V-Ph-Hz )

 

 

 

(kW/STAGE)

 

 

 

 

 

 

(MBH)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PT

036

L : 380/415-3-50

S : SINGLE

W : 0.75 HP ODP

N : DIRECT

N : NO HEATER

J : IGT + ENHANCED

J : IGT + ENHANCED

N : NO PDS

N : STANDARD UNIT

N : STANDARD UNIT

COOLINE

 

(4 WIRE)

 

 

DRIVE

A : 5/1

AL. FINS

AL. FINS

OPTION

I : ANTI-ICE

C :FRESH AIR

PACKAGED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

048

 

 

W : 0.75 HP ODP

 

B : 6/1

K :IGT + ENHANCED

K : IGT + ENHANCED

P : PDS OPTION

 

MANUAL

UNIT

 

 

 

 

 

 

 

U :UVM

DAMPER

 

 

 

 

 

 

 

MHG. FINS

MHG. FINS

 

 

 

 

 

Y : 1 HP ODP

 

C : 7.5/1

 

 

 

060

 

 

 

 

 

 

 

 

 

 

 

 

D : 10 /2

L : IGT + CORRU-

L : IGT + CORRU-

 

V : VOLT FREE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E : 12/2

GATED CU. FINS

GATED CU. FINS

 

CONTACT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODELS: PT075 - PT360 (BELT DRIVEN MOTOR)

 

1& 2

3, 4 & 5

6

7

8

9

10

11

12

13

14

15

 

BASIC

NOMINAL

ELECTRICAL

REFRIGERA-

BLOWER

DRIVE

HEATER

EVAPORATOR

CONDENSER

PDS

OTHER

UNIT

 

 

COOLING

SUPPLY

TION CIRCUIT

MOTOR

OPTIONS

OPTIONS

COIL

COIL

OPTION

OPTIONS

ACCESSORIES

 

 

CAPACITY

( V-Ph-Hz )

 

 

 

(kW/STAGE)

 

 

 

 

 

 

 

(MBH)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PT

075

L : 380/415-3-50

S : SINGLE

C : 1.5 HP ODP

J : ALT. I

N : NO HEATER

J : IGT + ENHANCED

J : IGT + ENHANCED

N : NO PDS

N : STANDARD UNIT

N : STANDARD UNIT

 

COOLINE

 

(4 WIRE)

 

D : 2 HP ODP

 

A : 5/1*

AL. FINS

AL. FINS

OPTION

 

 

 

 

 

K : ALT. II

B : 6/1*

I : ANTI-ICE

C :FRESH AIR

 

PACKAGED

 

 

 

 

 

 

090

 

D :DUAL

D : 2 HP ODP

C : 7.5/1

K :IGT + ENHANCED

K : IGT + ENHANCED

P : PDS OPTION

MANUAL

 

 

 

 

 

 

UNIT

 

 

D : 10 /2

U :UVM

DAMPER

 

 

100

 

 

E : 3 HP ODP

 

E : 12/2

MHG. FINS

MHG. FINS

 

 

 

 

120***

 

 

F : 3 HP TEFC

 

F : 15 /2

 

 

 

 

 

2

 

 

 

 

G : 20 /2

L : IGT + CORRU-

L : IGT + CORRU-

 

V : VOLT FREE

 

 

 

 

 

 

G : 5 HP ODP

 

C : 7.5/1

GATED CU. FINS

GATED CU. FINS

 

CONTACT

 

 

 

180

 

 

 

 

 

 

 

 

 

 

H : 5 HP TEFC

 

D : 10 /2

 

 

 

 

 

 

 

215

 

 

 

E : 12/2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J : 7.5 HP ODP

 

F : 15 /2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K : 7.5 HP TEFC

 

G : 20 /2

 

 

 

 

 

 

 

 

 

 

 

H : 25/2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

240

 

 

J : 7.5 HP ODP

 

J : 30/2**

 

 

 

 

 

 

 

 

 

K : 7.5 HP TEFC

 

 

 

 

 

 

 

 

 

300

 

 

 

 

 

 

 

 

 

 

 

 

 

L : 10 HP ODP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M : 10 HP TEFC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

360

 

 

L : 10 HP ODP

 

 

 

 

 

 

 

 

 

 

 

 

M : 10 HP TEFC

 

 

 

 

 

 

 

 

 

 

 

 

N : 15 HP ODP

 

 

 

 

 

 

 

 

 

 

 

 

P : 15 HP TEFC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: * – Applicable for PT075 models only.

**– Applicable for models PT180 & above only.

***– 3 HP motor only available for PT120.

Image 3
Contents Installation Operation Maintenance Manual Index ContentsModel Decoding Models PT036 PT060 Direct Drive MotorModels PT075 PT360 Belt Driven Motor General Statement WarrantySafety Issues GeneralInstallation Instructions GeneralLocation of Unit Rigging Instructions Models PT036 PT120 Models PT180 PT360Models PT036 PT360 Electric Heaters Unit Weight & Weight DistributionCondensate Drain Connection Duct ConnectionPT036 PT075 Unit DimensionsPT090 PT120 TOP View Side View Front View PT180PT215 PT240 PT300 PT360 Operation Instructions Cable SizeSTART-UP Inspection & Check List Models PT100 & PT120 Electrical DataModels PT036 PT060 Models PT075 & PT090Models PT180 & PT215 Models PT240 & PT300Model PT360 Electronic Thermostat AUTO/MANUAL Reset of the Alarm SignalsPump Down Control Crankcase HeaterCleaning of Coils & Filters Maintenance InstructionsBelt Tension Checker Measure the Belt Deflection Force Typical High and LOW Voltage Field Wiring ConnectionsBelt Tension Testing Procedure BeltsE M Preventive Maintenance ScheduleMaintenance TOOLS/EQUIPMENT Required Frequency of MAINTENANCE, MonthsSymptom Causes Check & Corrective Measure Trouble Shooting ChartUnit works continuously, no sufficient Low suction pressure Models PT036 PT075 Single compressor units Typical Schematic Wiring DiagramAuxiliary Relay Models PT090 PT120 Dual compressor units Connection Applicable for Volt Free Contact Options Models PT180 PT240 Dual compressor units Standard Options 1. UVM Option Models PT300 PT360 Dual compressor units Terminal Block or Termination Point Optional Items Parts ListModel Number PT240L PT300L PT360L