Bell Sports PQRY-P72-96TGMU-A installation manual Confirmation of parts attached, Lifting method

Page 8

4. Confirmation of parts attached

1

Connecting pipe 1 (Connecting pipe is fixed with the unit.)

2 Packing (inside ø23 [29/32 in], outside ø35 [1-13/32 in]) 1

3

Bushing 2

 

5. Lifting method

[Fig. 5.0.1] (P.2)

Caution:

Be very careful when carrying the product.

-Do not have only one person to carry product if it is more than 20 kg [46 LBS].

-PP bands are used to pack some products. Do not use them as a mean for transportation because they are dangerous.

-Tear plastic packaging bag and scrap it so that children cannot play with it. Otherwise plastic packaging bag may suffocate children to death.

-When carrying the heat source unit, be sure to support it at four points. Carrying with 3-point support may make the heat source unit unstable, resulting in it falling.

6. Installation of unit and service space

GB

6.1. Installation

Using the anchoring holes shown below, firmly bolt the unit to the base.

[Fig. 6.1.1] (P.2)

A

Heat source unit

B 4-ø14 [9/16] (Anchoring hole)

C

(Top view)

 

Bases and anti-vibration

Be sure to install unit in a place strong enough to withstand its weight. If the base is unstable, reinforce with a concrete base.

The unit must be anchored on a level surface. Use a level to check after installation.

Anti-vibration pads must be placed under the base of the unit.

If the unit is installed near a room where noise is a problem, using an anti- vibration stand on the base of the unit is recommended.

[Fig. 6.1.2] (P.2)

D Anti-vibration pad etc.

E Concrete base

Warning:

Be sure to install unit in a place strong enough to withstand its weight. Any lack of strength may cause unit to fall down, resulting in a personal injury.

Have installation work in order to protect against earthquake.

Any installation deficiency may cause unit to fall down, resulting in a personal injury.

6.2. Service space

Please allow for the following service spaces after installation. (All servicing can be performed from the front of the unit)

[Fig. 6.2.1] (P.2)

A

Piping space (for side piping)

B

Heat source unit

C

Service space (front side)

D

(Top view)

[Fig. 6.2.2] (P.2)

E

Piping space (for top piping)

F

Piping space (for side piping)

G

Heat source unit

H

(Front view)

7. Water pipe installation

City Multi WR2 Series pipes are similar to other air-conditioning pipes, how- ever, please observe the following precautions during installation.

7.1. Precautions during installation

Use the reverse-return method to insure proper pipe resistance to each unit.

To insure easy maintenance, inspection, and replacement of the unit, use a proper joint, valve, etc. on the water intake and outlet port. In addition, be sure to install a strainer on the water intake pipe. (In order to maintain the heat source unit, a strainer on the circulating water inlet is necessary.)

* An example of the heat source unit installation is shown in the diagram be- low.

Install a suitable air vent on the water pipe. After sending water through the pipe, be sure to vent the excess air.

Compressed water may form in the low-temperature sections of heat source unit. Use a drainage pipe connected to the drain valve at the base of the unit to drain the water.

There is a water vent plug in the center of the heat exchanger water inlet head at the middle of the unit. Use this for maintenance, etc.

In addition, do not allow any of the unit’s electrical parts (such as the solenoid valve coil or compressor power supply) to become wet.

Install a back flow-prevention valve on the pump and a flexible joint to prevent excess vibration.

Use a sleeve to protect the pipes where they go through a wall.

Use metal fittings to secure the pipes, and install them so that they have maxi- mum protection against breakage and bending.

Do not confuse the water intake and outlet valves.

This unit doesn’t have any heater to prevent freezing within tubes. When the water flow is stopped on low ambient, take out the water from tubes.

The unused knockout holes should be closed and the opening of refrigerant pipes, water pipes, power source and transmission wires should be filled with putty and so on to prevent from rain. (field construction)

Example of heat source unit installation (using left piping)

[Fig. 7.1.1] (P.2)

A Water circulation pipe

B Close valve

C Close valve

D Water outlet

E

Refrigerant piping

F

Y-type strainer

G

Water inlet

H

Drain pipe

7.2. Insulation installation

With City Multi WR2 Series piping, as long as the temperature range of the circu- lating water is kept to average temperatures year-round (30 °C [86 °F] in the sum- mer, 20 °C [68 °F] in the winter), there is no need to insulate or otherwise protect indoor piping from exposure. You should use insulation in the following situations:

Any heat source piping.

Indoor piping in cold-weather regions where frozen pipes are a problem.

When air coming from the outside causes condensation to form on piping.

Any drainage piping.

7.3.Water processing and water quality con-

trol

To preserve water quality, use the closed type of cooling tower for WR2. When the circulating water quality is poor, the water heat exchanger can develop scales, leading to a reduction in heat-exchange power and possible corrosion of the heat exchanger. Please pay careful attention to water processing and water quality control when installing the water circulation system.

Removal of foreign objects or impurities within the pipes.

During installation, be careful that foreign objects, such as welding fragments, sealant particles, or rust, do not enter the pipes.

Water Quality Processing

1 Depending on the quality of the cold-temperature water used in the air- conditioner, the copper piping of the heat exchanger may become corroded. We recommend regular water quality processing.

Cold water circulation systems using open heat storage tanks are particularly prone to corrosion.

When using an open-type heat storage tank, install a water-to-water heat exchanger, and use a closed-loop circuit on the air conditioner side. If a water supply tank is installed, keep contact with air to a minimum, and keep the level of dissolved oxygen in the water no higher than 1mg/r.

8

Image 8
Contents PQRY-P72·96TGMU-A = 8 m 26 ft Side piping Top pipingUnit mm 55 ~High press Low press ¬ Liquid pipe Gas pipe Ø15.88 5/8 Ø9.52 3/810.2 10.3 10.4Contents Safety precautionsSpecifications Before getting installedBefore installation electrical work About the productInstallation of unit and service space Water pipe installationConfirmation of parts attached Lifting methodRefrigerant piping system Refrigerant piping installationPump interlock Additional refrigerant charge Calculation of additional refrigerant chargeAirtight test, evacuation, and refrigerant charging Airtight testOnly use refrigerant R410A EvacuationWiring Control box and connecting position of wiringWiring transmission cables Thermal insulation of refrigerant pipingWiring examples Transmission boosterWiring of main power supply and equipment capacity Test runInformation on rating plate Following phenomena do not represent trouble emergencyTable des matières Consignes de sécuritéAvant d’effectuer l’essai Avant de procéder à l’installationAvant de procéder à l’installation élec- trique Installation de l’appareil et espace de service Le produitAssociation aux appareils intérieurs Vérification des pièces livréesInstallation du tuyau d’eau Précautions à prendre pendant l’instal- lationMise en place de l’isolation Traitement de l’eau et contrôle de la qualité de l’eauInstallation des tuyaux de réfrigérant PrécautionSystème de mise en place des tuyaux de réfrigérant Faites très attention lors de l’utilisation d’outilsCharge supplémentaire de réfrigérant Calcul de la charge supplémentaire de réfrigérantNe pas utiliser de liquide de détection de fuite Test d’étanchéité à l’air10.1. Précaution 10. CâblageIsolation thermique des tuyaux de ré- frigérant Types de câbles de commande Commande à distance M-NETCommande à distance MA Mise en place des câbles de transmis- sionAuxiliaire de transmission Schéma du câblage exempleInformations sur la plaque signalétique Essai de fonctionnementPage Page WT04680X01

PQRY-P72-96TGMU-A specifications

The Bell Sports PQRY-P72-96TGMU-A is a state-of-the-art sports helmet designed for athletes who prioritize safety without compromising on comfort and style. This helmet harnesses advanced technologies and design features that elevate it beyond conventional sports headgear, making it a popular choice for both recreational and professional use.

One of the standout features of the PQRY-P72-96TGMU-A is its multi-layered shell construction. This innovative design effectively disperses impact forces while maintaining lightweight characteristics, ensuring that athletes can enjoy maximum protection without the burden of added weight. The outer shell is not only durable but also engineered to resist scratches and abrasions, keeping the helmet looking good despite rigorous use.

The interior of the helmet incorporates a sophisticated foam padding system that conforms to the shape of the athlete's head, providing a snug yet comfortable fit. This customization is crucial for reducing movement during activity, which enhances both comfort and protection. The padding also features moisture-wicking properties to keep wearers cool and dry, critical during intense physical exertion.

Safety is further enhanced by the inclusion of advanced ventilation systems. Strategically placed vents help maintain airflow, preventing overheating and ensuring that athletes can focus on their performance. The helmet's aerodynamic design minimizes drag as well, allowing for smoother movements and improved overall efficiency.

In terms of aesthetics, the Bell Sports PQRY-P72-96TGMU-A boasts an array of vibrant colors and sleek graphics. This versatility allows athletes to express their personal style while benefiting from the helmet's high-performance capabilities. The helmet also comes equipped with an adjustable chin strap, ensuring a secure fit for users of various sizes.

Additionally, the PQRY-P72-96TGMU-A is compatible with various accessories and add-ons, which can enhance its functionality. This adaptability is particularly appealing for those who wish to customize their helmet for specific sports or personal preferences.

In summary, the Bell Sports PQRY-P72-96TGMU-A is an exemplary sports helmet that stands out due to its combination of safety features, innovative technologies, and stylish designs. Whether for competitive sports or recreational activities, this helmet represents a smart investment for anyone seeking superior protection and comfort.