Auto restart

In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions.

So there is no need of activating this function by pressing any key or button.

In the initial mode, the fan operates at a low speed and the compressor starts 2.5~3 minutes later. As the compressor starts, the fan speed also resumes its previous setting mode.

Helpful information

 

Fan speed and cooling capacity.

 

The cooling capacity indicated in the specification is the value

 

when the fan speed is set to high, and the capacity will be lower

High

at low or medium fan speed.

Speed

High fan speed is recommended when you wish to cool the room

 

quickly.

 

NOTICE

Auto restart function has set enable as factory default.

But customer can set up by following this instruction.

To disable function

-Press and hold the ON/OFF button for 6 seconds, then the buzzer sound 2 "beep" and the indicator lamp (1) blinks 4 times.

To enable function

-Press and hold the ON/OFF button for 6 seconds, then the buzzer sound 2 "beep" and the indicator lamp (1) brights 4 times.

ENGLISH

Owner’s Manual 25

Image 25
Contents Room Air Conditioner Table of Contents Be sure not to do Be sure to follow the instruction Safety PrecautionsThere is risk of fire or electric shock There is risk of electric shockCould cause personal injury Personal injury Explosion, or injury Damage to the product EdgesShock Oxygen deficiency could occur There is risk of fire or product failureThere is risk of explosion or fire There is risk of electrical shockThere is risk of fire or electrical shock It may cause a problem for your neighborsBad connection may cause water leakage To avoid vibration or water leakageThis could damage your health Avoid personal injuryProduct There is risk of personal injuryThere is risk of fire or explosion Be careful and avoid personal injuryThey may burn or explode Prior To Operation ServicePreparing For Operation UsageFeatures Symbols Used In This ManualIntroduction IndoorElectrical Safety Operating Instruction Controls Remote Control OperationsGentle Breeze by the Chaos logic Cooling operationDuring Auto Operation Auto operation OptionalDuring Auto Changeover Operation Auto changeover operationOptionalHealthy dehumidification operation Fan speed mode is shiftedDuring Healthy Dehumidification Operation Temperature can be set within a range Close the door of the remote controllerRemote controller still closed. You can Heating operation Heat pump model onlyJet cool operation NEO Plasma Air Purifying Operation only NEO Plasma purification operationOptionalButton is pressed again 2nd F operationSleep mode Additional FeaturesSetting the time Delay start/Pre-set stopVertical Airflow Direction Control Adjust the left/right airflow direction by handForced operation Auto clean OptionalTest operation 22C71.6F 23C73.4F 24C75.2FTo enable function To disable functionAuto restart Helpful informationIndoor Unit Maintenance And ServiceAir conditioner is operating normally when Outdoor UnitAir conditioner may be operating abnormally when TroubleshootingAir conditioner does not start Air conditioner does not cool as it shouldNo A20434H