Reliance Water Heaters 606 Series Burner Cleaning, Housekeeping, Anode ROD Inspection, Draining

Page 25

BURNER CLEANING

If inspection of the burner shows that cleaning is required, turn

the gas control knob clockwise ( ) to the “OFF” position, depressing slightly.

NOTE: The knob cannot be turned from “PILOT” to “OFF” unless knob is depressed slightly. DO NOT FORCE.

Loose deposits on or around the burner can be removed by carefully using the hose of a vacuum cleaner inserted through the access door of the water heater. If the burner needs to be removed for additional cleaning, call a service agency to remove and clean the burner and correct the problem that required the burner to be cleaned.

HOUSEKEEPING

Vacuum around base of water heater for dust, dirt, and lint on a regular basis.

INSTALLED IN SUITABLE AREA: To insure sufficient ventilation and combustion air supply, proper clearances from the water heater must be maintained. See “Locating the New Water Heater” section. Combustible materials such as clothing, cleaning materials, or flammable liquids, etc. must not be placed against or adjacent to the water heater which can cause a fire.

ANODE ROD INSPECTION

The anode rod is used to protect the tank from corrosion. Most hot water tanks are equipped with an anode rod. The submerged rod sacrifices itself to protect the tank. Instead of corroding the tank, water ions attack and eat away the anode rod. This does not affect the water’s taste or color. The rod must be maintained to keep the tank in operating condition.

Anode deterioration depends on water conductivity, not necessarily water condition. A corroded or pitted anode rod indicates high water conductivity and should be checked and/ or replaced more often than an anode rod that appears to be

intact. Replacement of a depleted anode rod can extend the life of your water heater. Inspection should be conducted by a qualified technician, and at a minimum the anode(s) should be checked annually after the warranty period.

TEMPERATURE-PRESSURE

RELIEF VALVE OPERATION

The temperature-pressure relief valve must be manually operated at least once a year.

When checking the temperature-pressure relief valve operation, make sure that (1) no one is in front of or around the outlet of the temperature-pressure relief valve discharge line, and (2) that the water discharge will not cause any property damage, as the water may be extremely hot, see Figure 34.

FIGURE 34.

If after manually operating the valve, it fails to completely reset and continues to release water, immediately close the cold water inlet to the water heater, follow the draining instructions, and replace the temperature-pressure relief valve with a new one.

If the temperature-pressure relief valve on the appliance weeps or discharges periodically, this may be due to thermal expansion. You may have a check valve installed in the water line or a water meter with a check valve. Consult your local water supplier or service agency for further information. Do not plug the temperature-pressure relief valve.

DRAINING

25

Image 25
Contents Residential GAS Water Heaters Important Definitions Safe INSTALLATION, USE and ServiceGeneral Safety Introduction Table of ContentsGET to Know Your Water Heater GAS Models Typical InstallationMixing Valve Usage Removing the OLD Water Heater Materials and Basic Tools Needed Deciding on the Type of InstallationFacts to Consider about the Location Locating the NEW Water HeaterInsulation Blankets ALL AIR from Inside Buildings See Figures 10 Page Section a Galvanized Piping Installing the NEW Water HeaterSection B Copper Sweat Piping Page TEMPERATURE-PRESSURE Relief Valve Venting Filling the Water HeaterGAS Piping Sediment Traps GAS Piping with Flexible ConnectorFor Your Safety Read Before Lighting For Your Safety Read Before Lighting For Your Information Temperature RegulationStart UP Conditions Draft Hood OperationThermal Expansion Smoke / OdorStrange Sounds Smelly WaterHigh Water Temperature Shut OFF System Periodic MaintenanceVenting System Inspection Burner InspectionTEMPERATURE-PRESSURE Relief Valve Operation Burner CleaningHousekeeping Anode ROD InspectionService Drain Valve Washer ReplacementLeakage Checkpoints Problem Cause Solution Troubleshooting GuidelinesDrain PAN Repair Parts ListT&P Relief Valve Model Series Service and Labor ResponsibilityConditions and Exceptions Installation Information Claim ProcedureLimitation on Implied Warranties DisclaimersLindahl Parkway Ashland City, TN