The water heater should be drained if being shut down during freezing temperatures. Also periodic draining and cleaning of sediment from the tank may be necessary.
1.Turn the gas control knob to the “OFF” position.
2.CLOSE the cold water inlet valve to the water heater.
3.OPEN a nearby hot water faucet and leave open to allow for draining.
4.Connect a hose to the drain valve and terminate to an adequate drain.
5.OPEN the water heater drain valve to allow for tank draining.
NOTE: If the water heater is going to be shut down and drained for an extended period, the drain valve should be left open with hose connected allowing water to terminate to an adequate drain.
6.Close the drain valve.
7.Follow instructions in the “Filling The Water Heater” section.
8.Follow the lighting instructions on the label or see pages 20 and 21 under “Lighting and Operating Instructions” to restart the water heater.
DRAIN VALVE WASHER REPLACEMENT-
FOR SELECTED MODELS WITH PLASTIC DRAIN VALVES
(See Figure 35)
1.Turn “OFF” gas supply to water heater.
2.Follow “Draining” instructions.
3.Turning counter clockwise ( ), remove the hex cap below the screw handle.
4.Remove the washer and put the new one in place.
5.Screw the handle and cap assembly back into the drain
valve and retighten using a wrench. DO NOT OVER TIGHTEN.
6.Follow instructions in the “Filling The Water Heater” section.
7.Check for leaks.
8.Follow the lighting instructions in the “Lighting and Operating Instructions” section to restart the water heater.
FIGURE 35.
SERVICE
Before calling for repair service, read the "Start Up Conditions" and "Operational Conditions" found in the "For Your Information" section of this manual.
If a condition persists or you are uncertain about the operation of the water heater contact a service agency. If you are not thoroughly familiar with gas codes, your water heater, and safety practices, contact your gas supplier or qualified installer to check the water heater.
Use the”Leakage Checkpoints” guide to check a “Leaking” water heater. Many suspected “Leakers” are not leaking tanks. Often the source of the water can be found and corrected.
Read this manual first. Then before checking the water heater make sure the gas supply has been turned “OFF”, and never turn the gas “ON” before the tank is completely full of water.
Never use this water heater unless it is completely filled with water. To prevent damage to the tank, the tank must be filled with water. Water must flow from the hot water faucet before turning “ON” gas to the water heater.
26